Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial

被引:32
|
作者
Huang, Jessie [1 ,2 ]
Katalinic, Paula [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
Hennessy, Michael P. [1 ,3 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Univ New South Wales Sydney, Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales Sydney, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Prince Wales Hosp, Dept Ophthalmol, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
OCULAR HYPERTENSION; REBOUND TONOMETER; RISK-FACTOR; ICARE-ONE; PROGRESSION; 24-HOUR; ACCURACY; TERM; PATTERNS;
D O I
10.1097/OPX.0000000000001172
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE: The aim of this study was to prospectively investigate the utility of rebound self-tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS: Forty patients were recruited following glaucoma-specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS: Twenty-seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self-measured IOP on 118 (29) occasions for 40 (+/- 7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period (r(2) = 0.82, P < .0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (+/- 5.2) to 16.1 (+/- 2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS: Rebound self-tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
  • [1] Clinical Trial: Diurnal IOP Fluctuations in Glaucoma Using Latanoprost and Timolol with Self-Tonometry
    Tong, Janelle
    Huang, Jessie
    Kalloniatis, Michael
    Coroneo, Minas
    Zangerl, Barbara
    OPTOMETRY AND VISION SCIENCE, 2021, 98 (08) : 901 - 913
  • [2] Self-tonometry with a Telemetric Intraocular Pressure Sensor in Patients With Glaucoma
    Koutsonas, A.
    Walter, P.
    Plange, N.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (06) : 743 - 748
  • [3] SELF-TONOMETRY TO MANAGE PATIENTS WITH GLAUCOMA AND APPARENTLY CONTROLLED INTRAOCULAR-PRESSURE
    WILENSKY, JT
    GIESER, DK
    MORI, MT
    LANGENBERG, PW
    ZEIMER, RC
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (08) : 1072 - 1075
  • [4] Monitoring daily intraocular pressure fluctuations with self-tonometry in healthy subjects
    Querat, Laurence
    Chen, Enping
    ACTA OPHTHALMOLOGICA, 2017, 95 (05) : 525 - 529
  • [5] Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
    Lam, DSC
    Leung, DYL
    Chiu, TYH
    Fan, DSP
    Cheung, EYY
    Wong, TY
    Lai, JSM
    Tham, CCY
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) : 3131 - 3136
  • [6] Self-tonometry in glaucoma
    Tarkkanen, Ahti
    Ulfves, Kristian
    Ulfves, Tuulikki
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (11) : 1679 - 1681
  • [7] Self-tonometry in glaucoma
    Ahti Tarkkanen
    Kristian Ulfves
    Tuulikki Ulfves
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1679 - 1681
  • [8] Home- or self-tonometry to the follow-up of intraocular pressure in glaucoma
    Tarkkanen, Ahti
    Puska, Paivi
    Kivela, Tero
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E803 - E804
  • [9] Self-tonometry as a complement in the investigation of glaucoma patients
    Chen, Enping
    Querat, Laurence
    Akerstedt, Christina
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : 788 - 792
  • [10] Home Self-tonometry Trials Compared with Clinic Tonometry in Patients with Glaucoma
    McGlumphy, Elyse J.
    Mihailovic, Aleksandra
    Ramulu, Pradeep Y.
    Johnson, Thomas, V
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (06): : 569 - 580