A design-based model of the aortic valve for fluid-structure interaction

被引:17
|
作者
Kaiser, Alexander D. [1 ,2 ,3 ]
Shad, Rohan [3 ,4 ]
Hiesinger, William [3 ,4 ]
Marsden, Alison L. [1 ,2 ,3 ,5 ]
机构
[1] Stanford Univ, Inst Computat & Math Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Pediat Cardiol, Stanford, CA 94305 USA
[3] Stanford Cardiovasc Inst, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
Aortic valve; Aortic valve mechanics; Immersed boundary method; Aortic valve fluid-structure interaction; Aortic valve modeling; Heart valve modeling; BIAXIAL MECHANICAL-PROPERTIES; IMMERSED BOUNDARY MODEL; HEART-VALVE; PART I; DYNAMICS; CUSP; STRESS;
D O I
10.1007/s10237-021-01516-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a new method for modeling the mechanics of the aortic valve and simulates its interaction with blood. As much as possible, the model construction is based on first principles, but such that the model is consistent with experimental observations. We require that tension in the leaflets must support a pressure, then derive a system of partial differential equations governing its mechanical equilibrium. The solution to these differential equations is referred to as the predicted loaded configuration; it includes the loaded leaflet geometry, fiber orientations and tensions needed to support the prescribed load. From this configuration, we derive a reference configuration and constitutive law. In fluid-structure interaction simulations with the immersed boundary method, the model seals reliably under physiological pressures and opens freely over multiple cardiac cycles. Further, model closure is robust to extreme hypo- and hypertensive pressures. Then, exploiting the unique features of this model construction, we conduct experiments on reference configurations, constitutive laws and gross morphology. These experiments suggest the following conclusions: (1) The loaded geometry, tensions and tangent moduli primarily determine model function. (2) Alterations to the reference configuration have little effect if the predicted loaded configuration is identical. (3) The leaflets must have sufficiently nonlinear material response to function over a variety of pressures. (4) Valve performance is highly sensitive to free edge length and leaflet height. These conclusions suggest appropriate gross morphology and material properties for the design of prosthetic aortic valves. In future studies, our aortic valve modeling framework can be used with patient-specific models of vascular or cardiac flow.
引用
收藏
页码:2413 / 2435
页数:23
相关论文
共 50 条
  • [41] A two-dimensional fluid-structure interaction model of the aortic value
    De Hart, J
    Peters, GWM
    Schreurs, PJG
    Baaijens, FPT
    JOURNAL OF BIOMECHANICS, 2000, 33 (09) : 1079 - 1088
  • [42] INVESTIGATION OF LEAFLET GEOMETRY IN A PERCUTANEOUS AORTIC VALVE WITH THE USE OF FLUID-STRUCTURE INTERACTION SIMULATION
    Van Aswegen, K. H. J.
    Smuts, A. N.
    Scheffer, C.
    Weich, H. S. Vh
    Doubell, A. F.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2012, 12 (01)
  • [43] Biomechanical Assessment of Bicuspid Aortic Valve Phenotypes: A Fluid-Structure Interaction Modelling Approach
    de Oliveira, Diana M. C.
    Abdullah, Nazirul
    Green, Naomi C.
    Espino, Daniel M.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2020, 11 (04) : 431 - 447
  • [44] The impact of calcification patterns in transcatheter aortic valve performance: a fluid-structure interaction analysis
    Luraghi, Giulia
    Matas, Jose Felix Rodriguez
    Beretta, Marta
    Chiozzi, Nicole
    Iannetti, Laura
    Migliavacca, Francesco
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (04) : 375 - 383
  • [45] Fluid-structure interaction simulation of the three-leaflet aortic valve using COMSOL
    Xu, Xiaoyang
    Cheng, Jie
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [46] A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve
    De Hart, J
    Baaijens, FPT
    Peters, GWM
    Schreurs, PJG
    JOURNAL OF BIOMECHANICS, 2003, 36 (05) : 699 - 712
  • [47] A fluid–structure interaction model of the aortic valve with coaptation and compliant aortic root
    Gil Marom
    Rami Haj-Ali
    Ehud Raanani
    Hans-Joachim Schäfers
    Moshe Rosenfeld
    Medical & Biological Engineering & Computing, 2012, 50 : 173 - 182
  • [48] A parametric study regarding structural design of a bioprosthetic aortic valve by 3D fluid-structure interaction simulations
    Kim, Yongwoo
    Pyo, Won Kyung
    Kim, Wan Kee
    Suh, Ga-Young
    Kang, Keonwook
    Lee, Seung Hyun
    HELIYON, 2024, 10 (06)
  • [49] Analysis of a coupled fluid-structure interaction model of the left atrium and mitral valve
    Feng, Liuyang
    Gao, Hao
    Griffith, Boyce
    Niederer, Steven
    Luo, Xiaoyu
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (11)
  • [50] Fluid-Structure Interaction Analysis of Bioprosthetic Heart Valve
    Shen, B. S.
    Yuan, Q.
    Zhang, X.
    Zhang, X.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND INFORMATION TECHNOLOGY (SEIT2015), 2016, : 118 - 122