Comparison of A Priori Calibration Models for Respiratory Inductance Plethysmography During Running

被引:0
|
作者
Leutheuser, Heike [1 ]
Heyde, Christian
Gollhofer, Albert
Eskofier, Bjoern M. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, Digital Sports Grp, D-91054 Erlangen, Germany
关键词
INDUCTIVE PLETHYSMOGRAPHY; VENTILATION; EXERCISE; VALIDATION; ABDOMEN; VOLUME;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory inductive plethysmography (RIP) has been introduced as an alternative for measuring ventilation by means of body surface displacement (diameter changes in rib cage and abdomen). Using a posteriori calibration, it has been shown that RIP may provide accurate measurements for ventilatory tidal volume under exercise conditions. Methods for a priori calibration would facilitate the application of RIP. Currently, to the best knowledge of the authors, none of the existing ambulant procedures for RIP calibration can be used a priori for valid subsequent measurements of ventilatory volume under exercise conditions. The purpose of this study is to develop and validate a priori calibration algorithms for ambulant application of RIP data recorded in running exercise. We calculated Volume Motion Coefficients (VMCs) using seven different models on resting data and compared the root mean squared error (RMSE) of each model applied on running data. Least squares approximation (LSQ) without offset of a two-degree-of-freedom model achieved the lowest RMSE value. In this work, we showed that a priori calibration of RIP exercise data is possible using VMCs calculated from 5 min resting phase where RIP and flowmeter measurements were performed simultaneously. The results demonstrate that RIP has the potential for usage in ambulant applications.
引用
收藏
页码:6393 / 6396
页数:4
相关论文
共 50 条
  • [31] The utility of respiratory inductance plethysmography in REM sleep scoring during multiple sleep latency testing
    Drakatos, Panagis
    Higgins, Sean
    Duncan, Lain
    Bridle, Kate
    Briscoe, Sam
    Leschziner, Guy D.
    Kent, Brian D.
    Williams, Adrian J.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2016, 230 : 1 - 4
  • [32] Validation of Respiratory Inductance Plethysmography for Measuring Tidal Volume in Swine
    Su, Zhenbo
    Oto, Jun
    Wang, Jingwen
    Kimball, William R.
    Chenelle, Christopher T.
    Kacmarek, Robert M.
    King, David R.
    Jiang, Yandong
    Duggans, Michael J.
    COMPARATIVE MEDICINE, 2015, 65 (03) : 225 - 231
  • [33] Measures of respiratory inductance plethysmography (RIP) in children with neuromuscular disease
    Strang, Abigail
    Ryan, Lauren
    Rahman, Tariq
    Balasubramanian, Sona
    Hossain, Jobayer
    Heinle, Robert
    Shaffer, Thomas H.
    PEDIATRIC PULMONOLOGY, 2018, 53 (09) : 1260 - 1268
  • [34] A novel method of detecting the ballistocardiograph from respiratory inductance plethysmography signals recorded during sleep
    Olafsdottir, G. H.
    Finnsson, E.
    Loftsdottir, D. L.
    Jonsson, S. Ae
    Helgadottir, H.
    Agustsson, J. S.
    JOURNAL OF SLEEP RESEARCH, 2020, 29 : 197 - 197
  • [35] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY (RESPICOMP) IN LAMBS
    WARREN, RH
    FEWELL, JE
    ALDERSON, SH
    CLINICAL RESEARCH, 1983, 31 (05): : A917 - A917
  • [36] CALIBRATION OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY (RESPICOMPTM) IN INFANTS
    WARREN, RH
    ALDERSON, SH
    CLINICAL RESEARCH, 1984, 32 (05): : A909 - A909
  • [37] CALIBRATION OF RESPIRATORY INDUCTION PLETHYSMOGRAPHY (RESPITRACE) IN INFANTS
    DOLFIN, T
    DUFFTY, P
    WILKES, DL
    BRYAN, MH
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 126 (03): : 577 - 579
  • [38] Measurement of respiratory effort in sleep by 3Dcamera andrespiratory inductance plethysmography: A comparison of two methods
    Coronel, Carmina
    Wiesmeyr, Christoph
    Garn, Heinrich
    Kohn, Bernhard
    Wimmer, Markus
    Mandl, Magdalena
    Glos, Martin
    Penzel, Thomas
    Kloesch, Gerhard
    Stefanic-Kejik, Andrijana
    Boeck, Marion
    Kaniusas, Eugenijus
    Seidel, Stefan
    SOMNOLOGIE, 2019, 23 (02): : 86 - 92
  • [39] Tidal breathing parameters in young children: Comparison of measurement by respiratory inductance plethysmography to a facemask pneumotachograph system
    Manczur, T
    Greenough, A
    Hooper, R
    Allen, K
    Latham, S
    Price, JF
    Rafferty, GF
    PEDIATRIC PULMONOLOGY, 1999, 28 (06) : 436 - 441
  • [40] The characteristic patterns of breathing in asthma as measured by respiratory inductance plethysmography (RIP)
    Prys-Picard, CO
    Niven, RM
    THORAX, 2004, 59 : 51 - 51