The inspection of prestressed concrete structures to the integrity of the tendons

被引:2
|
作者
Hillemeier, Bernd [1 ]
Walther, Andrei [2 ]
机构
[1] Bauwesen Prof Hillemeier & Knapp GmbH, D-14163 Berlin, Germany
[2] BauConsulting Com, D-14770 Brandenburg, Germany
关键词
D O I
10.1002/bate.201101520
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The inspection of prestressed concrete structures to the integrity of the tendons. Bridges are exposed to an ever-increasing traffic load. The age structure, the stress situation and the condition of the bridges are different. More than 20000 bridges in Germany are made of prestressed concrete, whose stability depends essentially on the integrity of the tension reinforcement. Corrosion damages to the tension reinforcement are not visible from the surface. At the Technical University of Berlin, a mobile magnetic measurement system has been developed specifically for bridges. It analyzes the state of the tension wires. This system areas not require any removal of the bridge pavement. In the past ten years 14 prestressed concrete bridges have been studied, five of them in the USA/Canada. The process was evaluated at Lehigh University in Bethlehem (USA), as part of a worldwide comparative study in 2009 and 2010.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [41] Flexural Response of Continuous Concrete Beams Prestressed with External Tendons
    Lou, Tiejiong
    Lopes, Sergio M. R.
    Lopes, Adelino V.
    JOURNAL OF BRIDGE ENGINEERING, 2013, 18 (06) : 525 - 537
  • [42] STRUCTURAL SAFETY INDICES FOR CONCRETE BEAMS PRESTRESSED WITH FRP TENDONS
    Xue, Wei-Chen
    Zheng, Ren-Guang
    Zhang, Shu-Lu
    Yu, Tian-Qi
    Wang, Xiao-Hui
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 799 - 804
  • [43] Shear Behavior of Externally Prestressed Concrete Beams with Draped Tendons
    Qi, Jia-Nan
    Wang, Jing-Quan
    Ma, Zhongguo John
    Tong, Teng
    ACI STRUCTURAL JOURNAL, 2016, 113 (04) : 677 - 688
  • [44] Ultimate stress increase in unbonded tendons in prestressed concrete beams
    Zheng, Wen-zhong
    Wang, Xiao-dong
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2010, 11 (12): : 998 - 1014
  • [45] Evaluation of Flexural Performance for Prestressed Concrete Beams with FRP Tendons
    Cai, Jiangyong
    Tu, Zhifeng
    Gong, Sumin
    Zhuang, Li
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3128 - 3133
  • [46] ULTIMATE STRESS OF UNBONDED TENDONS IN PARTIALLY PRESTRESSED CONCRETE BEAMS
    TAO, XK
    DU, GC
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1985, 30 (06): : 72 - 91
  • [47] Inference of bond slip in prestressed tendons in concrete bridge girders
    Ho, Siu Chun M.
    Ren, Liang
    Labib, Emad
    Kapadia, Aadit
    Mo, Yi-Lung
    Li, Hongnan
    Song, Gangbing
    STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (02): : 289 - 300
  • [48] Effect of bond on flexure of concrete beams prestressed with FRP tendons
    Lou, Tiejiong
    Liu, Muyu
    Lopes, Sergio M. R.
    Lopes, Adelino V.
    COMPOSITE STRUCTURES, 2017, 173 : 168 - 176
  • [49] Fire Resistance of a Concrete Box Beam Prestressed by External Tendons
    Tattoni, S.
    Gasperi, A.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 173 - +
  • [50] Research on strength and durability of GFRP rods for prestressed concrete tendons
    Sugiyama, M
    Uomoto, T
    FIBRE-REINFORCEMENT POLYMER: REINFORCEMENT FOR CONCRETE STRUCTURES, VOLS 1 AND 2, PROCEEDINGS, 2003, : 727 - 736