Importance of measuring pharmacologically active metabolites of edoxaban: development and validation of an ultra-high-performance liquid chromatography coupled with a tandem mass spectrometry method

被引:6
|
作者
Siriez, Romain [1 ]
Alpan, Lutfiye [1 ]
Elasaad, Kossay [1 ]
Devel, Philippe [1 ]
Laloy, Julie [2 ]
Dogne, Jean-Michel [1 ]
Douxfils, Jonathan [1 ,3 ]
机构
[1] Univ Namur, NTHC, Namur Res Inst Life Sci NARILIS, Dept Pharm, B-5000 Namur, Belgium
[2] Univ Namur, NNC, Namur Res Inst Life Sci NARILIS, Dept Pharm, Namur, Belgium
[3] Qualiblood Sa, Namur, Belgium
关键词
Edoxaban; Edoxaban-M4; Ultra-high-performance liquid chromatography; tandem mass spectrometry; Metabolite; Direct oral anticoagulant; DIRECT ORAL ANTICOAGULANTS; ASSAYS LABORATORY RECOMMENDATIONS; FACTOR-XA INHIBITOR; COAGULATION ASSAYS; HUMAN PLASMA; IMPACT; RIVAROXABAN; DABIGATRAN; ROUTINE; APIXABAN;
D O I
10.1007/s11239-019-02030-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although DOACs do not require regular measurements of their blood concentrations, clinical situations may require an assessment of their concentration. Among the factor Xa inhibitors, edoxaban is the only compound for which some metabolites (e.g. edoxaban-M4) are reported to be pharmacologically active. Therefore, their contribution could interfere with assays used for the estimation of edoxaban concentration. In addition, drug interactions may alter the metabolite/parent compound ratio making the sole estimation of edoxaban concentration, a poor assessment of the overall anticoagulation. To develop a validated UHPLC-MS/MS method to quantify simultaneously edoxaban and its more relevant M4-metabolite in human plasma. Electrospray ionization and chromatographic separation were optimized for the simultaneous dosage of edoxaban and edoxaban-M4. The method was validated according to regulatory guidelines for bioanalytical method validation. The total run time was 6 min. The method was validated for calibration curves, precision, accuracy, carry-over, selectivity, matrix effect and short-time stability. This method permits quantification of edoxaban and edoxaban-M4 providing complementary information about the inhibitory effect of this active metabolite in chronometric or chromogenic assays. Although patients treated with edoxaban exhibits usually low concentrations of active metabolites, the measurement of edoxaban-M4 is interesting; especially in case of drug interactions. Indeed, concomitant prescriptions of edoxaban and carbamazepine or rifampicin is frequent and may lead to disturbance of the estimations of edoxaban concentration by chromogenic anti-Xa assays. Therefore, patients are at risk of having inadequate control of anticoagulation supporting the need of measuring the most representative edoxaban metabolite concomitantly to the parent compound.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [1] Importance of measuring pharmacologically active metabolites of edoxaban: development and validation of an ultra-high-performance liquid chromatography coupled with a tandem mass spectrometry method
    Romain Siriez
    Lütfiye Alpan
    Kossay Elasaad
    Philippe Devel
    Julie Laloy
    Jean-Michel Dogné
    Jonathan Douxfils
    Journal of Thrombosis and Thrombolysis, 2020, 49 : 395 - 403
  • [2] Method Development for Aminopyralid Residues Determination by Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry in Straw
    Kurhan, Sebnem
    Hankova, Katerina
    Kloucek, Pavel
    Koudela, Martin
    SEPARATIONS, 2024, 11 (01)
  • [3] Development and validation of a fast ultra-high-performance liquid chromatography tandem mass spectrometry method for determining carbonic anhydrase inhibitors and their metabolites in urine and hair
    Lo Faro, Alfredo Fabrizio
    Tini, Anastasio
    Gottardi, Massimo
    Pirani, Filippo
    Sirignano, Ascanio
    Giorgetti, Raffaele
    Busardo, Francesco Paolo
    DRUG TESTING AND ANALYSIS, 2021, 13 (08) : 1552 - 1560
  • [4] Development, Validation, and Clinical Application of an Ultra-High-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for the Determination of 10 Antituberculosis Drugs in Human Serum
    Fan, Xudong
    Guo, Suhang
    Zhang, Ruoying
    Cai, Qingshan
    Lang, Yazhen
    Huang, Jinpeng
    Chen, Yuanyuan
    Zhang, Ying
    Xu, Yingying
    Chen, Meng
    Yang, Gaoyi
    Cai, Xinjun
    THERAPEUTIC DRUG MONITORING, 2024, 46 (04) : 477 - 484
  • [5] Detection of catecholamine metabolites in urine based on ultra-high-performance liquid chromatography-tandem mass spectrometry
    Li, Hui
    Zhang, Guolei
    Wang, Wei
    Jiao, Li-Li
    Chen, Chang-Bao
    Huo, Jing-Rui
    Wu, Wei
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (03)
  • [6] Development and validation of a simultaneous quantitative analytical method for two Alternaria toxins and their metabolites in plasma and urine using ultra-high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Dan
    Liu, Bolin
    Xiao, Tingting
    Wang, Yan
    Zhao, Ziwei
    Xie, Ji'an
    Li, Weidong
    Li, Rui
    Cui, Jie
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (12)
  • [7] Development of a liquid-chromatography tandem mass spectrometry and ultra-high-performance liquid chromatography high-resolution mass spectrometry method for the quantitative determination of zearalenone and its major metabolites in chicken and pig plasma
    De Baere, S.
    Osselaere, A.
    Devreese, M.
    Vanhaecke, L.
    De Backer, P.
    Croubels, S.
    ANALYTICA CHIMICA ACTA, 2012, 756 : 37 - 48
  • [8] Development and validation of a green analytical method for determining fourteen bisphenols in bee pollen by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Ares, Ana M.
    Alcaide, Lucia
    Bernal, Jose
    Valverde, Silvia
    FOOD RESEARCH INTERNATIONAL, 2024, 195
  • [9] High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma
    Agrawal, Nikhil
    Mittal, Amit
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2023, 21 (03) : 110 - 125
  • [10] Development of a validated ultra-high-performance liquid chromatography tandem mass spectrometry method for determination of acid diterpenes in Copaifera oleoresins
    Mangabeira da Silva, Jonas Joaquim
    Crevelin, Eduardo Jose
    Carneiro, Luiza Junqueira
    Rogez, Herve
    Sola Veneziani, Rodrigo Cassio
    Ambrosio, Sergio Ricardo
    Beraldo Moraes, Luiz Alberto
    Bastos, Jairo Kenupp
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 81 - 90