Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial

被引:32
|
作者
Huang, Jessie [1 ,2 ]
Katalinic, Paula [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
Hennessy, Michael P. [1 ,3 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Univ New South Wales Sydney, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales Sydney, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
OCULAR HYPERTENSION; REBOUND TONOMETER; RISK-FACTOR; ICARE-ONE; PROGRESSION; 24-HOUR; ACCURACY; TERM; PATTERNS;
D O I
10.1097/OPX.0000000000001172
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE: The aim of this study was to prospectively investigate the utility of rebound self-tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS: Forty patients were recruited following glaucoma-specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS: Twenty-seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self-measured IOP on 118 (29) occasions for 40 (+/- 7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period (r(2) = 0.82, P < .0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (+/- 5.2) to 16.1 (+/- 2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS: Rebound self-tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
  • [42] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924
  • [43] Frequency of asymmetric intraocular pressure fluctuations among patients with and without glaucoma
    Realini, T
    Barber, L
    Burton, D
    OPHTHALMOLOGY, 2002, 109 (07) : 1367 - 1371
  • [44] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Shaoying Tan
    Marco Yu
    Nafees Baig
    Linda Hansapinyo
    Clement C. Tham
    Scientific Reports, 7
  • [45] Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients
    Tan, Shaoying
    Yu, Marco
    Baig, Nafees
    Hansapinyo, Linda
    Tham, Clement C.
    SCIENTIFIC REPORTS, 2017, 7
  • [46] Self-Monitoring of Intraocular Pressure Outside of Normal Office Hours Using Rebound Tonometry: Initial Clinical Experience in Patients With Normal Tension Glaucoma
    Sood, Vaneeta
    Ramanathan, Uthaya S.
    JOURNAL OF GLAUCOMA, 2016, 25 (10) : 807 - 811
  • [47] MEDICAL THERAPY + DIURNAL VARIATIONS OF INTRAOCULAR PRESSURE IN GLAUCOMA
    BARSAM, PC
    VOGEL, HP
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1964, 58 (06) : 1027 - &
  • [48] DIURNAL INTRAOCULAR PRESSURE VARIATION IN A GLAUCOMA SCREENING PROGRAM
    LENNON, RG
    TURNBULL, CD
    ARCHIVES OF OPHTHALMOLOGY, 1968, 80 (06) : 714 - &
  • [49] Long-Term Reproducibility of Diurnal Intraocular Pressure Patterns in Patients with Glaucoma
    Aptel, Florent
    Lesoin, Antoine
    Chiquet, Christophe
    Aryal-Charles, Nishal
    Noel, Christian
    Romanet, Jean-Paul
    OPHTHALMOLOGY, 2014, 121 (10) : 1998 - 2003
  • [50] EFFECT OF PILOCARPINE DROPS ON DIURNAL INTRAOCULAR-PRESSURE VARIATION IN PATIENTS WITH GLAUCOMA
    WORTHEN, DM
    INVESTIGATIVE OPHTHALMOLOGY, 1976, 15 (09): : 784 - 787