Validation of pre-procedural aortic aneurysm volume calculations to estimate procedural fill volume of endobags in endovascular aortic sealing

被引:4
|
作者
Boersen, Johannes T. [1 ,2 ]
van den Ham, Leo H. [3 ]
Heyligers, Jan M. [4 ]
Vahl, Anco C. [5 ]
Vriens, Patrick W. [4 ]
Reijnen, Michel M. [3 ]
de Vries, Jean-Paul P. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, Nieuwegein, Netherlands
[2] Univ Twente, MIRA Inst Tech Med & Biomed Technol, Enschede, Netherlands
[3] Rijnstate Hosp, Dept Surg, Arnhem, Netherlands
[4] St Elizabeth Hosp, Dept Vasc Surg, Tilburg, Netherlands
[5] Onze Lieve Vrouw Hosp, Dept Vasc Surg, Amsterdam, Netherlands
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2017年 / 58卷 / 05期
关键词
Vascular closure devices; Abdominal aortic aneurysm; Balloon angioplasty; JUXTARENAL ANEURYSM; SOFTWARE; THROMBUS;
D O I
10.23736/S0021-9509.16.08820-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Endovascular aortic sealing (EVAS) with a sac anchoring endoprosthesis excludes abdominal aortic aneurysms based on polymer filling of endobags. Primary objective was to assess the reliability of pre-procedural computed tomography (CT) scans based calculations of required endobag volume in relation to intraoperative volume of the endobags. METHODS: Forty elective EVAS patients were included. Pre-procedural estimations of endobag volume were based on CT segmentations of aortic flow lumen volume, including both automated and manually-adjusted segmentations, performed by two experienced users. Additionally, changes in maximum AAA diameter, thrombus volume and total AAA volume were calculated from pre-and post-procedural CT scans. RESULTS: Automatically determined volumes were comparable to manually-adjusted calculations (75.3 vs. 75.7 mL) and inter-observer agreement regarding pre-EVAS calculations of prefill volume appeared almost perfect with an intra-class correlation coefficient of 0.98 (95% CI: 0.96-0.99). The mean pressure of the endobags was 185 mmHg. Manually-adjusted pre-procedural volume calculations underestimated procedural volume of the endobags (-11.3 +/- 9.9 mL). Differences between pre-EVAS and procedural volume measurements were independent from endobag pressure (r=-0.06, P=0.72), prepocedural thrombus volume (r=-0.303, P=0.057) and changes in total AAA volume (r=0.02, P=0.91). A significant association was determined between differences in pre-EVAS and endobag volume versus changes in thrombus volume pre-and post-procedural (r=0.39, P=0.01). CONCLUSIONS: In this validation study, pre-procedural volume measurements underestimate the actual fill volume of the endobags. It should be advised to perform a prefill of the endobags during the EVAS procedure.
引用
收藏
页码:674 / 679
页数:6
相关论文
共 50 条
  • [31] Impact of procedural volume on outcome optimization in transaortic transcatheter aortic valve implantation
    Arai, Takahide
    Romano, Mauro
    Lefevre, Thierry
    Hovasse, Thomas
    Bouvier, Erik
    Morice, Marie-Claude
    Farge, Arnaud
    Garot, Philippe
    Chevalier, Bernard
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 292 - 296
  • [32] Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair
    Rai, Divyajeet
    Wisniowski, Brendan
    Bradshaw, Barbara
    Velu, Ramesh
    Tosenovsky, Patrik
    Quigley, Francis
    Walker, Philip J.
    Golledge, Jonathan
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1768 - 1776
  • [33] Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair
    Divyajeet Rai
    Brendan Wisniowski
    Barbara Bradshaw
    Ramesh Velu
    Patrik Tosenovsky
    Francis Quigley
    Philip J. Walker
    Jonathan Golledge
    European Radiology, 2014, 24 : 1768 - 1776
  • [34] Pre-Procedural Hemodynamic Status Improves the Discriminatory Value of the Aortic Regurgitation Index in Patients Undergoing Transcatheter Aortic Valve Replacement
    Sinning, Jan-Malte
    Stundl, Anja
    Pingel, Simon
    Weber, Marcel
    Sedaghat, Alexander
    Hammerstingl, Christoph
    Vasa-Nicotera, Mariuca
    Mellert, Fritz
    Schiller, Wolfgang
    Kovac, Jan
    Welz, Armin
    Grube, Eberhard
    Werner, Nikos
    Nickenig, Georg
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07) : 700 - 711
  • [35] Low pre-procedural trans-aortic gradient predicts adverse clinical outcome after transcatheter aortic valve implantation
    Amabile, Nicolas
    Ramadon, Ramzi
    Ghostine, Said
    Azmoun, Alexandre
    Raoux, Francois
    To, Ngoc-Tram
    Troussier, Xavier
    Haddouche, Yacine
    Nottin, Remi
    Caussin, Christophe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B37 - B37
  • [36] IMPACT OF PRE-PROCEDURAL SIGNIFICANT MITRAL REGURGITATION UPON MORTALITY AFTER TRANSCATHETER AORTIC VALVE INTERVENTION FOR SEVERE AORTIC STENOSIS
    Drakopoulou, Maria I.
    Toutouzas, Konstantinos
    Stathogiannis, Konstantinos
    Michelongona, Archontoula
    Latsios, George
    Synetos, Andreas
    Kaitozis, Odysseas
    Aggeli, Constadina
    Tsiamis, Eleftherios
    Tousoulis, Dimitris
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 237 - 237
  • [37] Impact of Pre-procedural Cerebrovascular Events on Clinical Outcomes After Transcatheter Aortic Valve Implantation in Patients with Severe Aortic Stenosis
    Wiktorowicz, Agata
    Kleczynski, Pawel
    Dziewierz, Artur
    Tokarek, Tomasz
    Sorysz, Danuta
    Bagienski, Maciej
    Rzeszutko, Lukasz
    Dudek, Dariusz
    CURRENT PHARMACEUTICAL DESIGN, 2018, 24 (05) : 641 - 646
  • [38] The effect of pre-procedural significant mitral regurgitation upon mortality after transcatheter aortic valve intervention for severe aortic stenosis
    Michelongona, A.
    Drakopoulou, M.
    Toutouzas, K.
    Brili, S.
    Kaitozis, O.
    Stathogiannis, K.
    Synetos, A.
    Latsios, G.
    Trantalis, G.
    Aggeli, C.
    Lazaros, G.
    Sideris, S.
    Papanikolaou, A.
    Tsiamis, E.
    Tousoulis, D.
    EUROPEAN HEART JOURNAL, 2016, 37 : 748 - 749
  • [39] Endovascular technology, hospital volume, and mortality with abdominal aortic aneurysm surgery
    Dimick, Justin B.
    Upchurch, Gilbert R., Jr.
    JOURNAL OF VASCULAR SURGERY, 2008, 47 (06) : 1150 - 1154
  • [40] Serial CT volume measurements after endovascular aortic aneurysm repair
    Czermak, BV
    Fraedrich, G
    Schocke, MF
    Steingruber, IE
    Waldenberger, P
    Perkmann, R
    Rieger, M
    Jaschke, WR
    JOURNAL OF ENDOVASCULAR THERAPY, 2001, 8 (04) : 380 - 389