Ceramic-on-ceramic implants in total hip arthroplasty

被引:1
|
作者
Colwell, C
D'Antonio, JA
Capello, WN
Hardwick, ME
机构
[1] Scripps Clin Ctr Orthopaed Res & Educ, La Jolla, CA 92107 USA
[2] Scripps Clin Ctr Orthopaed Res & Educ, Township, PA 15108 USA
[3] Scripps Clin Ctr Orthopaed Res & Educ, Indianapolis, IN 46202 USA
来源
BIOCERAMICS 17 | 2005年 / 284-286卷
关键词
alumina ceramic; total hip arthroplasty;
D O I
10.4028/www.scientific.net/KEM.284-286.1003
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Alumina ceramic is an excellent material for biologic implantation. Decreased particulate wear debris should increase implant longevity. The purpose of this study is to examine clinical and radiological results of ceramic-on-ceramic hip implants compared to cobalt chrome on polyethylene. Four cementless systems were compared, three alumina-on-alumina bearing systems: System I, porous coated cup; System II, hydroxyapatite-coated cup; Trident system, hydroxyapatite-coated cup with metal sleeve backing on ceramic cup liner; and System III (control), porous-coated cup with polyethylene and cobalt chromium bearing system. Patients were randomized to receive System I, II, or III. Trident patients were not randomized. Examinations are performed at 6 months, 1 year and yearly thereafter including x-rays, clinical exam and Harris Hip Score (HHS). Minimum 24-month followup was performed in 562 ceramic hips and 154 control hips. Age, height, weight, gender and diagnosis were similar in all groups. HHS was rated good/excellent by 95 percent of ceramic hips and 97 percent of control hips. Radiographic results demonstrated radiolucency in Femoral Gruen Zone 1 in 3.8 percent (18/474) of ceramic hips and in 8 percent (10/128) of control hips. Unstable acetabular components were reported in none of ceramic hips and in 3.2 percent (5/154) of control hips. Revision was performed in 7 (1.2 percent) ceramic hips, none due to failure of ceramic materials, and in 9 (5.8 percent) control hips. Alumina ceramic materials show promise, but continued evaluation of long-term clinical results is needed.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 50 条
  • [21] Component positioning and ceramic damage in cementless ceramic-on-ceramic total hip arthroplasty
    Castagnini, Francesco
    Valente, Giordano
    Crimi, Gianluigi
    Taddei, Fulvia
    Bordini, Barbara
    Stea, Susanna
    Toni, Aldo
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (04) : 643 - 651
  • [22] Fracture of a ceramic femoral head after ceramic-on-ceramic total hip arthroplasty
    Malillos Toran, Manuel
    Cuenca, Jorge
    Antonio Martinez, Angel
    Herrera, Antonio
    Vicente Thomas, Javier
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1072 - 1073
  • [23] Use of ceramic-on-ceramic bearing in total hip arthroplasty for posttraumatic arthritis of the hip
    Lee, Young-Kyun
    Kim, Ki-Choul
    Kim, Jin-Woo
    Ha, Joo Hyung
    Yoon, Byung-Ho
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [24] Quarter Century Outcomes of Alumina Ceramic-on-Ceramic Total Hip Arthroplasty
    Kim, Hong Seok
    Yoo, Jeong Joon
    JOURNAL OF ARTHROPLASTY, 2025, 40 (04): : 992 - 998
  • [25] Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty
    Baruffaldi, Fabio
    Mecca, Rosaria
    Stea, Susanna
    Beraudi, Alina
    Bordini, Barbara
    Amabile, Marilina
    Sudanese, Alessandra
    Toni, Aldo
    HIP INTERNATIONAL, 2020, 30 (04) : 438 - 445
  • [26] Ceramic-on-Ceramic Total Hip Arthroplasty: I Can Hear You
    Shang, Zhida
    Tanzer, Michael
    Al Badi, Hamid
    Hart, Adam
    Miller, Jo
    ARTHROPLASTY TODAY, 2023, 23
  • [27] Ceramic-on-ceramic total hip arthroplasty in patients with osteonecrosis of the femoral head
    Jung, Jae Ho
    Lee, Tong Joo
    Kim, Su Yeon
    Jung, Sae Rom
    Moon, Kyoung Ho
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (05): : 432 - 436
  • [28] Fracture of a 36-mm ceramic-on-ceramic total hip arthroplasty
    Ho, Ki Wai Kevin
    Chakravertty, Rajesh
    van Vliet, Aaron
    Mahomed, Nizar N.
    CURRENT ORTHOPAEDIC PRACTICE, 2012, 23 (03): : 258 - 261
  • [29] Ceramic-on-Ceramic Versus Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
    Hu, Dongcai
    Yang, Xiao
    Tan, Yang
    Alaidaros, Mohammed
    Chen, Liaobin
    ORTHOPEDICS, 2015, 38 (04) : E331 - E338
  • [30] Squeaking in Large Diameter Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty
    Tai, Stephen M.
    Munir, Selin
    Walter, William L.
    Pearce, Simon J.
    Walter, William K.
    Zicat, Bernard A.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (02): : 282 - 285