Efficiency calibration and surface mapping of an energy-dispersive detector with SOLEX: A compact tunable monochromatic X-ray source

被引:11
|
作者
Menesguen, Y. [1 ]
Lepy, M. -C. [1 ]
机构
[1] CEA, LIST, LNHB, F-91191 Gif Sur Yvette, France
关键词
Energy-dispersive spectrometer; Efficiency calibration; X-ray source; SI(LI) DETECTOR; RANGE; RADIATION;
D O I
10.1016/j.nima.2011.11.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work presents the different measurement possibilities of the SOLEX facility for the characterization of an energy-dispersive detector. We first describe the SOLEX apparatus, its energy range and the internal proportional counter used for absolute flux measurement then we give an example of an energy-dispersive detector characterization. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [21] A fast energy-dispersive multi-element detector for X-ray absorption spectroscopy
    Welter, Edmund
    Hansen, Karsten
    Reckleben, Christian
    Diehl, Inge
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 293 - 298
  • [22] Depth-selective x-ray diffraction using energy-dispersive x-ray detector and straight capillary optics
    Fukumoto, Shotaro
    Okuda, Masaki
    Matsuyama, Tsugufumi
    Tsuji, Kouichi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (06):
  • [23] Synchrotron energy-dispersive X-ray diffraction tomography
    Hall, C
    Barnes, P
    Cockcroft, JK
    Colston, SL
    Hausermann, D
    Jacques, SDM
    Jupe, AC
    Kunz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 140 (1-2): : 253 - 257
  • [24] OPTIMUM RESOLUTION IN X-RAY ENERGY-DISPERSIVE DIFFRACTOMETRY
    BURAS, B
    NIIMURA, N
    OLSEN, JS
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1978, 11 (APR) : 137 - 140
  • [25] Application of x-ray optics to energy-dispersive spectroscopy
    McCarthy, JJ
    McMillan, DJ
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 632 - 639
  • [26] Measuring performance of energy-dispersive X-ray systems
    Statham, PJ
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 605 - 615
  • [27] Gauge of an energy-dispersive X-ray fluorescence analyzer
    Bukin, KV
    Nakhabtsev, VS
    Romanova, NE
    Kirillov, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 393 - 397
  • [29] FOCUSING X-RAY POLARIZER FOR ENERGY-DISPERSIVE ANALYSIS
    ONG, PS
    RANDALL, JN
    X-RAY SPECTROMETRY, 1978, 7 (04) : 241 - 248
  • [30] Rapid analysis for the arsenic limit test by energy-dispersive X-ray fluorescence analysis with monochromatic excitation
    Wakisaka, T
    Morita, N
    Tanaka, S
    Nakahara, T
    BUNSEKI KAGAKU, 1996, 45 (11) : 1019 - 1023