Catalytic converters are devices attached to the exhaust system of automobile or other engines to eliminate or substantially reduce polluting emissions. They consist of coated substrates enclosed in a stainless steel housing. The substrate is typically made of ceramic honeycombs; however stainless steel foil honeycombs are also used. The coating is usually a slurry of alumina, silica, rare earth oxides and platinum group metals. The slurry also known as the wash coat is applied to the substrate in two doses, one on each end of the substrate; in some cases multiple layers of coating are applied. X-ray imaging is used to inspect the applied coating depth on a substrate to confirm compliance with quality requirements. Automated image analysis techniques are employed to measure the coating depth from the X-ray image. Coating depth is assessed by analysis of attenuation line profiles in the image. Edge detection algorithms with noise reduction and outlier rejection are used to calculate the coating depth at a specified point along an attenuation line profile. Quality control of the product is accomplished using several attenuation line profile regions for coating depth measurements, with individual pass or fail criteria specified for each region.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Validation of Automated MTF Measurement for Digital X-Ray Imaging Quality Control
    Bey, A.
    MacLellan, C.
    Zhang, D.
    Palmer, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Efficient X-ray converters
    V. I. Bespalov
    V. V. Ryzhov
    I. Yu. Turchanovskii
    Technical Physics Letters, 1998, 24 : 20 - 21
  • [3] Efficient x-ray converters
    Bespalov, VI
    Ryzhov, VV
    Turchanovskii, IY
    TECHNICAL PHYSICS LETTERS, 1998, 24 (01) : 20 - 21
  • [4] QUALITY-CONTROL OF X-RAY EQUIPMENT
    CARRIER, R
    BEIQUE, RA
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 582 - 582
  • [5] Quality control and guarantee in X-ray diagnosis
    Polovchik, M.
    Medicinskaa radiologia, 1992, 37 (7-8): : 4 - 8
  • [6] QUALITY-CONTROL IN X-RAY DIVISIONS
    VANDERMERWE, EJ
    HEALTH PHYSICS, 1980, 38 (01): : 99 - 99
  • [7] Quality and parameter control of X-ray absorption gratings by angular X-ray transmission
    Gustschin, Nikolai
    Gustschin, Alex
    Meyer, Pascal
    Viermetz, Manuel
    Riederer, Philipp
    Herzen, Julia
    Mohr, Juergen
    Pfeiffer, Franz
    OPTICS EXPRESS, 2019, 27 (11) : 15943 - 15955
  • [8] AUTOMATED X-RAY INSPECTION
    BUCHANAN, RA
    SAPIRSTEIN, RA
    MATERIALS EVALUATION, 1977, 35 (03) : S4 - S4
  • [9] Use of Handheld X-Ray Fluorescence to Analyze Platinum Group Metals in Catalytic Converters
    Paklin, Karen
    SPECTROSCOPY, 2019, 34 (06) : 26 - 31
  • [10] Quality control of commercial tea by x-ray fluorescence
    Salvador, MJ
    Lopes, GN
    Nascimento, VF
    Zucchi, OLAD
    X-RAY SPECTROMETRY, 2002, 31 (02) : 141 - 144