Improved Reduction of the Tibiofibular Syndesmosis With TightRope Compared With Screw Fixation: Results of a Randomized Controlled Study

被引:55
|
作者
Sanders, David [1 ,8 ]
Schneider, Prism [2 ,3 ]
Taylor, Michel [1 ,8 ]
Tieszer, Christina [1 ,8 ]
Lawendy, Abdel-Rahman [1 ,8 ]
Duffy, Paul [3 ]
Buckley, Rick [3 ]
Korley, Robert [3 ]
Martin, C. Ryan [3 ]
Carcary, Kimberly [3 ]
McKercher, Ross [3 ]
Yee, Stephanie [3 ]
Harrison, Tanja [3 ]
Schultz, Leah [3 ]
Akbari, Aftab [3 ]
Papp, Steven [4 ]
Gofton, Wade [4 ]
Liew, Allan [4 ]
Lalonde, Karl [4 ]
Foxall, Julia [4 ]
Harris, Nicole [4 ]
Champagne, Philippe-Hugo [5 ]
Balg, Frederic [5 ]
Deshaies, Annie [5 ]
LaRue, Bernard [5 ]
Patenaude, Nicolas [5 ]
Joncas, Jean-Francois [5 ]
Vezina, Francois [5 ]
Ricard, Stephanie [5 ]
Magalhaes, Marc-Andre [5 ]
Svotelis, Amy [5 ]
Lebel, Karina [5 ]
Bedard, Sonia [5 ]
Raynauld, Catherine [5 ]
Apostle, Kelly [6 ]
Viskontas, Darius [6 ]
Stone, Trevor [6 ]
Moola, Farhad [6 ]
Perey, Bertrand [6 ]
Boyer, Dory [6 ]
Lemke, Michael [6 ]
Zomar, Mauri [6 ]
Moon, Karyn [6 ]
Moon, Raely [6 ]
Leighton, Ross [7 ]
Coles, Chad [7 ]
Dunbar, Michael [7 ]
Glazebrook, Mark [7 ]
Coady, Cathy [7 ]
Trenholm, Andrew [7 ]
机构
[1] Victoria Hosp, London Hlth Sci Ctr, Dept Orthoped Surg, London, ON, Canada
[2] Foothills Med Ctr, Dept Orthoped Surg, Calgary, AB, Canada
[3] Foothills Med Ctr, Orthoped Surg, 3134 Hosp Dr, Calgary, AB T2N 5A1, Canada
[4] Ottawa Hosp, Orthoped Surg, Civ Campus,1053 Carling Ave, Ottawa, ON K1Y 4E9, Canada
[5] CHUS, Orthoped Surg, 3001,12e Ave N, Sherbrooke, PQ J1H 5N4, Canada
[6] Royal Columbian Hosp, Fraser Hlth Author, Orthoped Surg, 330 East Columbia St, New Westminster, BC V3L 3W7, Canada
[7] Queen Elizabeth 2 Hlth Sci Ctr, Orthoped Surg, STE 4875 Halifax Infirm Site,1796 Summers St, Halifax, NS B3H 3A7, Canada
[8] Victoria Hosp, London Hlth Sci Ctr, Orthoped Surg, 800 Commissioners Rd E, London, ON N6A 4G5, Canada
[9] Peter Lougheed Ctr, Orthoped Surg, 3500 26 Ave, Calgary, AB T1Y 6J4, Canada
[10] South Hlth Campus, Orthoped Surg, 4448 Front St SE, Calgary, AB T3M 1M4, Canada
[11] St Michaels Hosp, Orthoped Surg, 55 Queen St E, Toronto, ON M5C 1R6, Canada
[12] Hamilton Hlth Sci Ctr, Orthoped Surg, 293 Wellington St N, Hamilton, ON L8L 8E7, Canada
[13] Sunnybrook Hlth Sci Ctr, Orthoped Surg, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
关键词
Tibiofibular syndesmosis; TightRope; reduction; functional outcomes; CT scan; SUTURE-BUTTON; ANKLE; CONSTRUCT; INJURY; FOOT; MALREDUCTION; RELIABILITY; VALIDITY; OUTCOMES; EUROQOL;
D O I
10.1097/BOT.0000000000001559
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare the rate of malreduction after high fibular fractures associated with syndesmosis injury treated with open reduction and internal fixation, with either 2 screws or 1 knotless TightRope device. Design: Prospective randomized controlled multicenter trial. Setting: Eleven academic and community hospitals including Level 1 and Level 2 trauma centers across Canada. Patients/Participants: One hundred three patients with OTA/AO 44-C injuries with demonstrated radiographic syndesmosis diastasis or instability after malleolar bony fixation were followed for 12 months after treatment. Methods: Open reduction of the syndesmosis was performed in all cases. Fixation was randomized to either TightRope (1 knotless TightRope, group T) or screw fixation (two 3.5-mm cortical positional screws placed across 3 cortices, group S). Surgical techniques and rehabilitation were standardized. All surgeons were trained or experienced in the use of the TightRope device. Follow-up was performed at 2 and 6 weeks, 3, 6, and 12 months. Main Outcome Measure: Rate of malreduction based on bilateral ankle computed tomography scan results at 3 months after fixation. Secondary outcome measures included adverse events, reoperation, and validated functional outcomes including the EQ-5D, the Olerud-Molander Ankle Score, the Foot and Ankle Disability Index, and the Work Productivity Activity Impairment Questionnaire. The estimated sample size required to detect a difference in reduction rate was 72 patients, but the estimated sample size required to detect a difference in functional outcome scores was 240 patients, suggesting the study was adequately powered for radiographic results only. Results: Overall, the rate of malreduction using screw fixation was 39% compared with 15% using TightRope fixation (P = 0.028, chi(2)). Analysis of computed tomography results was performed using a 2-mm translation or 10-degree rotation threshold for malreduction and included fibular translation (anterior, posterior); syndesmosis distance (anterior, posterior, and mid); medial compression; and rotation (fibular and articular). Patients in group T had greater anterior translation (5.4 +/- 1.8 mm) compared with the contralateral limb (4.3 +/- 1.3 mm, P < 0.01) or group S (4.6 +/- 1.5 mm, P = 0.05). Group T syndesmoses also had greater diastasis compared with control limb (4.1 +/- 1.3 vs. 3.3 +/- 1.4 mm, P < 0.01) and less fibular medialization compared with group S (1.04 +/- 1.8 vs. 0.3 +/- 1.8 mm, P = 0.05). Functional outcome measures demonstrated significant improvements over time, but no differences between fixation groups. Foot and Ankle Disability Index scores at each time interval were 44 +/- 22 (T) versus 45 +/- 24 (S) (6 weeks), 76 +/- 14 versus 73 +/- 17 (3 months), 89 +/- 10 versus 86 +/- 13 (6 months), and 93 +/- 9 versus 90 +/- 14 (12 months) (all P > 0.2). The reoperation rate was higher in the screw group compared with TightRope (30% vs. 4%, P = 0.02) with the difference driven by the rate of implant removal. Conclusions: Based on our results, the TightRope device seems to compare favorably with two, 3.5-mm, 3-cortex screw fixation for syndesmosis injuries.
引用
收藏
页码:531 / 537
页数:7
相关论文
共 50 条
  • [41] Dynamic hip screw compared with external fixation for treatment of osteoporotic pertrochanteric fractures - A prospective, randomized study
    Moroni, A
    Faldini, C
    Pegreffi, F
    Hoang-Kim, A
    Vannini, F
    Giannini, S
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (04): : 753 - 759
  • [42] Suture Button Versus Syndesmotic Screw for Syndesmosis Injuries: A Meta-analysis of Randomized Controlled Trials
    Shimozono, Yoshiharu
    Hurley, Eoghan T.
    Myerson, C. Lucas
    Murawski, Christopher D.
    Kennedy, John G.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (11): : 2764 - 2771
  • [43] Transcortical Screw Fixation of the Olecranon Shows Equivalent Strength and Improved Stability Compared With Tension Band Fixation
    Jones, Tyler B.
    Karenz, Andrew R.
    Weinhold, Paul S.
    Dahners, Laurence E.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (03) : 137 - 142
  • [44] No Difference in Functional and Radiographic Results 8.4 Years After Quadricortical Compared With Tricortical Syndesmosis Fixation in Ankle Fractures
    Wikeroy, Annette K. B.
    Hoiness, Per R.
    Andreassen, Geir S.
    Hellund, Johan C.
    Madsen, Jan Erik
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (01) : 17 - 23
  • [45] Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: A prospective randomized trial
    Thordarson, DB
    Samuelson, M
    Shepherd, LE
    Merkle, PF
    Lee, J
    FOOT & ANKLE INTERNATIONAL, 2001, 22 (04) : 335 - 338
  • [46] A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury A retrospective cohort study
    Kurtoglu, Alper
    Kochai, Alauddin
    Inanmaz, Mustafa Erkan
    Sukur, Erhan
    Keskin, Dogan
    Turker, Mehmet
    Uysal, Mustafa
    Sen, Zafer
    Daldal, Ismail
    MEDICINE, 2021, 100 (13) : E25328
  • [47] Dynamic Fixation versus Static Screw Fixation for Syndesmosis Injuries in Pronation External Rotation Ankle Fractures: A Retrospective Case Control Study
    Lim, C. M.
    Choi, S. W.
    Kim, B. S.
    Lee, S. J.
    Kang, H. S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2023, 17 (03) : 48 - 58
  • [48] Suture-button fixation and anterior inferior tibiofibular ligament augmentation with suture-tape for syndesmosis injury: A biomechanical cadaveric study
    Shoji, Hiroaki
    Teramoto, Atsushi
    Suzuki, Daisuke
    Okada, Yohei
    Sakakibara, Yuzuru
    Matsumura, Takashi
    Suzuki, Tomoyuki
    Watanabe, Kota
    Yamashita, Toshihiko
    CLINICAL BIOMECHANICS, 2018, 60 : 121 - 126
  • [49] Gotfried Percutaneous Compression Plating Compared with Sliding Hip Screw Fixation of Intertrochanteric Hip Fractures A Prospective Randomized Study
    Yang, Edward
    Qureshi, Sheeraz
    Trokhan, Shawn
    Joseph, David
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (10): : 942 - 947
  • [50] CT-controlled results after screw fixation of acute scaphoid fractures
    Müller, M
    Chen, ZB
    al Morshidy, A
    Germann, G
    Sauerbier, M
    UNFALLCHIRURG, 2006, 109 (03): : 185 - 192