Ceramic-on-ceramic implants in total hip arthroplasty

被引:1
|
作者
Colwell, C
D'Antonio, JA
Capello, WN
Hardwick, ME
机构
[1] Scripps Clin Ctr Orthopaed Res & Educ, La Jolla, CA 92107 USA
[2] Scripps Clin Ctr Orthopaed Res & Educ, Township, PA 15108 USA
[3] Scripps Clin Ctr Orthopaed Res & Educ, Indianapolis, IN 46202 USA
来源
BIOCERAMICS 17 | 2005年 / 284-286卷
关键词
alumina ceramic; total hip arthroplasty;
D O I
10.4028/www.scientific.net/KEM.284-286.1003
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Alumina ceramic is an excellent material for biologic implantation. Decreased particulate wear debris should increase implant longevity. The purpose of this study is to examine clinical and radiological results of ceramic-on-ceramic hip implants compared to cobalt chrome on polyethylene. Four cementless systems were compared, three alumina-on-alumina bearing systems: System I, porous coated cup; System II, hydroxyapatite-coated cup; Trident system, hydroxyapatite-coated cup with metal sleeve backing on ceramic cup liner; and System III (control), porous-coated cup with polyethylene and cobalt chromium bearing system. Patients were randomized to receive System I, II, or III. Trident patients were not randomized. Examinations are performed at 6 months, 1 year and yearly thereafter including x-rays, clinical exam and Harris Hip Score (HHS). Minimum 24-month followup was performed in 562 ceramic hips and 154 control hips. Age, height, weight, gender and diagnosis were similar in all groups. HHS was rated good/excellent by 95 percent of ceramic hips and 97 percent of control hips. Radiographic results demonstrated radiolucency in Femoral Gruen Zone 1 in 3.8 percent (18/474) of ceramic hips and in 8 percent (10/128) of control hips. Unstable acetabular components were reported in none of ceramic hips and in 3.2 percent (5/154) of control hips. Revision was performed in 7 (1.2 percent) ceramic hips, none due to failure of ceramic materials, and in 9 (5.8 percent) control hips. Alumina ceramic materials show promise, but continued evaluation of long-term clinical results is needed.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 50 条
  • [31] Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty
    Young-Kyun Lee
    Jae-Young Lim
    Yong-Chan Ha
    Tae-Young Kim
    Woon-Hwa Jung
    Kyung-Hoi Koo
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1155 - 1162
  • [32] Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty
    Lee, Young-Kyun
    Lim, Jae-Young
    Ha, Yong-Chan
    Kim, Tae-Young
    Jung, Woon-Hwa
    Koo, Kyung-Hoi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (07) : 1155 - 1162
  • [33] Ceramic-on-ceramic total hip replacement
    Riska, EB
    CURRENT ORTHOPAEDICS, 1999, 13 (04): : 320 - 324
  • [34] Influence of Prosthetic Design on Squeaking After Ceramic-on-Ceramic Total Hip Arthroplasty
    Swanson, Todd V.
    Peterson, David J.
    Seethala, Raghavendran
    Bliss, Ryan L.
    Spellmon, Calvin A.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 36 - 42
  • [35] Squeaking After Third-Generation Ceramic-on-Ceramic Total Hip Arthroplasty
    Haq, Rehan-Ul
    Park, Kyung Soon
    Seon, Jong Keun
    Yoon, Taek Rim
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 909 - 915
  • [36] The Survival Analysis in Third-Generation Ceramic-On-Ceramic Total Hip Arthroplasty
    Park, Kyung-Soon
    Seon, Jong-Keun
    Yoon, Taek-Rim
    JOURNAL OF ARTHROPLASTY, 2015, 30 (11): : 1976 - 1980
  • [37] Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
    Blumenfeld, Thomas J.
    Politi, Joel
    Croker, Sean
    O'Dell, Tammy
    Hamilton, William
    ARTHROPLASTY TODAY, 2022, 13 : 130 - 135
  • [38] Adverse local tissue reaction after ceramic-on-ceramic total hip arthroplasty
    Valcarenghi, Jerome
    Poinot, Nicolas
    Verstraeten, Pierre-Bernard
    Chahidi, Esfandiar
    Caufriez, Benoit
    Costenoble, Vincent
    Collard, Xavier
    ACTA ORTHOPAEDICA BELGICA, 2022, 88 (01): : 43 - 46
  • [39] Natural history of noise and squeaking in cementless ceramic-on-ceramic total hip arthroplasty
    Inagaki, Kenta
    Iida, Satoshi
    Miyamoto, Shuichi
    Suzuki, Chiho
    Nakatani, Takushi
    Shinada, Yoshiyuki
    Kawarai, Yuya
    Hagiwara, Shigeo
    Nakamura, Junichi
    Orita, Sumihisa
    Ohtori, Seiji
    JOURNAL OF ORTHOPAEDICS, 2020, 21 : 544 - 549
  • [40] Squeaking sound in total hip arthroplasty using ceramic-on-ceramic bearing surfaces
    Ki, Sung-Chan
    Kim, Byung-Hak
    Ryu, Ji-Hoon
    Yoon, Dae-Hyun
    Chung, Young-Yool
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (01) : 21 - 25