Validation of Geant4 10.3 simulation of proton interaction for space radiation effects

被引:24
|
作者
Ivanchenko, Vladimir [1 ,2 ]
Dondero, Paolo [3 ]
Fioretti, Valentina [4 ]
Ivantchenko, Anton [5 ]
Lei, Fan [6 ]
Lotti, Simone [7 ]
Mantero, Alfonso [3 ]
Mineo, Teresa [8 ]
机构
[1] CERN, Geneve 23, CH-1211 Geneva, Switzerland
[2] Tomsk State Univ, Leninsky Pr 36, Tomsk 634050, Russia
[3] SWHARD SRL, Via Greto Cornigliano 6R, I-16152 Genoa, Italy
[4] IASF Bologna, INAF, Via P Gobetti 101, I-40129 Bologna, Italy
[5] Geant4 Associate Int Ltd, 9 Royd Terrace, Hebden Bridge HX7 7BT, England
[6] RadMod Res, Camberley, Hants, England
[7] IAPS, INAF, Via Fosso Cavaliere 100, I-00133 Rome, Italy
[8] IASF Palermo, INAF, Via Ugo Malfa 153, I-90146 Palermo, Italy
关键词
Geant4; Monte Carlo; Validation; PRODUCTION CROSS-SECTIONS; ENERGY-LOSS; CASCADE; PHYSICS;
D O I
10.1007/s10686-017-9556-z
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Monte Carlo simulation of space radiation effects induced by protons is important for design of space missions. Geant4 is a well established toolkit for Monte Carlo simulation focused on high energy physics applications. In this work, a set of new validation results versus data for Geant4 electromagnetic and hadronic interaction of protons is presented and discussed. Optimal configuration of Geant4 physics for space applications is proposed.
引用
收藏
页码:437 / 450
页数:14
相关论文
共 50 条
  • [21] GEANT4 and its validation
    Amako, K
    Guatelli, S
    Ivanchencko, V
    Maire, M
    Mascialino, B
    Murakami, K
    Pandola, L
    Parlati, S
    Pia, MG
    Piergentili, M
    Sasaki, T
    Urban, L
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 44 - 49
  • [22] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 896 - 901
  • [23] Study of proton computed tomography using GEANT4 simulation
    Aso, Tsukasa
    Fujisaka, Katsuhiko
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 876 - 879
  • [24] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2138 - 2142
  • [25] Proton pencil beam dose distribution simulation by Geant4
    Yang, Y
    Coutrakon, G
    Wang, N
    Shahnazi, K
    Miller, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520
  • [26] NUMERICAL SIMULATION OF PROTON BACKSCATTERING SPECTRA IN GEANT4 TOOLKIT
    Lingis, D.
    Gaspariunas, M.
    Kovalevskij, V.
    Plukis, A.
    Remeikis, V.
    LITHUANIAN JOURNAL OF PHYSICS, 2024, 64 (01): : 48 - 57
  • [27] GEANT4 simulation of exit energy in proton medical imaging
    Silva, R. C. L.
    Denyak, V.
    Schelin, H. R.
    Hoff, G.
    Paschuk, S. A.
    Setti, J. A. P.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [28] GEANT4 APPLICATIONS IN SPACE
    Asai, Makoto
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 719 - 728
  • [29] Photon Elastic Scattering Simulation: Validation and Improvements to Geant4
    Batic, Matej
    Hoff, Gabriela
    Pia, Maria Grazia
    Saracco, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1636 - 1664
  • [30] Geant4 simulation of continuum
    Silva, Z.
    Ferrer, A.
    Cristancho, F.
    VII LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2007, 947 : 489 - +