Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases

被引:0
|
作者
Ventura, Tiago [1 ,2 ,3 ]
Rocha, Humberto [3 ,4 ,5 ]
Ferreira, Brigida da Costa [3 ,6 ,7 ]
Dias, Joana [3 ,4 ,5 ]
Lopes, Maria do Carmo [2 ,3 ,7 ]
机构
[1] Univ Aveiro, Phys Dept, Aveiro, Portugal
[2] Portuguese Oncol Inst Coimbra Francisco Gentil, EPE, Med Phys Dept, Coimbra, Portugal
[3] Inst Syst Engn & Comp Coimbra, Coimbra, Portugal
[4] Univ Coimbra, Econ Fac, Coimbra, Portugal
[5] Ctr Business & Econ Res, Coimbra, Portugal
[6] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, Lisbon, Portugal
[7] Univ Aveiro, I3N Phys Dept, Aveiro, Portugal
关键词
Beam angle optimization; Non-coplanar; Arc trajectory; VMAT; PARTIAL BREAST IRRADIATION; RADIATION-THERAPY; ANGLE OPTIMIZATION; ORIENTATION OPTIMIZATION; SINGLE-ARC; IMRT; COUCH; SELECTION; COPLANAR; ROTATION;
D O I
10.1007/s13246-021-01061-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two methods for non-coplanar beam direction optimization, one for static beams and another for arc trajectories, were proposed for intracranial tumours. The results of the beam angle optimizations were compared with the beam directions used in the clinical plans. Ten meningioma cases already treated were selected for this retrospective planning study. Algorithms for non-coplanar beam angle optimization (BAO) and arc trajectory optimization (ATO) were used to generate the corresponding plans. A plan quality score, calculated by a graphical method for plan assessment and comparison, was used to guide the beam angle optimization process. For each patient, the clinical plans (CLIN), created with the static beam orientations used for treatment, and coplanar VMAT approximated plans (VMAT) were also generated. To make fair plan comparisons, all plan optimizations were performed in an automated multicriteria calculation engine and the dosimetric plan quality was assessed. BAO and ATO plans presented, on average, moderate global plan score improvements over VMAT and CLIN plans. Nevertheless, while BAO and CLIN plans assured a more efficient OARs sparing, the ATO and VMAT plans presented a higher coverage and conformity of the PTV. Globally, all plans presented high-quality dose distributions. No statistically significant quality differences were found, on average, between BAO, ATO and CLIN plans. However, automated plan solution optimizations (BAO or ATO) may improve plan generation efficiency and standardization. In some individual patients, plan quality improvements were achieved with ATO plans, demonstrating the possible benefits of this automated optimized delivery technique.
引用
收藏
页码:1273 / 1283
页数:11
相关论文
共 48 条
  • [21] A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer
    Yuri Jeong
    Sang-wook Lee
    Jungwon Kwak
    Ilsung Cho
    Sang Min Yoon
    Jong Hoon Kim
    Jin-hong Park
    Eun Kyung Choi
    Si Yeol Song
    Young Seok Kim
    Su Ssan Kim
    Ji Hyeon Joo
    Seung Do Ahn
    Radiation Oncology, 9
  • [22] Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis
    Torizuka, Daichi
    Uto, Megumi
    Takehana, Keiichi
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1114 - 1119
  • [23] Intensity modulated radiation therapy (IMRT) with non-coplanar beams for brain tumor treatment, clinical experience
    de Carcer, PB
    Venencia, D
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S331 - S331
  • [24] Non-coplanar trajectories to improve organ at risk sparing in volumetric modulated arc therapy for primary brain tumors
    Smyth, Gregory
    Evans, Philip M.
    Bamber, Jeffrey C.
    Mandeville, Henry C.
    Welsh, Liam C.
    Saran, Frank H.
    Bedford, James L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 121 (01) : 124 - 131
  • [25] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [26] Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy
    Gayen, Sanjib
    Kombathula, Harsha
    Manna, Sumanta
    Varshney, Sonal
    Pareek, Puneet
    RADIATION ONCOLOGY JOURNAL, 2020, 38 (02): : 138 - 147
  • [27] A Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT) and Non-Coplanar Intensity Modulated Radiation Therapy (IMRT) for Nasal Cavity and Paranasal Sinus Cancer
    Jeong, Y.
    Lee, S.
    Kwak, J.
    Cho, I.
    Yoon, S.
    Kim, J.
    Park, J.
    Choi, E.
    Song, S.
    Kim, Y.
    Kim, S.
    Joo, J.
    Ahn, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S865 - S865
  • [28] A novel technique for post-mastectomy breast irradiation utilising non-coplanar intensity-modulated radiation therapy
    Koshy, M.
    Zhang, B.
    Naqvi, S.
    Liu, B.
    Mohiuddin, M. M.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (994): : 874 - 881
  • [29] Development of Colli-DTRT: A Non-Coplanar Intensity Modulated Arc Therapy Technique with Dynamic Collimator Rotation
    Bertholet, J.
    Zhu, C.
    Mackeprang, P-H
    Loebner, H.
    Guyer, G.
    Volken, W.
    Elicin, O.
    Aebersold, D.
    Stampanoni, M.
    Mueller, S.
    Fix, M.
    Manser, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E508 - E508
  • [30] A dosimetric comparison of non-coplanar volumetric modulated arc therapy and non-coplanar fixed field intensity modulated radiation therapy in hippocampus-avoidance whole-brain radiation therapy with a simultaneous integrated boost for brain metastases
    Zeng, Huaqu
    Zhong, Minzhi
    Chen, Zongyou
    Tang, Shukui
    Wen, Zunbei
    FRONTIERS IN ONCOLOGY, 2025, 14