COMPARATIVE EVALUATION OF A TWO-STAGE REFRIGERATION SYSTEM WITH FLASH INTERCOOLING USING DIFFERENT REFRIGERANTS

被引:1
|
作者
Mancuhan, Ebru [1 ]
机构
[1] Marmara Univ, Istanbul, Turkey
来源
THERMAL SCIENCE | 2020年 / 24卷 / 02期
关键词
optimization; low temperature applications; COP; Second law efficiency; exergy loss; THERMODYNAMIC ANALYSIS; TEMPERATURE; PRESSURE;
D O I
10.2298/TSCI180921011M
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of this study is to investigate the effect of low global warming potential refrigerants on the optimum intermediate pressure (P-OPT,P-int) and performance (COP) values of a refrigeration system with flash intercooling. For realize, the optimum operating parameters of system were determined in low temperature applications through a theoretical analysis according to the different refrigerants (R290, R404A, R407C, R507A, and R22). The theoretical modelling ofsystem is done by optimizing the intermediate pressure at given evaporation (T-E) and condensation (T-C) temperatures for selected refrigerants. After optimization, the maximized values of COP and Second law efficiency are computed from the predicted values of P-OPT,P-int. The linear regression method is then used to derive three correlations of P-OPT,P-int, maximum values of COP and Second law efficiency according to T-E and T-C Hence, the P-OPT,P-int values maximizing the system performance are found from various T-E and T-C values for each refrigerant. Due to calculations, increasing T-E and T-C cause the increase in P-OPT,P-int in low temperature applications. The R507A system has the highest P-OPT,P-int values and R22 system has the lowest P-OPT,P-int values. Although R22 system has slightly more efficient than R290 system, it is being phased out world-wide because of the risk of ozone depletion potential and global warming potential considerations. Therefore, it is important to evaluate the R22 replacement options. The R290 was discovered to have better performance than the R404A, R407C and R507A systems in terms of COPmax(1.81), global warming potential (11), and ozone depletion potential (0) when T-E and T-C are -35 degrees C and 40 degrees C.
引用
收藏
页码:815 / 830
页数:16
相关论文
共 50 条
  • [41] Multiobjective optimization based on mixed refrigerants and different two-stage vapor injection systems
    Zhao, Xiangming
    Guo, Jianxiang
    He, Maogang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 147 : 143 - 151
  • [42] Refrigeration Efficient Refrigeration for the Industry A two-stage system ensures quality and reduces energy consumption
    Lukas, Detlev A.
    FLEISCHWIRTSCHAFT, 2011, 91 (04): : 51 - 52
  • [43] Experimental study on two-stage ejector refrigeration system driven by two heat sources
    Chen, Guangming
    Zhang, Rongtao
    Zhu, Daibin
    Chen, Shaojie
    Fang, Lingyun
    Hao, Xinyue
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 295 - 303
  • [44] R744-R717 Cascade Refrigeration System: Performance Evaluation compared with a HFC Two-Stage System
    Messineo, Antonio
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 56 - 65
  • [45] HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature
    Llopis, R.
    Torrella, E.
    Cabello, R.
    Sanchez, D.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04): : 810 - 816
  • [46] Effects of Internal Heat Exchanger on Two-Stage Compression Trans-Critical CO2 Refrigeration Cycle Combined with Expander and Intercooling
    Shi, Benlin
    Chen, Muqing
    Chi, Weikai
    Yang, Qichao
    Liu, Guangbin
    Zhao, Yuanyang
    Li, Liansheng
    ENERGIES, 2023, 16 (01)
  • [47] ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    JOURNAL OF THERMAL ENGINEERING, 2015, 1 (04): : 440 - 445
  • [48] Theoretical performance of tratiscritical carbon dioxide cycle with two-stage compression and intercooling
    Baek, JS
    Groll, EA
    Lawless, B
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2005, 219 (E2) : 187 - 195
  • [49] Performance Analysis of a Carbon Dioxide Transcritical Two-Stage Compression Refrigeration System
    Wei, Zhiyong
    Wang, Jinfeng
    Xie, Jing
    Xu, Hao
    Wu, Chenlong
    Ye, Guosen
    Jiang, Jilin
    Han, Xinrong
    NEW ENERGY AND FUTURE ENERGY SYSTEMS, NEFES 2023, 2023, 45 : 92 - 102
  • [50] Optimum performance analysis of a two-stage irreversible magnetization Brayton refrigeration system
    Zhang, Yue
    Lin, Bihong
    Chen, Jincan
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (20) : 4293 - 4298