The inspection of prestressed concrete structures to the integrity of the tendons

被引:2
|
作者
Hillemeier, Bernd [1 ]
Walther, Andrei [2 ]
机构
[1] Bauwesen Prof Hillemeier & Knapp GmbH, D-14163 Berlin, Germany
[2] BauConsulting Com, D-14770 Brandenburg, Germany
关键词
D O I
10.1002/bate.201101520
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The inspection of prestressed concrete structures to the integrity of the tendons. Bridges are exposed to an ever-increasing traffic load. The age structure, the stress situation and the condition of the bridges are different. More than 20000 bridges in Germany are made of prestressed concrete, whose stability depends essentially on the integrity of the tension reinforcement. Corrosion damages to the tension reinforcement are not visible from the surface. At the Technical University of Berlin, a mobile magnetic measurement system has been developed specifically for bridges. It analyzes the state of the tension wires. This system areas not require any removal of the bridge pavement. In the past ten years 14 prestressed concrete bridges have been studied, five of them in the USA/Canada. The process was evaluated at Lehigh University in Bethlehem (USA), as part of a worldwide comparative study in 2009 and 2010.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条