Comparison of A Priori Calibration Models for Respiratory Inductance Plethysmography During Running

被引:0
|
作者
Leutheuser, Heike [1 ]
Heyde, Christian
Gollhofer, Albert
Eskofier, Bjoern M. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, Digital Sports Grp, D-91054 Erlangen, Germany
来源
2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2014年
关键词
INDUCTIVE PLETHYSMOGRAPHY; VENTILATION; EXERCISE; VALIDATION; ABDOMEN; VOLUME;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory inductive plethysmography (RIP) has been introduced as an alternative for measuring ventilation by means of body surface displacement (diameter changes in rib cage and abdomen). Using a posteriori calibration, it has been shown that RIP may provide accurate measurements for ventilatory tidal volume under exercise conditions. Methods for a priori calibration would facilitate the application of RIP. Currently, to the best knowledge of the authors, none of the existing ambulant procedures for RIP calibration can be used a priori for valid subsequent measurements of ventilatory volume under exercise conditions. The purpose of this study is to develop and validate a priori calibration algorithms for ambulant application of RIP data recorded in running exercise. We calculated Volume Motion Coefficients (VMCs) using seven different models on resting data and compared the root mean squared error (RMSE) of each model applied on running data. Least squares approximation (LSQ) without offset of a two-degree-of-freedom model achieved the lowest RMSE value. In this work, we showed that a priori calibration of RIP exercise data is possible using VMCs calculated from 5 min resting phase where RIP and flowmeter measurements were performed simultaneously. The results demonstrate that RIP has the potential for usage in ambulant applications.
引用
收藏
页码:6393 / 6396
页数:4
相关论文
共 50 条
  • [41] Use of Computer and Respiratory Inductance Plethysmography for the Automated Detection of Swallowing in the Elderly
    Moreau-Gaudry, Alexandre
    Sabil, Abdelkebir
    Baconnier, Pierre
    Benchetrit, Gila
    Franco, Alain
    CONNECTING MEDICAL INFORMATICS AND BIO-INFORMATICS, 2005, 116 : 95 - 100
  • [42] SINGLE POSITION CALIBRATION OF THE RESPIRATORY INDUCTANCE PLETHYSMOGRAPH
    LOVERIDGE, B
    WEST, P
    ANTHONISEN, NR
    KRYGER, MH
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 127 (04): : 254 - 254
  • [43] Comparison of apnea identified by respiratory inductance plethysmography with that detected by end-tidal CO2 or thermistor
    Weese-Mayer, DE
    Corwin, MJ
    Peucker, MR
    Di Fiore, JM
    Hufford, DR
    Tinsley, LR
    Neuman, MR
    Martin, RJ
    Brooks, LJ
    Ward, SLD
    Lister, G
    Willinger, M
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (02) : 471 - 480
  • [44] QUANTIFICATION OF ABDOMINAL EXPIRATORY MOTION VIA CORRELATION OF RESPIRATORY INDUCTANCE PLETHYSMOGRAPHY AND SPIROMETRY
    Mandel, Jeff E.
    Atkins, Joshua H.
    ANESTHESIA AND ANALGESIA, 2012, 115
  • [45] Respiratory Inductance Plethysmography Improves Diagnostic Sensitivity And Specificity Of Obstructive Sleep Apnea
    Kogan, D.
    Kimbro, S.
    Gutierrez, G.
    Jain, V.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [46] Respiratory Inductance Plethysmography Improved Diagnostic Sensitivity and Specificity of Obstructive Sleep Apnea
    Kogan, Dmitriy
    Jain, Arad
    Kimbro, Shawn
    Gutierrez, Guillermo
    Jain, Vivek
    RESPIRATORY CARE, 2016, 61 (08) : 1033 - 1037
  • [47] Tidal breathing parameters in young children. Comparison of respiratory inductance plethysmography (RIP) to a facemask and pneumotachograph system (PNT).
    Manczur, TI
    Rafferty, GF
    Greenough, A
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A673 - A673
  • [48] Calibration of Respiratory Inductance Plethysmograph in Preterm Infants With Different Respiratory Conditions
    Emeriaud, Guillaume
    Eberhard, Andre
    Benchetrit, Gila
    Debillon, Thierry
    Baconnier, Pierre
    PEDIATRIC PULMONOLOGY, 2008, 43 (11) : 1135 - 1141
  • [49] Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography
    De Groote, A
    Paiva, M
    Verbandt, Y
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 90 (03) : 1025 - 1030
  • [50] SINGLE-POSITION CALIBRATION OF THE RESPIRATORY INDUCTANCE PLETHYSMOGRAPH
    LOVERIDGE, B
    WEST, P
    ANTHONISEN, NR
    KRYGER, MH
    JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (03) : 1031 - 1034