COMPARATIVE EVALUATION OF A TWO-STAGE REFRIGERATION SYSTEM WITH FLASH INTERCOOLING USING DIFFERENT REFRIGERANTS

被引:1
|
作者
Mancuhan, Ebru [1 ]
机构
[1] Marmara Univ, Istanbul, Turkey
来源
THERMAL SCIENCE | 2020年 / 24卷 / 02期
关键词
optimization; low temperature applications; COP; Second law efficiency; exergy loss; THERMODYNAMIC ANALYSIS; TEMPERATURE; PRESSURE;
D O I
10.2298/TSCI180921011M
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of this study is to investigate the effect of low global warming potential refrigerants on the optimum intermediate pressure (P-OPT,P-int) and performance (COP) values of a refrigeration system with flash intercooling. For realize, the optimum operating parameters of system were determined in low temperature applications through a theoretical analysis according to the different refrigerants (R290, R404A, R407C, R507A, and R22). The theoretical modelling ofsystem is done by optimizing the intermediate pressure at given evaporation (T-E) and condensation (T-C) temperatures for selected refrigerants. After optimization, the maximized values of COP and Second law efficiency are computed from the predicted values of P-OPT,P-int. The linear regression method is then used to derive three correlations of P-OPT,P-int, maximum values of COP and Second law efficiency according to T-E and T-C Hence, the P-OPT,P-int values maximizing the system performance are found from various T-E and T-C values for each refrigerant. Due to calculations, increasing T-E and T-C cause the increase in P-OPT,P-int in low temperature applications. The R507A system has the highest P-OPT,P-int values and R22 system has the lowest P-OPT,P-int values. Although R22 system has slightly more efficient than R290 system, it is being phased out world-wide because of the risk of ozone depletion potential and global warming potential considerations. Therefore, it is important to evaluate the R22 replacement options. The R290 was discovered to have better performance than the R404A, R407C and R507A systems in terms of COPmax(1.81), global warming potential (11), and ozone depletion potential (0) when T-E and T-C are -35 degrees C and 40 degrees C.
引用
收藏
页码:815 / 830
页数:16
相关论文
共 50 条
  • [31] Two-stage cascade configurations based on ejectors for ultra-low temperature refrigeration with natural refrigerants
    Udroiu C.-M.
    Mota-Babiloni A.
    Giménez-Prades P.
    Barragán-Cervera Á.
    Navarro-Esbrí J.
    International Journal of Thermofluids, 2023, 17
  • [32] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi 'an
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [33] Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration
    Sun, Zhili
    Wang, Yi'An
    Case Studies in Thermal Engineering, 2022, 39
  • [34] Design and performance analysis of two-stage ejector for the subzero refrigeration system
    Song Y.
    Wang X.
    Wang L.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (09): : 34 - 43
  • [35] Characteristics of two-stage segregation auto-cascade refrigeration system
    Rui, Shengjun
    Zhang, Hua
    Zhang, Qinggang
    Huang, Lihao
    Huagong Xuebao/CIESC Journal, 2013, 64 (06): : 2029 - 2035
  • [36] Application of exergy method to a two-stage irreversible combined refrigeration system
    Su, Y-F
    Chen, C-K
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2007, 221 (07) : 807 - 813
  • [37] A comparison of refrigerants in a two-stage ejector-expansion transcritical refrigeration cycle based on exergoeconomic and environmental analysis
    Nemati, Arash
    Nami, Hossein
    Yari, Mortaza
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 139 - 150
  • [38] Energy and exergy analyses of a two-stage vapour compression refrigeration system
    Arora, Akhilesh
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (10) : 907 - 923
  • [39] Performance analysis of a two-stage ejector in an ejector refrigeration system using computational fluid dynamics
    Suvarnakuta, N.
    Pianthong, K.
    Sriveerakul, T.
    Seehanam, W.
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2020, 14 (01) : 669 - 682
  • [40] Design and rating of a two-stage vapor-compression refrigeration system
    Khan, JUR