Comparison of conventional tube test with diamed gel microcolumn assay for anti-D titration

被引:19
|
作者
Novaretti, MCZ
Jens, E
Pagliarini, T
Bonifácio, SL
Dorlhiac-Llacer, PE
Chamone, DAF
机构
[1] Univ Sao Paulo, Dept Hematol, Sao Paulo, Brazil
[2] Fdn Pro Sangue Hemoctr Sao Paulo, Immunohematol Dept, Sao Paulo, Brazil
来源
CLINICAL AND LABORATORY HAEMATOLOGY | 2003年 / 25卷 / 05期
关键词
gel test; antibody titration; anti-D; haemolytic disease of the newborn; alloantibodies;
D O I
10.1046/j.1365-2257.2003.00540.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Anti-D titration is the first step in the evaluation of the RhD-sensitized patient. Traditionally, anti-D titration has been performed by tube agglutination. Gel microcolumn assay is a method that has gained widespread usage throughout the world, mainly for ABO/Rh typing, unexpected antibody screening and direct antiglobulin tests. As gel assay has become widely used as a routine method to detect red blood cell alloantibodies, a critical anti-D titer needs to be established. Seventy-nine known blood samples with anti-D (titers 1-32) were titrated simultaneously by the conventional tube test and the gel microcolumn assay. Red blood cells (R(o)r phenotype) were used, with a final concentration of 3% for tube and 0.8% for gel. Serial twofold dilutions (2-2.048) were prepared for each technique, followed by reading in antiglobulin phase. Anti-D titration in the gel microcolumn assay showed significantly higher titers (mean 3.4-fold) than the conventional tube test in all samples studied. Based on these data, it was not possible to determine a critical titer for anti-D titration by the gel microcolumn assay.
引用
收藏
页码:311 / 315
页数:5
相关论文
共 50 条
  • [31] A TUBE TEST FOR RH TYPING USING PAPAIN AND INCOMPLETE ANTI-D - REPORT OF 2 SEPARATE TRIALS
    STAPLETON, RR
    MOORE, BPL
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1959, 54 (04): : 640 - 643
  • [32] 'Old is gold' does conventional test tube method still reign supreme? An immuno-haematological survey of anti-D detection and titration in ante-natal cases among major hospitals across India
    Pandey, Prashant
    Marik, Arghyadeep
    Tiwari, Aseem
    Das, Sudipta Shekhar
    Shastry, Shamee
    Chowdhry, Mohit
    Kumari, Supriya
    TRANSFUSION MEDICINE, 2024, 34 (04) : 278 - 286
  • [33] Inclusion of control test with anti-D pretransfusion testing
    Padget, BJ
    Hannon, JL
    TRANSFUSION, 2001, 41 (09) : 109S - 110S
  • [34] INTERNATIONAL COLLABORATIVE STUDY OF ASSAY OF ANTI-D (ANTI-RHO) IMMUNOGLOBULIN
    BANGHAM, DR
    KIRKWOOD, TBL
    WYBROW, G
    HUGHESJONES, NC
    GUNSON, HH
    BRITISH JOURNAL OF HAEMATOLOGY, 1978, 38 (03) : 407 - 423
  • [35] EFFECT OF DITHIOTHREITOL TREATMENT OF PLASMA ON AUTOMATED ANTI-D ASSAY
    ASHFORD, PR
    LOVE, M
    PAYNE, SG
    VOX SANGUINIS, 1985, 49 (02) : 121 - 125
  • [36] Comparison of the modified antiglobulin tube and gel microcolumn agglutination methods for testing acid eluates
    Pitts, RM
    Mueller, D
    Selbie, L
    Middleton, L
    Thomas, W
    TRANSFUSION, 2003, 43 (09) : 103A - 104A
  • [37] Comparison of the tube test and column agglutination techniques for anti-A/-B antibody titration in healthy individuals
    Matsuura, Hideaki
    Akatsuka, Yoshiki
    Matsuno, Takahiro
    Sugiura, Yukari
    Arakawa, Shoko
    Oikawa, Shota
    Yoshida, Jumpei
    Kosugi, Mitsuaki
    Emi, Nobuhiko
    VOX SANGUINIS, 2018, 113 (08) : 787 - 794
  • [38] Performance of acid elution test by conventional tube test technique and gel test.
    Novaretti, MCZ
    Silveira, EJ
    Bonifacio, SL
    Dorlhiac-Llacer, PE
    Chamone, D
    TRANSFUSION, 2002, 42 (09) : 110S - 110S
  • [39] COMPOSITION OF SEVERAL COMMERCIAL RAPID TUBE AND SALINE ANTI-D REAGENTS
    HOWARD, PL
    DOPP, SL
    TRANSFUSION, 1974, 14 (03) : 270 - 271
  • [40] EFFECT OF AMBIENT-TEMPERATURE ON ANTI-D ASSAY USING AUTOANALYZER
    GUNSON, HH
    PHILLIPS, PK
    STRATTON, F
    JOURNAL OF CLINICAL PATHOLOGY, 1974, 27 (05) : 356 - 358