Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:6
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
ASCORBIC-ACID; HUMAN-PLASMA; FORMULATIONS; PARACETAMOL; OXIDATION; PHOSPHATE; MORPHINE; URINE;
D O I
10.1155/2015/626458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 mu M (0.15 mg.L-1) to 15 mu M (4.5 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 120 s is as low as 4.5 mu g.L-1. The repeatability of the method at a 0.6 mu g.L-1 concentration level, expressed as the RSD, is 3.7% (for n = 5). The method was successfully applied and validated by analyzing codeine in drug, human plasma, and urine samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Antunovic, Vesna
    Tripkovic, Tatjana
    Tomasevic, Biljana
    Baosic, Rada
    Jelic, Dijana
    Lolic, Aleksandar
    ANALYTICAL SCIENCES, 2021, 37 (02) : 353 - 358
  • [42] Simultaneous voltammetric determination of paracetamol and domperidone based on a graphene/platinum nanoparticles/nafion composite modified glassy carbon electrode
    Kalambate, Pramod K.
    Sanghavi, Bankim J.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 285 - 294
  • [43] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [44] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Xu, Ying
    Wang, Fei
    Wang, Le
    Zhao, Fangyuan
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1473 - 1480
  • [45] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Ying Xu
    Fei Wang
    Le Wang
    Fangyuan Zhao
    Baocheng Yang
    Baoxian Ye
    Journal of Solid State Electrochemistry, 2012, 16 : 1473 - 1480
  • [46] Electrochemical determination of bisphenol A based on PHD/MWCNTs modified glassy carbon electrode
    Yi, Jie
    Tang, Shuai
    Wang, Zhou
    Yin, Yefeng
    Yang, Sui
    Zhang, Bingxing
    Shu, Shi
    Liu, Tingya
    Xu, Lu
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (02) : 158 - 174
  • [47] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    ANALYST, 2002, 127 (01) : 129 - 134
  • [48] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [49] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    延边大学学报(自然科学版), 2000, (02) : 110 - 112
  • [50] Voltammetric Determination of Caffeine at Pt/Carbon Nanotubes Composite Modified Glassy Carbon Electrode
    Wei, Yingliang
    Zhang, Luping
    Shao, Chen
    Li, Chao
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 607 - 617