COMPARATIVE EVALUATION OF A TWO-STAGE REFRIGERATION SYSTEM WITH FLASH INTERCOOLING USING DIFFERENT REFRIGERANTS

被引:1
|
作者
Mancuhan, Ebru [1 ]
机构
[1] Marmara Univ, Istanbul, Turkey
来源
THERMAL SCIENCE | 2020年 / 24卷 / 02期
关键词
optimization; low temperature applications; COP; Second law efficiency; exergy loss; THERMODYNAMIC ANALYSIS; TEMPERATURE; PRESSURE;
D O I
10.2298/TSCI180921011M
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of this study is to investigate the effect of low global warming potential refrigerants on the optimum intermediate pressure (P-OPT,P-int) and performance (COP) values of a refrigeration system with flash intercooling. For realize, the optimum operating parameters of system were determined in low temperature applications through a theoretical analysis according to the different refrigerants (R290, R404A, R407C, R507A, and R22). The theoretical modelling ofsystem is done by optimizing the intermediate pressure at given evaporation (T-E) and condensation (T-C) temperatures for selected refrigerants. After optimization, the maximized values of COP and Second law efficiency are computed from the predicted values of P-OPT,P-int. The linear regression method is then used to derive three correlations of P-OPT,P-int, maximum values of COP and Second law efficiency according to T-E and T-C Hence, the P-OPT,P-int values maximizing the system performance are found from various T-E and T-C values for each refrigerant. Due to calculations, increasing T-E and T-C cause the increase in P-OPT,P-int in low temperature applications. The R507A system has the highest P-OPT,P-int values and R22 system has the lowest P-OPT,P-int values. Although R22 system has slightly more efficient than R290 system, it is being phased out world-wide because of the risk of ozone depletion potential and global warming potential considerations. Therefore, it is important to evaluate the R22 replacement options. The R290 was discovered to have better performance than the R404A, R407C and R507A systems in terms of COPmax(1.81), global warming potential (11), and ozone depletion potential (0) when T-E and T-C are -35 degrees C and 40 degrees C.
引用
收藏
页码:815 / 830
页数:16
相关论文
共 50 条
  • [1] A comprehensive comparison between low and medium temperature application refrigerants at a two-stage refrigeration system with flash intercooling
    Mancuhan, Ebru
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 13
  • [2] COMPARISON OF DIFFERENT REFRIGERANTS FOR A TWO-STAGE TRANSPORT REFRIGERATION SYSTEM
    Moehlenkamp, A.
    Lemke, N.
    Koehler, J.
    3RD IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2014, 2014 (01): : 676 - 686
  • [3] Performance analysis on two-stage and binary cascade refrigeration system using substitute refrigerants
    Zhao, HX
    Liu, SG
    Ma, GY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 492 - 498
  • [4] Theoretical performance comparison for two-stage auto-cascade refrigeration system using hydrocarbon refrigerants
    He, Yongning
    Wu, Huihong
    Liu, Yingying
    Wang, Tao
    Wu, Xuehong
    Cheng, Chuanxiao
    Jin, Tingxiang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 142 : 27 - 36
  • [5] THEORETICAL ANALYSIS ON THE PREDICTION OF PERFORMANCE COEFFICIENT OF TWO-STAGE CASCADE REFRIGERATION SYSTEM USING VARIOUS ALTERNATIVE REFRIGERANTS
    Dalkilic, Ahmet Selim
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2012, 32 (01) : 67 - 79
  • [6] Thermodynamic evaluation of two-stage refrigeration cycle with deep intercooling and series-parallel integration of thermal and mechanical compression
    Wang, Ruiting
    Li, Zeyu
    Peng, Zeyu
    Huang, Caoxuheng
    Ye, Zhihao
    Yu, Jianting
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2023, 20 (14) : 1628 - 1648
  • [7] Energy, exergy, economic and environmental analyses of a cascade absorption-compression refrigeration system using two-stage compression with complete intercooling
    Zhang, Hanyue
    Pan, Xi
    Chen, Jianye
    Xie, Junlong
    APPLIED THERMAL ENGINEERING, 2023, 225
  • [8] Studies on a two-stage transcritical carbon dioxide heat pump cycle with flash intercooling
    Agrawal, Neeraj
    Bhattacharyya, Souvik
    APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 299 - 305
  • [9] Comparative Study on Two-Stage Absorption Refrigeration Systems with Different Working Pairs
    Kong X.
    Meng X.
    Li J.
    Shang Y.
    Cui F.
    Journal of Shanghai Jiaotong University (Science), 2021, 26 (2) : 155 - 162
  • [10] Investigation on a two-stage ejection refrigeration system
    He, Yijian
    Chen, Zuozhou
    Tang, Liming
    Chen, Guangming
    APPLIED THERMAL ENGINEERING, 2015, 86 : 49 - 59