Development and validation of a simultaneous quantitative analytical method for two Alternaria toxins and their metabolites in plasma and urine using ultra-high-performance liquid chromatography-tandem mass spectrometry

被引:4
|
作者
Zhang, Dan [2 ]
Liu, Bolin [1 ,2 ]
Xiao, Tingting [1 ]
Wang, Yan [1 ]
Zhao, Ziwei [1 ]
Xie, Ji'an [1 ]
Li, Weidong [1 ,2 ]
Li, Rui [1 ]
Cui, Jie [1 ]
机构
[1] Anhui Prov CDCP, Phys & Chem Lab, Hefei 230601, Peoples R China
[2] Anhui Med Univ, Sch Publ Hlth, Dept Inspection & Quarantine, Hefei, Peoples R China
关键词
Alternaria; mycotoxins; plasma; UHPLC-MS/MS; urine; MYCOTOXIN TENUAZONIC ACID;
D O I
10.1002/jssc.202400223
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Much more attention has been paid to the contamination of Alternaria toxins because of food contamination and the threat to human health. In this study, an ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed for the simultaneous detection of the prototypical alternariol, alternariol monomethylether, and the metabolites 4-oxhydryl alternariol, and alternariol monomethylether 3-sulfate ammonium salt of Alternaria toxins. The positive samples were used as matrix samples to optimize the different experimental conditions. 0.01% formic acid solution and acetonitrile were used as the mobile phase, and analytes were scanned in negative electron spray ionization under multiple reaction monitoring, and quantitative determination by isotope internal standard method. Application of this method to samples of human plasma and urine showed the detection of the above analytes. The results showed that the recoveries were from 80.40% to 116.4%, intra-day accuracy was between 0.6% and 8.0%, and inter-day accuracy was between 1.1% and 12.1%. The limit of detection of the four analytes ranged from 0.02 to 0.6 mu g/L in urine, and 0.02 to 0.5 mu g/L in plasma, respectively. Thus, the developed method was rapid and accurate for the simultaneous detection of analytes and provided a theoretical basis for the risk assessment of Alternaria toxins for human exposure.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Detection of seven Alternaria toxins in edible and medicinal herbs using ultra-high performance liquid chromatography-tandem mass spectrometry
    Zhao, Xiangsheng
    Liu, Dan
    Yang, Xinquan
    Zhang, Lei
    Yang, Meihua
    FOOD CHEMISTRY-X, 2022, 13
  • [32] Determination of five Alternaria toxins in wolfberry using modified QuEChERS and ultra-high performance liquid chromatography-tandem mass spectrometry
    Xing, Lijie
    Zou, Liangjun
    Luo, Ruifeng
    Wang, Yuan
    FOOD CHEMISTRY, 2020, 311
  • [33] Development of a liquid-chromatography tandem mass spectrometry and ultra-high-performance liquid chromatography high-resolution mass spectrometry method for the quantitative determination of zearalenone and its major metabolites in chicken and pig plasma
    De Baere, S.
    Osselaere, A.
    Devreese, M.
    Vanhaecke, L.
    De Backer, P.
    Croubels, S.
    ANALYTICA CHIMICA ACTA, 2012, 756 : 37 - 48
  • [34] Development and validation of a fast quantitative method for plasma dimethylarginines analysis using liquid chromatography-tandem mass spectrometry
    D'Apolito, Oceania
    Paglia, Giuseppe
    Tricarico, Filomena
    Garofalo, Daniela
    Pilotti, Alessandra
    Lamacchia, Olga
    Cignarelli, Mauro
    Corso, Gaetano
    CLINICAL BIOCHEMISTRY, 2008, 41 (16-17) : 1391 - 1395
  • [35] Simultaneous Determination of Ticagrelor and Its Metabolites in Human Plasma and Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    Zhong, Wanping
    Wang, Xipei
    Tang, Lan
    Mai, Liping
    Chen, Xiao-Ping
    He, Guodong
    Zheng, Zhijie
    Zhong, Shilong
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (06) : 445 - 453
  • [36] Importance of measuring pharmacologically active metabolites of edoxaban: development and validation of an ultra-high-performance liquid chromatography coupled with a tandem mass spectrometry method
    Siriez, Romain
    Alpan, Lutfiye
    Elasaad, Kossay
    Devel, Philippe
    Laloy, Julie
    Dogne, Jean-Michel
    Douxfils, Jonathan
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2020, 49 (03) : 395 - 403
  • [37] Importance of measuring pharmacologically active metabolites of edoxaban: development and validation of an ultra-high-performance liquid chromatography coupled with a tandem mass spectrometry method
    Romain Siriez
    Lütfiye Alpan
    Kossay Elasaad
    Philippe Devel
    Julie Laloy
    Jean-Michel Dogné
    Jonathan Douxfils
    Journal of Thrombosis and Thrombolysis, 2020, 49 : 395 - 403
  • [38] Simultaneous determination of azelnidipine and two metabolites in human plasma using liquid chromatography-tandem mass spectrometry
    Kawabata, Kiyoshi
    Urasaki, Yoko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 45 - 52
  • [39] Validation of a rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method for quantification of chlorogenic acids in roasted coffee
    Colomban, Silvia
    Guercia, Elena
    Navarini, Luciano
    JOURNAL OF MASS SPECTROMETRY, 2020, 55 (11):
  • [40] Quantitative high-performance liquid chromatography-tandem mass spectrometry method for the analysis of free desmosines in plasma and urine
    Miliotis, Tasso
    Lindberg, Claes
    Semb, Kristina Forsman
    van Geest, Marleen
    Kjellstrom, Sven
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1308 : 73 - 78