Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:6
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
ASCORBIC-ACID; HUMAN-PLASMA; FORMULATIONS; PARACETAMOL; OXIDATION; PHOSPHATE; MORPHINE; URINE;
D O I
10.1155/2015/626458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 mu M (0.15 mg.L-1) to 15 mu M (4.5 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 120 s is as low as 4.5 mu g.L-1. The repeatability of the method at a 0.6 mu g.L-1 concentration level, expressed as the RSD, is 3.7% (for n = 5). The method was successfully applied and validated by analyzing codeine in drug, human plasma, and urine samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] VOLTAMMETRIC DETERMINATION OF METHYLPARABAN IN COSMETICS USING A MULTI-WALL CARBON NANOTUBES/NAFION COMPOSITE MODIFIED GLASSY CARBON ELECTRODE
    Luo, Peili
    Liu, Jie
    Li, Yamin
    Miao, Yurui
    Ye, Baoxian
    ANALYTICAL LETTERS, 2012, 45 (16) : 2445 - 2454
  • [32] Electrochemical Determination of Phenylethanolamine A Based on Nafion/MWCNTs/AuNPs Modified Carbon Electrode
    Lai, Yanjun
    Bai, Jing
    Zhu, Wei
    Xian, Yuezhong
    Jin, Litong
    CHINESE JOURNAL OF CHEMISTRY, 2013, 31 (02) : 221 - 229
  • [33] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    Baranowska, I.
    Bijak, K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) : 891 - 895
  • [35] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [36] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [37] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519
  • [38] Voltammetric Determination of Epinephrine using a Thiourea Modified Glassy Carbon Electrode
    Yazdely, Malihe Ahmadian
    Taher, Mohammad Ali
    Tajik, Somayeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (04): : 517 - 527
  • [39] Diaminoanthraquinone polymer modified glassy carbon electrode for the voltammetric determination of imidacloprid
    Soman, Sithara
    Ramakrishnan, Kala
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (12) : 2831 - 2843
  • [40] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Vesna Antunović
    Tatjana Tripković
    Biljana Tomašević
    Rada Baošić
    Dijana Jelić
    Aleksandar Lolić
    Analytical Sciences, 2021, 37 (2) : 353 - 358