Development and validation of a simultaneous quantitative analytical method for two Alternaria toxins and their metabolites in plasma and urine using ultra-high-performance liquid chromatography-tandem mass spectrometry

被引:4
|
作者
Zhang, Dan [2 ]
Liu, Bolin [1 ,2 ]
Xiao, Tingting [1 ]
Wang, Yan [1 ]
Zhao, Ziwei [1 ]
Xie, Ji'an [1 ]
Li, Weidong [1 ,2 ]
Li, Rui [1 ]
Cui, Jie [1 ]
机构
[1] Anhui Prov CDCP, Phys & Chem Lab, Hefei 230601, Peoples R China
[2] Anhui Med Univ, Sch Publ Hlth, Dept Inspection & Quarantine, Hefei, Peoples R China
关键词
Alternaria; mycotoxins; plasma; UHPLC-MS/MS; urine; MYCOTOXIN TENUAZONIC ACID;
D O I
10.1002/jssc.202400223
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Much more attention has been paid to the contamination of Alternaria toxins because of food contamination and the threat to human health. In this study, an ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed for the simultaneous detection of the prototypical alternariol, alternariol monomethylether, and the metabolites 4-oxhydryl alternariol, and alternariol monomethylether 3-sulfate ammonium salt of Alternaria toxins. The positive samples were used as matrix samples to optimize the different experimental conditions. 0.01% formic acid solution and acetonitrile were used as the mobile phase, and analytes were scanned in negative electron spray ionization under multiple reaction monitoring, and quantitative determination by isotope internal standard method. Application of this method to samples of human plasma and urine showed the detection of the above analytes. The results showed that the recoveries were from 80.40% to 116.4%, intra-day accuracy was between 0.6% and 8.0%, and inter-day accuracy was between 1.1% and 12.1%. The limit of detection of the four analytes ranged from 0.02 to 0.6 mu g/L in urine, and 0.02 to 0.5 mu g/L in plasma, respectively. Thus, the developed method was rapid and accurate for the simultaneous detection of analytes and provided a theoretical basis for the risk assessment of Alternaria toxins for human exposure.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development of simultaneous quantitative analytical method for metabolites of hexosamine biosynthesis pathway in lung cancer cells using ultra-high-performance liquid chromatography-tandem mass spectrometry
    Seo, Yerim
    Chung, Eun Kyoung
    Jung, Byung Hwa
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (08)
  • [2] Detection of catecholamine metabolites in urine based on ultra-high-performance liquid chromatography-tandem mass spectrometry
    Li, Hui
    Zhang, Guolei
    Wang, Wei
    Jiao, Li-Li
    Chen, Chang-Bao
    Huo, Jing-Rui
    Wu, Wei
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (03)
  • [3] Simultaneous determination of androgens and prostaglandins in human urine using ultra-high-performance liquid chromatography-tandem mass spectrometry
    Im, Eunju
    Lew, Bark Lynn
    Lee, Mi Yeon
    Lee, Jeongae
    Paeng, Ki Jung
    Chung, Bong Chul
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1109 : 45 - 53
  • [4] Biomonitoring method for bisphenol A in human urine by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Anderson, David J.
    Brozek, Eric M.
    Cox, Kyley J.
    Porucznik, Christina A.
    Wilkins, Diana G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 953 : 53 - 61
  • [5] Simultaneous Detection of Seven Alternaria Toxins in Mixed Fruit Puree by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Modified QuEChERS
    Xing, Jiali
    Zhang, Zigeng
    Zheng, Ruihang
    Xu, Xiaorong
    Mao, Lingyan
    Lu, Jingping
    Shen, Jian
    Dai, Xianjun
    Yang, Zhenfeng
    TOXINS, 2021, 13 (11)
  • [6] Validation of the Quantitative Determination of Tetrahydrocannabinol and Its Two Major Metabolites in Plasma by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry According to the Total Error Approach
    Dubois, N.
    Paccou, A. P.
    De Backer, B. G.
    Charlier, C. J.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (01) : 25 - 29
  • [7] Determination of Tranquilizers in Swine Urine by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wang, Yingyu
    Li, Xiaowei
    Ke, Yuebin
    Wang, Chengfei
    Zhang, Yuan
    Ye, Dongyang
    Hu, Xue
    Zhou, Lan
    Xia, Xi
    MOLECULES, 2018, 23 (12):
  • [8] Development and validation of a hydrophilic interaction ultra-high-performance liquid chromatography-tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine
    Wen, Yongqing
    Yuan, Xuemei
    Qin, Feng
    Zhao, Longshan
    Xiong, Zhili
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (01)
  • [9] Development and validation of a green analytical method for determining fourteen bisphenols in bee pollen by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Ares, Ana M.
    Alcaide, Lucia
    Bernal, Jose
    Valverde, Silvia
    FOOD RESEARCH INTERNATIONAL, 2024, 195
  • [10] Quantitative analysis of tryptophan and its metabolites in urine by ultra performance liquid chromatography-tandem mass spectrometry
    Li Hui
    Cui Lanchong
    Zhang Guolei
    Zhang Mengmeng
    Jiao Lili
    Wu Wei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (05) : 518 - 525