Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using Anterior Segment Optical Coherence Tomography

被引:12
|
作者
Amato, Domenico [1 ]
Lombardo, Marco [1 ]
Oddone, Francesco [1 ]
Nubile, Mario [2 ]
Gisoldi, Rossella A. M. Colabelli [3 ]
Villani, Carlo M. [3 ]
Yoo, Sonia [4 ]
Parel, Jean-Marie [4 ]
Pocobelli, Augusto [3 ]
机构
[1] IRCCS, Fdn G B Bietti, I-00184 Rome, Italy
[2] Univ G dAnnunzio, Dept Med & Ageing Sci, Ophthalmol Clin, Pescara, Italy
[3] S Giovanni Addolorata Britann Hosp, Rome, Italy
[4] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL USA
关键词
ENDOTHELIAL KERATOPLASTY; ULTRASOUND PACHYMETRY; PRECUT TISSUE; ORBSCAN-II; VISANTE;
D O I
10.1136/bjo.2010.190595
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To preliminarily evaluate the repeatability of central corneal thickness (CCT) measurements performed with Anterior Segment Optical Coherence Tomography (AS-OCT) on eye bank posterior corneal lenticules. Methods Six donor lenticules were created with a 350 mu m head microkeratome (Moria, Antony, France). All donor tissues were stored at 4 degrees C in Eusol-C solution (Alchimia S.r.l, Ponte S. Nicolo, Italy), without the anterior cornea lamella. The CCT of each lenticule, maintained in the glass phial, was measured using a commercial AS-OCT instrument (Visante, Carl Zeiss Meditec, Dublin, California, USA) and a specially designed adaptor immediately and 4, 24 and 48 hours after dissection. Immediately after AS-OCT, CCT values were measured with the ultrasound pachymetry method used at the Eye Bank. Results The mean donor cornea central thickness was 647 +/- 636 mu m and 660 +/- 38 mu m (p = 0.001) as measured by AS-OCT and ultrasound, respectively; immediately after dissection, CCT values of posterior lenticules were 235 +/- 643 mu m and 248 +/- 44 mu m, respectively (p = 0.001). No statistically significant changes in CCT values of donor lenticules were assessed over the 48 h period with both methods. There was a high level of agreement, evidenced by Bland-Altman analysis, between the two methods of pachymetry. Conclusion AS-OCT, with the corneal tissue in the vial, was revealed to be a repeatable and reliable method for measuring posterior donor lenticule central thickness. Lenticule CCT values measured with the investigational AS-OCT method were on average 10 mu m thinner than those measured with the established ultrasound method.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [31] Correspondence: Comparison of Central Corneal Thickness using Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry
    De Bernardo, Maddalena
    Rosa, Nicola
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (03) : NL01 - NL01
  • [32] New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography
    Yu Wang, Xiao
    Zhang, Tian Qiao
    Rahul Rachwani, Anil
    Blanco-Dominguez, Irene
    Rocha de Lossada, Carlos
    Manuel Adan-Civiera, Afredo
    Peraza-Nieves, Jorge
    EYE, 2022, 36 (08) : 1675 - 1680
  • [33] Evaluation of Limbal and Central Corneal Epithelium Thickness in Healthy Subjects using Anterior Segment Optic Coherence Tomography
    Bozkurt, Tahir Kansu
    Perez, Carolina Aravena
    Chuephanich, Pichaya
    Supiyaphun, Chantaka
    Deng, Sophie Xiaohui
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [34] Utility of Anterior Segment Optical Coherence Tomography in the Management of Corneal Transplantation
    Takefumi Yamaguchi
    Jun Shimazaki
    Current Ophthalmology Reports, 2016, 4 (4) : 252 - 264
  • [35] New algorithm for corneal densitometry assessment based on anterior segment optical coherence tomography
    Xiao Yu Wang
    Tian Qiao Zhang
    Anil Rahul Rachwani
    Irene Blanco-Domínguez
    Carlos Rocha de Lossada
    Afredo Manuel Adán-Civiera
    Jorge Peraza-Nieves
    Eye, 2022, 36 : 1675 - 1680
  • [36] Longitudinal evaluation of posterior corneal power by anterior segment optical coherence tomography 18 months following photorefractive keratectomy
    Latifi, Golshan
    Jabbarvand, Mahmoud
    Davoodabadi, Mahmood
    Abdi, Parisa
    Mohammadi, S. Saeed
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (08): : 1159 - 1164
  • [37] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Lang, Stefan J.
    Heinzelmann, Sonja
    Boehringer, Daniel
    Reinhard, Thomas
    Maier, Philip
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2617 - 2625
  • [38] Anterior Segment Optical Coherence Tomography Findings in Corneal Blood Staining
    Mansoori, Tarannum
    Srirampur, Arjun
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (01): : 95 - 95
  • [39] Indications for intraoperative anterior segment optical coherence tomography in corneal surgery
    Stefan J. Lang
    Sonja Heinzelmann
    Daniel Böhringer
    Thomas Reinhard
    Philip Maier
    International Ophthalmology, 2020, 40 : 2617 - 2625
  • [40] Reliability of corneal topographic analysis with anterior segment optical coherence tomography
    Huang, Jinhai
    Wang, Qinmei
    Pesudovs, Konrad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (03): : 560 - 560