Validation of Geant4 10.3 simulation of proton interaction for space radiation effects

被引:24
|
作者
Ivanchenko, Vladimir [1 ,2 ]
Dondero, Paolo [3 ]
Fioretti, Valentina [4 ]
Ivantchenko, Anton [5 ]
Lei, Fan [6 ]
Lotti, Simone [7 ]
Mantero, Alfonso [3 ]
Mineo, Teresa [8 ]
机构
[1] CERN, Geneve 23, CH-1211 Geneva, Switzerland
[2] Tomsk State Univ, Leninsky Pr 36, Tomsk 634050, Russia
[3] SWHARD SRL, Via Greto Cornigliano 6R, I-16152 Genoa, Italy
[4] IASF Bologna, INAF, Via P Gobetti 101, I-40129 Bologna, Italy
[5] Geant4 Associate Int Ltd, 9 Royd Terrace, Hebden Bridge HX7 7BT, England
[6] RadMod Res, Camberley, Hants, England
[7] IAPS, INAF, Via Fosso Cavaliere 100, I-00133 Rome, Italy
[8] IASF Palermo, INAF, Via Ugo Malfa 153, I-90146 Palermo, Italy
关键词
Geant4; Monte Carlo; Validation; PRODUCTION CROSS-SECTIONS; ENERGY-LOSS; CASCADE; PHYSICS;
D O I
10.1007/s10686-017-9556-z
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Monte Carlo simulation of space radiation effects induced by protons is important for design of space missions. Geant4 is a well established toolkit for Monte Carlo simulation focused on high energy physics applications. In this work, a set of new validation results versus data for Geant4 electromagnetic and hadronic interaction of protons is presented and discussed. Optimal configuration of Geant4 physics for space applications is proposed.
引用
收藏
页码:437 / 450
页数:14
相关论文
共 50 条
  • [31] PIXE simulation in Geant4
    Mantero, A.
    Ben Abdelouahed, H.
    Champion, C.
    El Bitar, Z.
    Francis, Z.
    Gueye, P.
    Incerti, S.
    Ivanchenko, V.
    Maire, M.
    X-RAY SPECTROMETRY, 2011, 40 (03) : 135 - 140
  • [32] PIXE Simulation With Geant4
    Pia, Maria Grazia
    Weidenspointner, Georg
    Augelli, Mauro
    Quintieri, Lina
    Saracco, Paolo
    Sudhakar, Manju
    Zoglauer, Andreas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (06) : 3614 - 3649
  • [33] The ALICE Geant4 Simulation
    Hrivnacova, I.
    Datskova, O.
    Gheata, A.
    Morsch, A.
    Sicking, E.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2010): EVENT PROCESSING, 2011, 331
  • [34] Geant4 - A new Monte Carlo toolkit for simulating space radiation shielding and effects
    Truscott, P
    Lei, F
    Dyer, C
    Ferguson, C
    Gurriaran, R
    Nieminen, P
    Daly, E
    Apostolakis, J
    Giani, S
    Pia, MG
    Urban, L
    Maire, M
    2000 IEEE RADIATION EFFECTS DATA WORKSHOP - WORKSHOP RECORD, 2000, : 147 - 152
  • [35] Models of biological effects of radiation in the Geant4 Toolkit
    Chauvie, S.
    Francis, Z.
    Guatelli, S.
    Incerti, S.
    Mascialino, B.
    Montarou, G.
    Moretto, P.
    Nieminen, P.
    Pia, M. G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 803 - 805
  • [36] Physical Modelling of Proton and Heavy Ion Radiation using Geant4
    Douglass, M.
    Bezak, E.
    HEAVY ION ACCELERATOR SYMPOSIUM ON FUNDAMENTAL AND APPLIED SCIENCE 2012, 2012, 35
  • [37] Geant4 simulation of interplanetary proton induced deep dielectrics charging
    Qin X.-G.
    He D.-Y.
    Yang S.-S.
    Wang J.
    Yuhang Xuebao/Journal of Astronautics, 2010, 31 (02): : 526 - 530
  • [38] Protons Interaction with Nomex Target: Secondary Radiation from a Monte Carlo Simulation with Geant4
    Loffredo, Filomena
    Vardaci, Emanuele
    Bianco, Davide
    Di Nitto, Antonio
    Quarto, Maria
    APPLIED SCIENCES-BASEL, 2022, 12 (05):
  • [39] Validation of Geant4 hadronic physics
    Beringer, J
    Folger, G
    Gianotti, F
    Ribon, A
    Wellisch, JP
    Barberis, D
    Cervetto, M
    Osculati, B
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 494 - 498
  • [40] DEVELOPMENT AND VALIDATION OF A GEANT4 RADIATION TRANSPORT CODE FOR CT DOSIMETRY
    Carver, D. E.
    Kost, S. D.
    Fernald, M. J.
    Lewis, K. G., II
    Fraser, N. D.
    Pickens, D. R.
    Price, R. R.
    Stabin, M. G.
    HEALTH PHYSICS, 2015, 108 (04): : 419 - 428