Validation of pre-procedural aortic aneurysm volume calculations to estimate procedural fill volume of endobags in endovascular aortic sealing

被引:4
|
作者
Boersen, Johannes T. [1 ,2 ]
van den Ham, Leo H. [3 ]
Heyligers, Jan M. [4 ]
Vahl, Anco C. [5 ]
Vriens, Patrick W. [4 ]
Reijnen, Michel M. [3 ]
de Vries, Jean-Paul P. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, Nieuwegein, Netherlands
[2] Univ Twente, MIRA Inst Tech Med & Biomed Technol, Enschede, Netherlands
[3] Rijnstate Hosp, Dept Surg, Arnhem, Netherlands
[4] St Elizabeth Hosp, Dept Vasc Surg, Tilburg, Netherlands
[5] Onze Lieve Vrouw Hosp, Dept Vasc Surg, Amsterdam, Netherlands
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2017年 / 58卷 / 05期
关键词
Vascular closure devices; Abdominal aortic aneurysm; Balloon angioplasty; JUXTARENAL ANEURYSM; SOFTWARE; THROMBUS;
D O I
10.23736/S0021-9509.16.08820-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Endovascular aortic sealing (EVAS) with a sac anchoring endoprosthesis excludes abdominal aortic aneurysms based on polymer filling of endobags. Primary objective was to assess the reliability of pre-procedural computed tomography (CT) scans based calculations of required endobag volume in relation to intraoperative volume of the endobags. METHODS: Forty elective EVAS patients were included. Pre-procedural estimations of endobag volume were based on CT segmentations of aortic flow lumen volume, including both automated and manually-adjusted segmentations, performed by two experienced users. Additionally, changes in maximum AAA diameter, thrombus volume and total AAA volume were calculated from pre-and post-procedural CT scans. RESULTS: Automatically determined volumes were comparable to manually-adjusted calculations (75.3 vs. 75.7 mL) and inter-observer agreement regarding pre-EVAS calculations of prefill volume appeared almost perfect with an intra-class correlation coefficient of 0.98 (95% CI: 0.96-0.99). The mean pressure of the endobags was 185 mmHg. Manually-adjusted pre-procedural volume calculations underestimated procedural volume of the endobags (-11.3 +/- 9.9 mL). Differences between pre-EVAS and procedural volume measurements were independent from endobag pressure (r=-0.06, P=0.72), prepocedural thrombus volume (r=-0.303, P=0.057) and changes in total AAA volume (r=0.02, P=0.91). A significant association was determined between differences in pre-EVAS and endobag volume versus changes in thrombus volume pre-and post-procedural (r=0.39, P=0.01). CONCLUSIONS: In this validation study, pre-procedural volume measurements underestimate the actual fill volume of the endobags. It should be advised to perform a prefill of the endobags during the EVAS procedure.
引用
收藏
页码:674 / 679
页数:6
相关论文
共 50 条
  • [1] Towards biomechanics-based pre-procedural planning for thoracic endovascular aortic repair of aortic dissection
    Kan, Xiaoxin
    Ma, Tao
    Jiang, Xiaolang
    Holzapfel, Gerhard A.
    Dong, Zhihui
    Xu, Xiao Yun
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 244
  • [2] Pre-Procedural Evaluation of Circumferential Aortic Strain With Transesophageal Echocardiography: A Validation Study
    Palumbo, Maria Chiara
    Huynh, Samantha
    Devereux, Richard B.
    Kim, Jiwon
    Girardi, Leonard N.
    Gaudino, Mario
    Weinsaft, Jonathan W.
    Rong, Lisa
    CIRCULATION, 2019, 140
  • [3] Impact of low pre-procedural stroke volume index on cumulative mortality of patients undergoing transcatheter aortic valve implantation
    Drakopoulou, M.
    Michelongona, A.
    Toutouzas, K.
    Brili, S.
    Stathogiannis, K.
    Trantalis, G.
    Kaitozis, O.
    Synetos, A.
    Latsios, G.
    Aggeli, C.
    Lazaros, G.
    Papanikolaou, A.
    Peskesis, G.
    Tsiamis, E.
    Tousoulis, D.
    EUROPEAN HEART JOURNAL, 2016, 37 : 210 - 210
  • [4] A guide for pre-procedural imaging for transcatheter aortic valve replacement patients
    Perry, Tjorvi E.
    George, Stephen A.
    Lee, Belinda
    Wahr, Joyce
    Randle, Darrell
    Sigurosson, Garoar
    PERIOPERATIVE MEDICINE, 2020, 9 (01)
  • [5] The impact of the pre-procedural hemodynamic assessment in transcatheter aortic valve replacement
    Bugan, Baris
    Kapadia, Samir R.
    Tuzcu, E. Murat
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2014, 14 (02): : 201 - 202
  • [6] Circadian Variation in Pre-Procedural Rupture of Acute Type A Aortic Dissection
    Lu, Chen
    Hu, Jia
    CIRCULATION, 2022, 146
  • [7] Planning for Success Pre-procedural Evaluation for Transcatheter Aortic Valve Replacement
    Ng, Vivian G.
    Hahn, Rebecca T.
    Nazif, Tamim M.
    CARDIOLOGY CLINICS, 2020, 38 (01) : 103 - +
  • [8] A guide for pre-procedural imaging for transcatheter aortic valve replacement patients
    Tjörvi E. Perry
    Stephen A. George
    Belinda Lee
    Joyce Wahr
    Darrell Randle
    Garðar Sigurðsson
    Perioperative Medicine, 9
  • [9] Pre-procedural risk models for patients undergoing transcatheter aortic valve implantation
    Martin, Glen P.
    Sperrin, Matthew
    Mamas, Mamas A.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S3560 - S3567
  • [10] Procedural Volume and Outcomes for Transcatheter Aortic-Valve Replacement
    Vemulapalli, Sreekanth
    Carroll, John D.
    Mack, Michael J.
    Li, Zhuokai
    Dai, David
    Kosinski, Andrzej S.
    Kumbhani, Dharam J.
    Ruiz, Carlos E.
    Thourani, Vinod H.
    Hanzel, George
    Gleason, Thomas G.
    Herrmann, Howard C.
    Brindis, Ralph G.
    Bavaria, Joseph E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (26): : 2541 - 2550