Comparison of A Priori Calibration Models for Respiratory Inductance Plethysmography During Running

被引:0
|
作者
Leutheuser, Heike [1 ]
Heyde, Christian
Gollhofer, Albert
Eskofier, Bjoern M. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, Digital Sports Grp, D-91054 Erlangen, Germany
关键词
INDUCTIVE PLETHYSMOGRAPHY; VENTILATION; EXERCISE; VALIDATION; ABDOMEN; VOLUME;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory inductive plethysmography (RIP) has been introduced as an alternative for measuring ventilation by means of body surface displacement (diameter changes in rib cage and abdomen). Using a posteriori calibration, it has been shown that RIP may provide accurate measurements for ventilatory tidal volume under exercise conditions. Methods for a priori calibration would facilitate the application of RIP. Currently, to the best knowledge of the authors, none of the existing ambulant procedures for RIP calibration can be used a priori for valid subsequent measurements of ventilatory volume under exercise conditions. The purpose of this study is to develop and validate a priori calibration algorithms for ambulant application of RIP data recorded in running exercise. We calculated Volume Motion Coefficients (VMCs) using seven different models on resting data and compared the root mean squared error (RMSE) of each model applied on running data. Least squares approximation (LSQ) without offset of a two-degree-of-freedom model achieved the lowest RMSE value. In this work, we showed that a priori calibration of RIP exercise data is possible using VMCs calculated from 5 min resting phase where RIP and flowmeter measurements were performed simultaneously. The results demonstrate that RIP has the potential for usage in ambulant applications.
引用
收藏
页码:6393 / 6396
页数:4
相关论文
共 50 条
  • [1] EVALUATION OF VARIOUS MODELS FOR RESPIRATORY INDUCTANCE PLETHYSMOGRAPHY CALIBRATION
    STROMBERG, NOT
    DAHLBACK, GO
    GUSTAFSSON, PM
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (03) : 1206 - 1211
  • [2] Respiratory inductance plethysmography in healthy infants: a comparison of three calibration methods
    Poole, KA
    Thompson, JR
    Hallinan, HM
    Beardsmore, CS
    EUROPEAN RESPIRATORY JOURNAL, 2000, 16 (06) : 1084 - 1090
  • [3] RESPIRATORY INDUCTANCE PLETHYSMOGRAPHY - CALIBRATION TECHNIQUES, THEIR VALIDATION AND THE EFFECTS OF POSTURE
    STRADLING, JR
    CHADWICK, GA
    QUIRK, C
    PHILLIPS, T
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1985, 21 (04): : 317 - 324
  • [4] Adaptive Accelerometry Derived Respiration: Comparison with Respiratory Inductance Plethysmography during Sleep
    Bricout, Aurelien
    Fontecave-Jallon, Julie
    Colas, Damien
    Gerard, Gregoire
    Pepin, Jean-Louis
    Gumery, Pierre-Yves
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6714 - 6717
  • [5] Flowmetric comparison of respiratory inductance plethysmography and pneumotachography in horses
    Hoffman, A
    Kuehn, H
    Riedelberger, K
    Kupcinskas, R
    Miskovic, MB
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (06) : 2767 - 2775
  • [6] Respiratory inductance plethysmography calibration for pediatric upper airway obstruction: an animal model
    Khemani, Robinder G.
    Flink, Rutger
    Hotz, Justin
    Ross, Patrick A.
    Ghuman, Anoopindar
    Newth, Christopher J. L.
    PEDIATRIC RESEARCH, 2015, 77 (01) : 75 - 83
  • [7] Respiratory inductance plethysmography calibration for pediatric upper airway obstruction: an animal model
    Robinder G. Khemani
    Rutger Flink
    Justin Hotz
    Patrick A. Ross
    Anoopindar Ghuman
    Christopher J.L. Newth
    Pediatric Research, 2015, 77 : 75 - 83
  • [8] Respiratory Inductance Plethysmography-A Rationale for Validity during Exercise
    Heyde, Christian
    Leutheuser, Heike
    Eskofier, Bjoern
    Roecker, Kai
    Gollhofer, Albert
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (03): : 488 - 495
  • [9] Respiratory Inductance Plethysmography to Assess Fatigability during Repetitive Work
    Silva, Luis
    Dias, Mariana
    Folgado, Duarte
    Nunes, Maria
    Namburi, Praneeth
    Anthony, Brian
    Carvalho, Diogo
    Carvalho, Miguel
    Edelman, Elazer
    Gamboa, Hugo
    SENSORS, 2022, 22 (11)
  • [10] SIMPLIFYING THE USE OF RESPIRATORY INDUCTANCE PLETHYSMOGRAPHY
    STRADLING, JR
    CHADWICK, GA
    QUIRK, C
    PHILLIPS, T
    THORAX, 1984, 39 (03) : 233 - 234