Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using Anterior Segment Optical Coherence Tomography

被引:12
|
作者
Amato, Domenico [1 ]
Lombardo, Marco [1 ]
Oddone, Francesco [1 ]
Nubile, Mario [2 ]
Gisoldi, Rossella A. M. Colabelli [3 ]
Villani, Carlo M. [3 ]
Yoo, Sonia [4 ]
Parel, Jean-Marie [4 ]
Pocobelli, Augusto [3 ]
机构
[1] IRCCS, Fdn G B Bietti, I-00184 Rome, Italy
[2] Univ G dAnnunzio, Dept Med & Ageing Sci, Ophthalmol Clin, Pescara, Italy
[3] S Giovanni Addolorata Britann Hosp, Rome, Italy
[4] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL USA
关键词
ENDOTHELIAL KERATOPLASTY; ULTRASOUND PACHYMETRY; PRECUT TISSUE; ORBSCAN-II; VISANTE;
D O I
10.1136/bjo.2010.190595
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To preliminarily evaluate the repeatability of central corneal thickness (CCT) measurements performed with Anterior Segment Optical Coherence Tomography (AS-OCT) on eye bank posterior corneal lenticules. Methods Six donor lenticules were created with a 350 mu m head microkeratome (Moria, Antony, France). All donor tissues were stored at 4 degrees C in Eusol-C solution (Alchimia S.r.l, Ponte S. Nicolo, Italy), without the anterior cornea lamella. The CCT of each lenticule, maintained in the glass phial, was measured using a commercial AS-OCT instrument (Visante, Carl Zeiss Meditec, Dublin, California, USA) and a specially designed adaptor immediately and 4, 24 and 48 hours after dissection. Immediately after AS-OCT, CCT values were measured with the ultrasound pachymetry method used at the Eye Bank. Results The mean donor cornea central thickness was 647 +/- 636 mu m and 660 +/- 38 mu m (p = 0.001) as measured by AS-OCT and ultrasound, respectively; immediately after dissection, CCT values of posterior lenticules were 235 +/- 643 mu m and 248 +/- 44 mu m, respectively (p = 0.001). No statistically significant changes in CCT values of donor lenticules were assessed over the 48 h period with both methods. There was a high level of agreement, evidenced by Bland-Altman analysis, between the two methods of pachymetry. Conclusion AS-OCT, with the corneal tissue in the vial, was revealed to be a repeatable and reliable method for measuring posterior donor lenticule central thickness. Lenticule CCT values measured with the investigational AS-OCT method were on average 10 mu m thinner than those measured with the established ultrasound method.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [41] Anterior Segment Optical Coherence Tomography Features of Acute Corneal Hydrops
    Basu, Sayan
    Vaddavalli, Pravin K.
    Vemuganti, Geeta K.
    Ali, Md Hasnat
    Murthy, Somasheila I.
    CORNEA, 2012, 31 (05) : 479 - 485
  • [42] Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
    Wongchaisuwat, Nida
    Metheetrairat, Ankana
    Chonpimai, Pratuangsri
    Nujoi, Waree
    Prabhasawat, Pinnita
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1865 - 1873
  • [43] The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography
    Wang, JH
    Fonn, D
    Simpson, TL
    Jones, L
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (03) : 315 - 319
  • [44] The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    Sin, Sokpheaktra
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (06) : 360 - 365
  • [45] Dependability of Posterior-Segment Spectral Domain Optical Coherence Tomography for Measuring Central Corneal Thickness
    Correa-Perez, Maria E.
    Olmo, Natalia
    Lopez-Miguel, Alberto
    Fernandez, Itziar
    Coco-Martin, Mara B.
    Maldonado, Miguel J.
    CORNEA, 2014, 33 (11) : 1219 - 1224
  • [46] Evaluation of the Central Corneal Thickness with Anterior Segment Optical Coherence Tomogram after Penetrating Keratoplasty
    Raj, Anuradha
    Dhasmana, Renu
    Bahadur, Harsh
    Nagpal, Ramesh Chander
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (10) : NC5 - NC8
  • [47] Comparison of Scheimpflug Corneal Tomography and Anterior Segment Optical Coherence Tomography Measurements in Corneal Cystinosis: A Case Series
    Vercauteren, Leonie
    Consejo, Alejandra
    De Vries, Meindert Jan
    Krolo, Iva
    Koppen, Carina
    Dhubhghaill, Sorcha Ni
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (07): : 321 - 328
  • [48] Age-related differences in corneal epithelial thickness measurements with anterior segment optical coherence tomography
    Bong Jun Kim
    Ik-Hee Ryu
    Sun Woong Kim
    Japanese Journal of Ophthalmology, 2016, 60 : 357 - 364
  • [49] Anterior segment optical coherence tomography and ultrasound biomicroscopy for measuring thickness of corneal and bulbar conjunctival tumours
    Lauwers, Noemie
    Janssens, Katleen
    Mertens, Michelle
    Mathysen, Danny
    Lammens, Martin
    de Keizer, Rob J. W.
    De Groot, Veva
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (06) : 760 - 764
  • [50] Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    Zhao, Paul S.
    Wong, Tien Yin
    Wong, Wan-Ling
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1047 - 1049