Automated Daily Quality Assurance of Medical Digital X-Ray Equipment

被引:0
|
作者
Zelikman, Mikhail [1 ]
Kruchinin, Sergey [1 ]
机构
[1] Res & Pract Ctr Med Radiol, Moscow 109029, Russia
关键词
digital x-ray equipment; quality assurance; routine test; test-object;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine test in automated mode.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] X-RAY RADIOGRAPHY WITH X-RAY DIFFRACTION EQUIPMENT
    CLIFTON, HE
    JOURNAL OF SEDIMENTARY PETROLOGY, 1966, 36 (02): : 620 - &
  • [42] QUALITY CONTROL TESTING OF X-RAY EQUIPMENT USED IN MEDICAL DIAGNOSTIC: RESULTS OF INTERLABORATORY COMPARISON
    Brodecki, Marcin
    Bednarek, Andrzej
    Janiak, Przemyslaw
    Zmyslony, Marek
    MEDYCYNA PRACY, 2012, 63 (03) : 345 - 354
  • [43] A comparison of the quality of images of chest X-ray between handheld portable digital X-ray & routinely used digital X-ray machine
    Kamal, Raj
    Singh, Manjula
    Roy, Sudipto
    Adhikari, Tulsi
    Gupta, Anil Kumar
    Singh, Hari
    Rao, Vishnu Vardhan
    Panda, Samiran
    Khan, A. M.
    Bhargava, Balram
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2023, 157 (02) : 204 - 210
  • [44] Problems of Enhancement of Diagnostic Capacity of Medical X-Ray Equipment
    Blinov N.N.
    Mazurov A.I.
    Biomedical Engineering, 2011, 45 (5) : 157 - 161
  • [45] Minimum requirements for medical X-ray equipment for donation to NGOs
    Luis Gonzalez-Alonso, Jose
    DYNA, 2009, 84 (01): : 58 - 63
  • [46] MEDICAL EQUIPMENT QUALITY ASSURANCE FOR HEALTHCARE FACILITIES
    Medhat, N.
    Samy, S. A.
    Wahed, M. Abdel
    Mohamed, A. S. A.
    2008 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE, 2008, : 304 - 307
  • [47] New version of the guidelines of the German Medical Association for quality assurance in X-ray diagnostics and computed tomography
    Loose, Reinhard
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (02): : 166 - 166
  • [48] SEMINAR ON METHODS FOR QUALITY ASSURANCE IN MEDICAL X-RAY-DIAGNOSIS
    不详
    PTB-MITTEILUNGEN, 1984, 94 (05): : 356 - 357
  • [49] Automated X-Ray Quality Control of Catalytic Converters
    Shashishekhar, N.
    Veselitza, D.
    43RD REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, 2017, 1806
  • [50] Cloud Based Monitoring of X-Ray Angiography Equipment Performance Based On Automated Daily Sampling of Key Performance Indicators
    Sjoeberg, J.
    Omar, A.
    Bujila, R.
    Nowik, P.
    Olafsson, I.
    Poludniowski, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3670 - 3670