Work loss in double-inlet pulse tube refrigerators

被引:3
|
作者
Zhu, SW [1 ]
Kawano, S [1 ]
Nogawa, M [1 ]
Inoue, T [1 ]
机构
[1] Aisin Seiki Co Ltd, Dev Dept 2, Corp R&D Sector, Aichi 4488650, Japan
关键词
cryocooler; pulse tube refrigerator; double-inlet; work loss;
D O I
10.1016/S0011-2275(98)00065-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analytic equation of the mass flow rate through the bypass of double-inlet pulse tube refrigerators was obtained by an analysis of the pressure drop in the regenerator. The work loss through the bypass is discussed based on this equation. The work toss decreases with the increase of the void volume ratio of the regenerator over the pulse tube, decreases with the increases in temperature ratio of the room temperature over the refrigeration temperature, and increases with the increase in 'double-inlet factor' which is introduced in this paper. The work loss ratio at 80K with an ideal double-inlet is about 50, 30, 20 and 10% when the void volume ratio of the regenerator over the pulse tube is 0.5, 1.0, 2.0, and 4.0, respectively. The analytic results were compared with numerical results. A good agreement between them was achieved. (C) 1998 Published by Elsevier Science Ltd. Ail rights reserved.
引用
收藏
页码:803 / 807
页数:5
相关论文
共 50 条
  • [21] Study on a single-stage pulse tube with two-valve double-inlet configuration
    Gan, Zhi-Hua
    Liu, Hua-Zhao
    Qiu, Li-Min
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2006, 27 (01): : 23 - 25
  • [22] Control of DC gas flow in a single-stage double-inlet pulse tube cooler
    Univ of Giessen, Giessen, Germany
    Cryogenics, 8 (843-847):
  • [23] Single stage double-inlet pulse tube refrigerator with integral thermo-electric cooler
    R, Karunanithi
    Jacob, S.
    Kasthurirengan, S.
    Nadig, Durgesh
    Behera, Upendra
    Tamizhanban, K.
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 245 - 248
  • [24] Visualization of DC gas flows in a double-inlet pulse tube refrigerator with a second orifice valve
    Shiraishi, M
    Takamatsu, K
    Murakami, M
    Nakano, A
    Iida, T
    Hozumi, Y
    CRYOCOOLERS 11, 2001, : 371 - 379
  • [25] Control of DC gas flow in a single-stage double-inlet pulse tube cooler
    Wang, C
    Thummes, G
    Heiden, C
    CRYOGENICS, 1998, 38 (08) : 843 - 847
  • [26] Impact of Varying Load Conditions and Cooling Energy Comparison of a Double-Inlet Pulse Tube Refrigerator
    Arslan, Muhammad
    Farooq, Muhammad
    Naqvi, Muhamamd
    Sultan, Umair
    Tahir, Zia-ur-Rehman
    Nawaz, Saad
    Waheed, Nazim
    Naqvi, Salman Raza
    Ali, Qasim
    Tariq, M. Suleman
    Chaudhry, Ijaz Ahmad
    Anderson, John M.
    Anukam, Anthony
    PROCESSES, 2020, 8 (03)
  • [27] Temperature oscillations of working gas inside a basic, an orifice and a double inlet pulse tube refrigerators
    Seo, K
    Shiraishi, M
    Murakami, M
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1395 - 1402
  • [28] Hot end loss at pulse tube refrigerators
    Gerster, J
    Thurk, M
    Reissig, L
    Seidel, P
    CRYOGENICS, 1998, 38 (06) : 679 - 682
  • [29] Miniature double-inlet pulse tube cryocooler: Design by thermoacoustic theory compared with preliminary experimental results
    Xiao, JH
    Yang, JH
    Tao, ZD
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1435 - 1441
  • [30] Miniature Double-Inlet Pulse Tube Cryocooler: Design By Thermoacoustic Theory Compared With Preliminary Experimental Results
    Xiao, J. H.
    Yang, J. H.
    Tao, Z. D.
    Advances in Cryogenic Engineering, (41/B):