Development, Validation, and Clinical Application of an Ultra-High-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for the Determination of 10 Antituberculosis Drugs in Human Serum

被引:0
|
作者
Fan, Xudong [1 ]
Guo, Suhang [1 ]
Zhang, Ruoying [1 ]
Cai, Qingshan [1 ]
Lang, Yazhen [1 ]
Huang, Jinpeng [1 ]
Chen, Yuanyuan [1 ]
Zhang, Ying [1 ]
Xu, Yingying [1 ]
Chen, Meng [2 ]
Yang, Gaoyi [1 ]
Cai, Xinjun [1 ]
机构
[1] Hangzhou Red Cross Hosp, Dept Pharm, 208 Huancheng East Rd, Hangzhou 310003, Zhejiang, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 2, Sch Med, Dept Pharm, Hangzhou, Peoples R China
关键词
antituberculosis drugs; UHPLC-MS/MS; therapeutic drug monitoring; methodology validation; clinical application; TUBERCULOSIS; PLASMA;
D O I
10.1097/FTD.0000000000001170
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Linezolid, moxifloxacin, rifapentine, rifabutin, cycloserine, clofazimine, bedaquiline, levofloxacin, prothionamide, and ethionamide are commonly used second-line antituberculosis (anti-TB) drugs. To support therapeutic drug monitoring in regular clinical practice, the authors sought to develop a method based on ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) that would allow for the simultaneous quantification of multiple second-line anti-TB drugs in human serum. Methods: Analytes were extracted from human serum by protein precipitation. UHPLC-MS/MS was performed using a gradient at a flow rate of 0.3 mL/min, and each sample was taken for 7.5 minutes. The mass spectrometry scanning mode used was electrospray ionization with multiple reaction monitoring in the positive mode. Results: Validation showed that endogenous substances in the sample did not interfere with the assay, and the relationship between X and Y was highly linear, with a coefficient of determination (R-2) >0.9954 for each curve. The accuracy (85.0%-114.7%) and precision (intraday: 0.27%-9.32%; interday: 0.20%-7.66%) were less than 15.0%, and the internal standard-normalized matrix effects were consistent (coefficient of variation <= 4.40%). The analytes were stable in the final extract and human serum under various storage conditions (recovery: 87.0%-115.0%). The clinical applicability of the method was demonstrated by quantitative determination of analytes in serum samples obtained from patients with TB. Reproducibility of the drug concentrations measured in clinical samples was confirmed by incurred sample reanalysis. Conclusions: A simple and reliable analytical method was developed and validated for the simultaneous determination of 10 anti-TB drugs in human serum using UHPLC-MS/MS. Quantitation of anti-TB drugs in clinical samples confirmed that the assay is suitable for therapeutic drug monitoring in regular clinical practice.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 50 条
  • [1] Method Development for Aminopyralid Residues Determination by Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry in Straw
    Kurhan, Sebnem
    Hankova, Katerina
    Kloucek, Pavel
    Koudela, Martin
    SEPARATIONS, 2024, 11 (01)
  • [2] Development and validation of an ultra-performance liquid chromatography method coupled with tandem mass spectrometry for determination of alizapride in human plasma
    Zaazaa, H. E.
    Elzanfaly, E. S.
    Soudi, A. T.
    Salem, M. Y.
    RSC ADVANCES, 2015, 5 (93): : 76377 - 76382
  • [3] Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for determination of 10 cephalosporins and desacetylcefapirin in milk
    Hou, Xiao-Lin
    Wu, Yin-Liang
    Lv, Yan
    Xu, Xiu-Qin
    Zhao, Jian
    Yang, Ting
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 6 - 11
  • [4] Importance of measuring pharmacologically active metabolites of edoxaban: development and validation of an ultra-high-performance liquid chromatography coupled with a tandem mass spectrometry method
    Romain Siriez
    Lütfiye Alpan
    Kossay Elasaad
    Philippe Devel
    Julie Laloy
    Jean-Michel Dogné
    Jonathan Douxfils
    Journal of Thrombosis and Thrombolysis, 2020, 49 : 395 - 403
  • [5] Importance of measuring pharmacologically active metabolites of edoxaban: development and validation of an ultra-high-performance liquid chromatography coupled with a tandem mass spectrometry method
    Siriez, Romain
    Alpan, Lutfiye
    Elasaad, Kossay
    Devel, Philippe
    Laloy, Julie
    Dogne, Jean-Michel
    Douxfils, Jonathan
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2020, 49 (03) : 395 - 403
  • [6] Development of a validated ultra-high-performance liquid chromatography tandem mass spectrometry method for determination of acid diterpenes in Copaifera oleoresins
    Mangabeira da Silva, Jonas Joaquim
    Crevelin, Eduardo Jose
    Carneiro, Luiza Junqueira
    Rogez, Herve
    Sola Veneziani, Rodrigo Cassio
    Ambrosio, Sergio Ricardo
    Beraldo Moraes, Luiz Alberto
    Bastos, Jairo Kenupp
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 81 - 90
  • [7] Development and validation of a method using ultra performance liquid chromatography coupled to tandem mass spectrometry for determination of zoledronic acid concentration in human bone
    Lo Faro, Alfredo Fabrizio
    Giorgetti, Raffaele
    Busardo, Francesco Paolo
    Lodi, Giovanni
    Martini, Valeria
    Pispero, Alberto
    Iriti, Marcello
    Varoni, Elena Maria
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 162 : 286 - 290
  • [8] Multiclass Method for the Determination of Anthelmintic and Antiprotozoal Drugs in Livestock Products by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Park, Hyunjin
    Kim, Eunjung
    Lee, Tae Ho
    Park, Sihyun
    Choi, Jang-Duck
    Moon, Guiim
    FOOD SCIENCE OF ANIMAL RESOURCES, 2023, 43 (05) : 914 - 937
  • [9] Determination of Phenolic Compounds in Artichoke, Garlic and Spinach by Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Isabel Alarcon-Flores, Maria
    Romero-Gonzalez, Roberto
    Martinez Vidal, Jose Luis
    Garrido Frenich, Antonia
    FOOD ANALYTICAL METHODS, 2014, 7 (10) : 2095 - 2106
  • [10] Determination of Phenolic Compounds in Artichoke, Garlic and Spinach by Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    María Isabel Alarcón-Flores
    Roberto Romero-González
    José Luis Martínez Vidal
    Antonia Garrido Frenich
    Food Analytical Methods, 2014, 7 : 2095 - 2106