Improved Reduction of the Tibiofibular Syndesmosis With TightRope Compared With Screw Fixation: Results of a Randomized Controlled Study

被引:55
|
作者
Sanders, David [1 ,8 ]
Schneider, Prism [2 ,3 ]
Taylor, Michel [1 ,8 ]
Tieszer, Christina [1 ,8 ]
Lawendy, Abdel-Rahman [1 ,8 ]
Duffy, Paul [3 ]
Buckley, Rick [3 ]
Korley, Robert [3 ]
Martin, C. Ryan [3 ]
Carcary, Kimberly [3 ]
McKercher, Ross [3 ]
Yee, Stephanie [3 ]
Harrison, Tanja [3 ]
Schultz, Leah [3 ]
Akbari, Aftab [3 ]
Papp, Steven [4 ]
Gofton, Wade [4 ]
Liew, Allan [4 ]
Lalonde, Karl [4 ]
Foxall, Julia [4 ]
Harris, Nicole [4 ]
Champagne, Philippe-Hugo [5 ]
Balg, Frederic [5 ]
Deshaies, Annie [5 ]
LaRue, Bernard [5 ]
Patenaude, Nicolas [5 ]
Joncas, Jean-Francois [5 ]
Vezina, Francois [5 ]
Ricard, Stephanie [5 ]
Magalhaes, Marc-Andre [5 ]
Svotelis, Amy [5 ]
Lebel, Karina [5 ]
Bedard, Sonia [5 ]
Raynauld, Catherine [5 ]
Apostle, Kelly [6 ]
Viskontas, Darius [6 ]
Stone, Trevor [6 ]
Moola, Farhad [6 ]
Perey, Bertrand [6 ]
Boyer, Dory [6 ]
Lemke, Michael [6 ]
Zomar, Mauri [6 ]
Moon, Karyn [6 ]
Moon, Raely [6 ]
Leighton, Ross [7 ]
Coles, Chad [7 ]
Dunbar, Michael [7 ]
Glazebrook, Mark [7 ]
Coady, Cathy [7 ]
Trenholm, Andrew [7 ]
机构
[1] Victoria Hosp, London Hlth Sci Ctr, Dept Orthoped Surg, London, ON, Canada
[2] Foothills Med Ctr, Dept Orthoped Surg, Calgary, AB, Canada
[3] Foothills Med Ctr, Orthoped Surg, 3134 Hosp Dr, Calgary, AB T2N 5A1, Canada
[4] Ottawa Hosp, Orthoped Surg, Civ Campus,1053 Carling Ave, Ottawa, ON K1Y 4E9, Canada
[5] CHUS, Orthoped Surg, 3001,12e Ave N, Sherbrooke, PQ J1H 5N4, Canada
[6] Royal Columbian Hosp, Fraser Hlth Author, Orthoped Surg, 330 East Columbia St, New Westminster, BC V3L 3W7, Canada
[7] Queen Elizabeth 2 Hlth Sci Ctr, Orthoped Surg, STE 4875 Halifax Infirm Site,1796 Summers St, Halifax, NS B3H 3A7, Canada
[8] Victoria Hosp, London Hlth Sci Ctr, Orthoped Surg, 800 Commissioners Rd E, London, ON N6A 4G5, Canada
[9] Peter Lougheed Ctr, Orthoped Surg, 3500 26 Ave, Calgary, AB T1Y 6J4, Canada
[10] South Hlth Campus, Orthoped Surg, 4448 Front St SE, Calgary, AB T3M 1M4, Canada
[11] St Michaels Hosp, Orthoped Surg, 55 Queen St E, Toronto, ON M5C 1R6, Canada
[12] Hamilton Hlth Sci Ctr, Orthoped Surg, 293 Wellington St N, Hamilton, ON L8L 8E7, Canada
[13] Sunnybrook Hlth Sci Ctr, Orthoped Surg, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
关键词
Tibiofibular syndesmosis; TightRope; reduction; functional outcomes; CT scan; SUTURE-BUTTON; ANKLE; CONSTRUCT; INJURY; FOOT; MALREDUCTION; RELIABILITY; VALIDITY; OUTCOMES; EUROQOL;
D O I
10.1097/BOT.0000000000001559
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare the rate of malreduction after high fibular fractures associated with syndesmosis injury treated with open reduction and internal fixation, with either 2 screws or 1 knotless TightRope device. Design: Prospective randomized controlled multicenter trial. Setting: Eleven academic and community hospitals including Level 1 and Level 2 trauma centers across Canada. Patients/Participants: One hundred three patients with OTA/AO 44-C injuries with demonstrated radiographic syndesmosis diastasis or instability after malleolar bony fixation were followed for 12 months after treatment. Methods: Open reduction of the syndesmosis was performed in all cases. Fixation was randomized to either TightRope (1 knotless TightRope, group T) or screw fixation (two 3.5-mm cortical positional screws placed across 3 cortices, group S). Surgical techniques and rehabilitation were standardized. All surgeons were trained or experienced in the use of the TightRope device. Follow-up was performed at 2 and 6 weeks, 3, 6, and 12 months. Main Outcome Measure: Rate of malreduction based on bilateral ankle computed tomography scan results at 3 months after fixation. Secondary outcome measures included adverse events, reoperation, and validated functional outcomes including the EQ-5D, the Olerud-Molander Ankle Score, the Foot and Ankle Disability Index, and the Work Productivity Activity Impairment Questionnaire. The estimated sample size required to detect a difference in reduction rate was 72 patients, but the estimated sample size required to detect a difference in functional outcome scores was 240 patients, suggesting the study was adequately powered for radiographic results only. Results: Overall, the rate of malreduction using screw fixation was 39% compared with 15% using TightRope fixation (P = 0.028, chi(2)). Analysis of computed tomography results was performed using a 2-mm translation or 10-degree rotation threshold for malreduction and included fibular translation (anterior, posterior); syndesmosis distance (anterior, posterior, and mid); medial compression; and rotation (fibular and articular). Patients in group T had greater anterior translation (5.4 +/- 1.8 mm) compared with the contralateral limb (4.3 +/- 1.3 mm, P < 0.01) or group S (4.6 +/- 1.5 mm, P = 0.05). Group T syndesmoses also had greater diastasis compared with control limb (4.1 +/- 1.3 vs. 3.3 +/- 1.4 mm, P < 0.01) and less fibular medialization compared with group S (1.04 +/- 1.8 vs. 0.3 +/- 1.8 mm, P = 0.05). Functional outcome measures demonstrated significant improvements over time, but no differences between fixation groups. Foot and Ankle Disability Index scores at each time interval were 44 +/- 22 (T) versus 45 +/- 24 (S) (6 weeks), 76 +/- 14 versus 73 +/- 17 (3 months), 89 +/- 10 versus 86 +/- 13 (6 months), and 93 +/- 9 versus 90 +/- 14 (12 months) (all P > 0.2). The reoperation rate was higher in the screw group compared with TightRope (30% vs. 4%, P = 0.02) with the difference driven by the rate of implant removal. Conclusions: Based on our results, the TightRope device seems to compare favorably with two, 3.5-mm, 3-cortex screw fixation for syndesmosis injuries.
引用
收藏
页码:531 / 537
页数:7
相关论文
共 50 条
  • [21] Effects of inferior tibiofibular syndesmosis injury and screw stabilization on motion of the ankle: a finite element study
    Qinghua Liu
    Guanghui Zhao
    Bin Yu
    Jianbin Ma
    Zhong Li
    Kun Zhang
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 1228 - 1235
  • [22] Comparison the treatment of anterior inferior tibiofibular ligament anatomical repair and syndesmosis screw fixation for syndesmotic injuries in ankle fracture
    Lin, Xuping
    Tu, Chengquan
    Lin, Weihuang
    Xie, Weina
    Guo, Xiaowei
    Liu, Qingjun
    BMC SURGERY, 2023, 23 (01)
  • [23] Comparison the treatment of anterior inferior tibiofibular ligament anatomical repair and syndesmosis screw fixation for syndesmotic injuries in ankle fracture
    Xuping Lin
    Chengquan Tu
    Weihuang Lin
    Weina Xie
    Xiaowei Guo
    Qingjun Liu
    BMC Surgery, 23
  • [24] The Clinical Efficacy of Suture-Button Fixation and Trans-Syndesmotic Screw Fixation in the Treatment of Ankle Fracture Combined With Distal Tibiofibular Syndesmosis Injury: A Retrospective Study
    Xu, Yibo
    Kang, Ran
    Li, Ming
    Li, Zhong
    Ma, Teng
    Ren, Cheng
    Wang, Qian
    Lu, Yao
    Zhang, Kun
    JOURNAL OF FOOT & ANKLE SURGERY, 2022, 61 (01): : 143 - 148
  • [25] Dynamics of tibiofibular syndesmosis in correlation with the level of the syndesmotic screw in maisonneuve fractures of the ankle - A cadaver study
    Mousavi M.
    Egkher A.
    Pichl W.
    Kubiena H.
    Kolonja A.
    Egkher E.
    Vécsei V.
    European Journal of Trauma, 2001, 27 (2): : 87 - 91
  • [26] Effects of inferior tibiofibular syndesmosis injury and screw stabilization on motion of the ankle: a finite element study
    Liu, Qinghua
    Zhao, Guanghui
    Yu, Bin
    Ma, Jianbin
    Li, Zhong
    Zhang, Kun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (04) : 1228 - 1235
  • [27] Differences in gait analysis and clinical outcome after dynamic fixation or screw fixation in acute syndesmosis tear: a prospective randomized pilot study
    Mick, Paul
    Doll, Julian
    Mueller, Michelle
    Schmidmaier, Gerhard
    Renkawitz, Tobias
    Campos, Sarah
    Wolf, Sebastian I.
    Tsitlakidis, Stefanos
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4355 - 4363
  • [28] Radiographic Evaluation of Syndesmosis Stabilisation Using the TightRope System Versus Syndesmotic Screw Fixation for the Management of Ankle Fractures With a Syndesmotic Injury
    Saraglis, Georgios
    Khan, Anwar
    Chaudhari, Harsh
    Pyakurel, Sagar
    Rabbani, Sayed Fazal Elahi
    Arafa, Mohamed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [29] Tricortical versus quadricortical syndesmosis fixation in ankle fractures - A prospective, randomized study comparing two methods of syndesmosis fixation
    Hoiness, P
    Stromsoe, K
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (06) : 331 - 337
  • [30] Effect of a Dynamic Fixation Construct on Syndesmosis Reduction: A Cadaveric Study
    Honeycutt, M. Wesley
    Riehl, John T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (09) : 460 - 464