Hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering for high-speed gas-phase thermometry

被引:94
|
作者
Miller, Joseph D. [1 ]
Slipchenko, Mikhail N. [1 ,2 ]
Meyer, Terrence R. [1 ]
Stauffer, Hans U. [3 ]
Gord, James R. [3 ]
机构
[1] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[3] USAF, Res Lab, Prop Directorate, Wright Patterson AFB, OH 45433 USA
关键词
D O I
10.1364/OL.35.002430
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate hybrid femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman scattering for high-speed thermometry in unsteady high-temperature flames, including successful comparisons with a time-and frequency-resolved theoretical model. After excitation of the N(2) vibrational manifold with 100 fs broadband pump and Stokes beams, the Raman coherence is probed using a frequency-narrowed 2.5 ps probe beam that is time delayed to suppress the nonresonant background by 2 orders of magnitude. Experimental spectra were obtained at 500 Hz in steady and pulsed H(2)-air flames and exhibit a temperature precision of 2.2% and an accuracy of 3.3% up to 2400 K. Strategies for real-time gas-phase thermometry in high-temperature flames are also discussed, along with implications for kilohertz-rate measurements in practical combustion systems. (C) 2010 Optical Society of America
引用
收藏
页码:2430 / 2432
页数:3
相关论文
共 50 条
  • [41] Ethane thermometry using rotational coherent anti-Stokes Raman scattering (CARS)
    Hosseinnia, Ali
    Nordstrom, Emil
    Bood, Joakim
    Bengtsson, Per-Erik
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2017, 36 (03) : 4461 - 4468
  • [42] THE APPLICATION OF COHERENT ANTI-STOKES RAMAN-SCATTERING TO TURBULENT COMBUSTION THERMOMETRY
    GREENHALGH, DA
    PORTER, FM
    ENGLAND, WA
    COMBUSTION AND FLAME, 1983, 49 (1-3) : 171 - 181
  • [43] GAS CONCENTRATION MEASUREMENT BY COHERENT RAMAN ANTI-STOKES SCATTERING
    REGNIER, PR
    MOYA, F
    TARAN, JPE
    AIAA JOURNAL, 1974, 12 (06) : 826 - 831
  • [44] Polarization suppression of the nonresonant background in femtosecond coherent anti-Stokes Raman scattering for flame thermometry at 5 kHz
    Richardson, Daniel R.
    Bangar, Devashish
    Lucht, Robert P.
    OPTICS EXPRESS, 2012, 20 (19): : 21495 - 21504
  • [45] Phase Effects on Coherent Anti-Stokes Raman Light Scattering
    R. J. Kasumova
    N. V. Kerimli
    G. A. Safarova
    Journal of Applied Spectroscopy, 2021, 88 : 12 - 18
  • [46] Hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering temperature and concentration measurements using two different picosecond-duration probes
    Kearney, Sean P.
    Scoglietti, Daniel J.
    Kliewer, Christopher J.
    OPTICS EXPRESS, 2013, 21 (10): : 12327 - 12339
  • [47] PICOSECOND COHERENT ANTI-STOKES RAMAN-SCATTERING OF EXCITED-STATES
    PAYNE, SA
    HOCHSTRASSER, RM
    JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (10): : 2068 - 2074
  • [48] COHERENT ANTI-STOKES RAMAN-SCATTERING IN GASEOUS NITROGEN WITH PICOSECOND PULSES
    GREENE, BI
    WEISMAN, RB
    HOCHSTRASSER, RM
    CHEMICAL PHYSICS LETTERS, 1978, 59 (01) : 5 - 9
  • [49] Phase Control Strategies in Coherent Anti-Stokes Raman Scattering
    Gao, Fang
    Wei, Lingmin
    Shuang, Feng
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 7160 - 7165
  • [50] Phase Effects on Coherent Anti-Stokes Raman Light Scattering
    Kasumova, R. J.
    Kerimli, N. V.
    Safarova, G. A.
    JOURNAL OF APPLIED SPECTROSCOPY, 2021, 88 (01) : 12 - 18