Development, Validation, and Clinical Application of an Ultra-High-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for the Determination of 10 Antituberculosis Drugs in Human Serum

被引:0
|
作者
Fan, Xudong [1 ]
Guo, Suhang [1 ]
Zhang, Ruoying [1 ]
Cai, Qingshan [1 ]
Lang, Yazhen [1 ]
Huang, Jinpeng [1 ]
Chen, Yuanyuan [1 ]
Zhang, Ying [1 ]
Xu, Yingying [1 ]
Chen, Meng [2 ]
Yang, Gaoyi [1 ]
Cai, Xinjun [1 ]
机构
[1] Hangzhou Red Cross Hosp, Dept Pharm, 208 Huancheng East Rd, Hangzhou 310003, Zhejiang, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 2, Sch Med, Dept Pharm, Hangzhou, Peoples R China
关键词
antituberculosis drugs; UHPLC-MS/MS; therapeutic drug monitoring; methodology validation; clinical application; TUBERCULOSIS; PLASMA;
D O I
10.1097/FTD.0000000000001170
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Linezolid, moxifloxacin, rifapentine, rifabutin, cycloserine, clofazimine, bedaquiline, levofloxacin, prothionamide, and ethionamide are commonly used second-line antituberculosis (anti-TB) drugs. To support therapeutic drug monitoring in regular clinical practice, the authors sought to develop a method based on ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) that would allow for the simultaneous quantification of multiple second-line anti-TB drugs in human serum. Methods: Analytes were extracted from human serum by protein precipitation. UHPLC-MS/MS was performed using a gradient at a flow rate of 0.3 mL/min, and each sample was taken for 7.5 minutes. The mass spectrometry scanning mode used was electrospray ionization with multiple reaction monitoring in the positive mode. Results: Validation showed that endogenous substances in the sample did not interfere with the assay, and the relationship between X and Y was highly linear, with a coefficient of determination (R-2) >0.9954 for each curve. The accuracy (85.0%-114.7%) and precision (intraday: 0.27%-9.32%; interday: 0.20%-7.66%) were less than 15.0%, and the internal standard-normalized matrix effects were consistent (coefficient of variation <= 4.40%). The analytes were stable in the final extract and human serum under various storage conditions (recovery: 87.0%-115.0%). The clinical applicability of the method was demonstrated by quantitative determination of analytes in serum samples obtained from patients with TB. Reproducibility of the drug concentrations measured in clinical samples was confirmed by incurred sample reanalysis. Conclusions: A simple and reliable analytical method was developed and validated for the simultaneous determination of 10 anti-TB drugs in human serum using UHPLC-MS/MS. Quantitation of anti-TB drugs in clinical samples confirmed that the assay is suitable for therapeutic drug monitoring in regular clinical practice.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 50 条
  • [41] Validation of a Method for the Determination of Chloramphenicol in Poultry and Swine Liver by Ultra-Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Xia, Xi
    Li, Xiaowei
    Ding, Shuangyang
    Shen, Jianzhong
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (05) : 1666 - 1671
  • [42] Determination of benzophenone and related compounds in plastic packaged baby food by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry
    Medina-Perez, N., I
    Arrizabalaga-Larranaga, A.
    Sero, R.
    Moyano, E.
    ANALYTICAL METHODS, 2020, 12 (03) : 358 - 367
  • [43] Simultaneous determination of triazole fungicides in animal-origin food by ultra-high-performance liquid chromatography coupled with tandem mass spectrometry
    Xing, Lijie
    Liu, Yang
    Li, Wenqi
    Zou, Liangjun
    Wang, Yuan
    Luo, Ruifeng
    FOOD CHEMISTRY-X, 2023, 20
  • [44] Simultaneous Determination of Four Biogenic and Three Volatile Amines in Anchovy by Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Romero-Gonzalez, Roberto
    Isabel Alarcon-Flores, Maria
    Martinez Vidal, Jose Luis
    Garrido Frenich, Antonia
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (21) : 5324 - 5329
  • [45] Rapid determination of benzophenone derivatives in cereals using FaPEx coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry
    Huang, Yu-Fang
    Chien, Jui-Ting
    Chen, Hsin-Chang
    Liu, Xuan-Rui
    Chang, Jui-Pin
    Huang, Jun-Jie
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2021, 29 (02) : 287 - 302
  • [46] Determination of Ecdysterone in Dietary Supplements and Spinach by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Grucza, Krzysztof
    Wicka, Mariola
    Drapala, Aleksandra
    Kwiatkowska, Dorota
    SEPARATIONS, 2022, 9 (01)
  • [47] Evaluation of Ultra-High-Performance Liquid Chromatography (HPLC) Tandem Mass Spectrometry for Determination of Avermectin Residues in Milk
    Bayer, O. V.
    Kaminska, O. V.
    Bondarets, O. V.
    Yaremchuk, O. S.
    Skoromna, O. I.
    Midyk, S. V.
    Shevchenko, L. V.
    Mykhalska, V. M.
    Stupak, O. M.
    Liniichuk, N. V.
    UKRAINIAN JOURNAL OF ECOLOGY, 2019, 9 (04): : 521 - 526
  • [48] Multiresidue determination of veterinary drugs in aquaculture fish samples by ultra high performance liquid chromatography coupled to tandem mass spectrometry
    Pereira Lopes, Renata
    Cazoria Reyes, Rocio
    Romero-Gonzalez, Roberto
    Martinez Vidal, Jose Luis
    Garrido Frenich, Antonia
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 895 : 39 - 47
  • [49] Determination of biocides in different environmental matrices by use of ultra-high-performance liquid chromatography–tandem mass spectrometry
    Zhi-Feng Chen
    Guang-Guo Ying
    Hua-Jie Lai
    Feng Chen
    Hao-Chang Su
    You-Sheng Liu
    Fu-Qiang Peng
    Jian-Liang Zhao
    Analytical and Bioanalytical Chemistry, 2012, 404 : 3175 - 3188
  • [50] Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma
    Lee, Hyun-Soo
    Kang, Il-Mo
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Myung-Jae
    Jeong, Seo-Young
    Cho, Young-Wuk
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01): : 158 - 162