Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases

被引:0
|
作者
Ventura, Tiago [1 ,2 ,3 ]
Rocha, Humberto [3 ,4 ,5 ]
Ferreira, Brigida da Costa [3 ,6 ,7 ]
Dias, Joana [3 ,4 ,5 ]
Lopes, Maria do Carmo [2 ,3 ,7 ]
机构
[1] Univ Aveiro, Phys Dept, Aveiro, Portugal
[2] Portuguese Oncol Inst Coimbra Francisco Gentil, EPE, Med Phys Dept, Coimbra, Portugal
[3] Inst Syst Engn & Comp Coimbra, Coimbra, Portugal
[4] Univ Coimbra, Econ Fac, Coimbra, Portugal
[5] Ctr Business & Econ Res, Coimbra, Portugal
[6] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, Lisbon, Portugal
[7] Univ Aveiro, I3N Phys Dept, Aveiro, Portugal
关键词
Beam angle optimization; Non-coplanar; Arc trajectory; VMAT; PARTIAL BREAST IRRADIATION; RADIATION-THERAPY; ANGLE OPTIMIZATION; ORIENTATION OPTIMIZATION; SINGLE-ARC; IMRT; COUCH; SELECTION; COPLANAR; ROTATION;
D O I
10.1007/s13246-021-01061-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two methods for non-coplanar beam direction optimization, one for static beams and another for arc trajectories, were proposed for intracranial tumours. The results of the beam angle optimizations were compared with the beam directions used in the clinical plans. Ten meningioma cases already treated were selected for this retrospective planning study. Algorithms for non-coplanar beam angle optimization (BAO) and arc trajectory optimization (ATO) were used to generate the corresponding plans. A plan quality score, calculated by a graphical method for plan assessment and comparison, was used to guide the beam angle optimization process. For each patient, the clinical plans (CLIN), created with the static beam orientations used for treatment, and coplanar VMAT approximated plans (VMAT) were also generated. To make fair plan comparisons, all plan optimizations were performed in an automated multicriteria calculation engine and the dosimetric plan quality was assessed. BAO and ATO plans presented, on average, moderate global plan score improvements over VMAT and CLIN plans. Nevertheless, while BAO and CLIN plans assured a more efficient OARs sparing, the ATO and VMAT plans presented a higher coverage and conformity of the PTV. Globally, all plans presented high-quality dose distributions. No statistically significant quality differences were found, on average, between BAO, ATO and CLIN plans. However, automated plan solution optimizations (BAO or ATO) may improve plan generation efficiency and standardization. In some individual patients, plan quality improvements were achieved with ATO plans, demonstrating the possible benefits of this automated optimized delivery technique.
引用
收藏
页码:1273 / 1283
页数:11
相关论文
共 48 条
  • [1] Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases
    Tiago Ventura
    Humberto Rocha
    Brigida da Costa Ferreira
    Joana Dias
    Maria do Carmo Lopes
    Physical and Engineering Sciences in Medicine, 2021, 44 : 1273 - 1283
  • [2] Non-coplanar beam direction optimization for intensity-modulated radiotherapy
    Meedt, G
    Alber, M
    Nüsslin, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (18): : 2999 - 3019
  • [3] Dynamic intensity-modulated non-coplanar arc radiotherapy (INCA) for head and neck cancer
    Krayenbuehl, Jerome
    Davis, J. Bernard
    Ciernik, I. Frank
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 (02) : 151 - 157
  • [4] Dynamic intensity-modulated non-coplanar ARC radiotherapy (INCA) for head and neck cancer
    Davis, JB.
    Ciernik, IF.
    Krayenbuehl, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S369 - S369
  • [5] Dosimetric Comparison of Automated Non-Coplanar Volumetric-Modulated Arc Therapy and Intensity-Modulated Proton Therapy in Angiosarcoma of the Scalp
    Inui, S.
    Tomita, N.
    Takaoka, T.
    Ueda, Y.
    Ohira, S.
    Tsuchiya, T.
    Miyazaki, M.
    Nishio, T.
    Koizumi, M.
    Konishi, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E675 - E675
  • [6] Dosimetric Comparison of Coplanar Volumetric Modulated Arc Therapy and Non-coplanar Intensity Modulated Radiation Therapy for Pancreatic Cancer
    Badkul, R. K.
    Kile, L.
    Saleh, H.
    Chen, A. M.
    Lominska, C. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E635 - E636
  • [7] Intensity-modulated radiotherapy for cancer in the cranial base region -: CoPlanar versus non-coplanar irradiation
    Eich, HT
    Hero, B
    Micke, O
    Skripnitchenko, R
    Seegenschmiedt, MH
    Berthod, F
    Müller, RP
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 12 - 12
  • [8] Comparison of Coplanar and Non-Coplanar Intensity Modulated Arc Techniques for Treatment of Intracranial Multi-Focal Stereotactic Radiosurgery
    Wang, Z.
    Kirkpatrick, J.
    Chang, Z.
    Cai, J.
    Zhuang, T.
    Yin, F.
    MEDICAL PHYSICS, 2010, 37 (06) : 3309 - +
  • [9] Radiotherapy for unresectable sinonasal cancers: Dosimetric comparison of intensity modulated radiation therapy with coplanar and non-coplanar volumetric modulated arc therapy
    Orlandi, Ester
    Giandini, Tommaso
    Iannacone, Eva
    De Ponti, Elena
    Carrara, Mauro
    Mongioj, Valeria
    Stucchi, Claudio
    Tana, Silvia
    Bossi, Paolo
    Licitra, Lisa
    Fallai, Carlo
    Pignoli, Emanuele
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 260 - 266
  • [10] An Optimization Approach for Noncoplanar Intensity-Modulated Arc Therapy Trajectories
    Rocha, Humberto
    Dias, Joana
    Ventura, Tiago
    Ferreira, Brigida
    Lopes, Maria do Carmo
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2019, PT III: 19TH INTERNATIONAL CONFERENCE, SAINT PETERSBURG, RUSSIA, JULY 1-4, 2019, PROCEEDINGS, PART III, 2019, 11621 : 199 - 214