Comparison of conventional tube test with diamed gel microcolumn assay for anti-D titration

被引:19
|
作者
Novaretti, MCZ
Jens, E
Pagliarini, T
Bonifácio, SL
Dorlhiac-Llacer, PE
Chamone, DAF
机构
[1] Univ Sao Paulo, Dept Hematol, Sao Paulo, Brazil
[2] Fdn Pro Sangue Hemoctr Sao Paulo, Immunohematol Dept, Sao Paulo, Brazil
来源
CLINICAL AND LABORATORY HAEMATOLOGY | 2003年 / 25卷 / 05期
关键词
gel test; antibody titration; anti-D; haemolytic disease of the newborn; alloantibodies;
D O I
10.1046/j.1365-2257.2003.00540.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Anti-D titration is the first step in the evaluation of the RhD-sensitized patient. Traditionally, anti-D titration has been performed by tube agglutination. Gel microcolumn assay is a method that has gained widespread usage throughout the world, mainly for ABO/Rh typing, unexpected antibody screening and direct antiglobulin tests. As gel assay has become widely used as a routine method to detect red blood cell alloantibodies, a critical anti-D titer needs to be established. Seventy-nine known blood samples with anti-D (titers 1-32) were titrated simultaneously by the conventional tube test and the gel microcolumn assay. Red blood cells (R(o)r phenotype) were used, with a final concentration of 3% for tube and 0.8% for gel. Serial twofold dilutions (2-2.048) were prepared for each technique, followed by reading in antiglobulin phase. Anti-D titration in the gel microcolumn assay showed significantly higher titers (mean 3.4-fold) than the conventional tube test in all samples studied. Based on these data, it was not possible to determine a critical titer for anti-D titration by the gel microcolumn assay.
引用
收藏
页码:311 / 315
页数:5
相关论文
共 50 条
  • [21] REFERENCE PREPARATION FOR ASSAY OF ANTI-D IMMUNOGLOBULIN
    GUNSON, HH
    THOMAS, DP
    LANCET, 1979, 1 (8108): : 162 - 162
  • [22] Characterization of Prenatal Anti-D Titers by Gel Versus Tube Method: A Meta-Analysis
    Lieberman, Lani
    Andrews, Jennifer
    Adkins, Brian D.
    Evans, Micahel
    Cohn, Claudia S.
    TRANSFUSION, 2019, 59 : 161A - 161A
  • [23] A comparison of conventional tube technique and gel technique in evaluation of direct antiglobulin test
    Khetan, D.
    Chaudhary, R.
    Das, S.
    VOX SANGUINIS, 2006, 91 : 117 - 117
  • [24] ANTI-D TREATMENT IN THROMBOCYTOPENIA REFRACTORY TO CONVENTIONAL THERAPIES
    ADORNO, G
    LOPINTO, FR
    COX, MC
    BRUNO, A
    MASI, M
    STIPA, E
    MONTANARO, M
    PAPA, G
    HAEMATOLOGICA, 1992, 77 (01) : 97 - 98
  • [25] Comparative study of 49 anti-D antibodies in tube and gel techniques with 22 partial D red blood cells
    Beolet, M
    Betremieux, C
    Delbar, A
    Keyser, L
    Hennion, M
    Martel, S
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 1996, 3 (06) : 373 - 380
  • [26] OBSERVATIONS ON REPRODUCIBILITY OF BROMELIZED TEST CELL ANTI-D ASSAY USING AUTO-ANALYSER
    GUNSON, HH
    PHILLIPS, PK
    STRATTON, F
    VOX SANGUINIS, 1974, 26 (04) : 334 - 343
  • [27] Comparative Evaluation of the Microcolumn Gel Card Test and the Conventional Tube Test for Measurement of Titres of Immunoglobulin G Antibodies to Blood Group A and Blood Group B
    Cheng, D.
    Hao, Y.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2011, 39 (03) : 934 - 943
  • [28] ASSAY OF ANTI-D ACTIVITY BY 2 RADIOIMMUNOASSAY TECHNIQUES USING PURIFIED I-125-LABELLED ANTI-D
    HUGHESJONES, NC
    GARDNER, B
    HUNT, V
    NORLEY, I
    VOX SANGUINIS, 1971, 21 (05) : 425 - +
  • [29] Comparison of methods for detection of antenatal anti-D
    Klostermann, D. A.
    Puca, K. E.
    Scott, E. A.
    Johnson, S. T.
    TRANSFUSION, 2006, 46 (09) : 148A - 148A
  • [30] Comparison of scangel, diamed, in-house SPAT and tube liss antiglobulin test for antibody detection
    Mohabir, L. A.
    Womersley, C.
    VOX SANGUINIS, 2006, 91 : 121 - 121