Simultaneous detection of refractive index and surface charges in nanolaser biosensors

被引:34
|
作者
Watanabe, Keisuke [1 ]
Kishi, Yoji [1 ]
Hachuda, Shoji [1 ]
Watanabe, Takumi [1 ]
Sakemoto, Mai [1 ]
Nishijima, Yoshiaki [1 ]
Baba, Toshihiko [1 ]
机构
[1] Yokohama Natl Univ, Dept Elect & Comp Engn, Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
关键词
LABEL-FREE; ADSORPTION;
D O I
10.1063/1.4904481
中图分类号
O59 [应用物理学];
学科分类号
摘要
The emission intensity of a GaInAsP photonic crystal nanolaser is affected by the pH of the solution, in which the nanolaser is immersed. This phenomenon can be explained by the change in the redox potential, which modifies the filling of electrons at surface states of the semiconductor and hence the nonradiative surface recombination. This phenomenon allows the nanolaser to simultaneously and independently detect the refractive index and electric charges near the surface on the basis of the variation in emission wavelength and intensity, respectively. This paper demonstrates this function through alternate deposition of charged polyelectrolytes and hybridization of deoxyribonucleic acids. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Machine learning unveils surface refractive index dynamics in comb-like plasmonic optical fiber biosensors
    Hadrien Fasseaux
    Médéric Loyez
    Christophe Caucheteur
    Communications Engineering, 3 (1):
  • [22] Optical Detection of Motion of an Object with a Refractive Index Coinciding with the Refractive Index of the Surroundings
    N. N. Rozanov
    Optics and Spectroscopy, 2004, 96 : 938 - 939
  • [23] Assaying with PCF-based SPR refractive index biosensors: From recent configurations to outstanding detection limits
    Danlard, Iddrisu
    Akowuah, Emmanuel Kofi
    OPTICAL FIBER TECHNOLOGY, 2020, 54
  • [24] Optical detection of motion of an object with a refractive index coinciding with the refractive index of the surroundings
    Rozanov, NN
    OPTICS AND SPECTROSCOPY, 2004, 96 (06) : 938 - 939
  • [25] Surface Plasmonic Resonance Sensor for Wider Range of Low Refractive Index Detection
    Haque, Emranul
    Hossain, Md. Anwar
    Thai Pham
    Yoshinori Namihira
    Nguyen Hoang Hai
    Ahmed, Feroz
    2019 26TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS (ICT), 2019, : 479 - 484
  • [26] Sensitivity Analysis of Metasurface Array-Based Refractive Index Biosensors
    Patel, Shobhit K.
    Parmar, Juveriya
    Zakaria, Rozalina Binti
    Sharafali, A.
    Nguyen, Truong Khang
    Dhasarathan, Vigneswaran
    IEEE SENSORS JOURNAL, 2021, 21 (02) : 1470 - 1477
  • [27] Effect of the charges of impurity on the refractive index changes in parabolic quantum dot
    Huang, Jinsheng
    PHYSICA B-CONDENSED MATTER, 2013, 409 : 16 - 20
  • [28] Gas sensors for refractive index detection using surface plasmon resonance on nanosystem
    Zhao Hua-Jun
    Tian Yong-You
    Lei Ju-Hua
    INTERNATIONAL SYMPOSIUM ON PHOTONICS AND OPTOELECTRONICS 2014, 2014, 9233
  • [29] Measurement of air refractive index based on surface plasmon resonance and phase detection
    Chen, Qianghua
    Luo, Huifu
    Wang, Sumei
    Wang, Feng
    OPTICS LETTERS, 2012, 37 (14) : 2916 - 2918
  • [30] Simultaneous measurement of refractive index and temperature for prism-based surface plasmon resonance sensors