Work loss in double-inlet pulse tube refrigerators

被引:3
|
作者
Zhu, SW [1 ]
Kawano, S [1 ]
Nogawa, M [1 ]
Inoue, T [1 ]
机构
[1] Aisin Seiki Co Ltd, Dev Dept 2, Corp R&D Sector, Aichi 4488650, Japan
关键词
cryocooler; pulse tube refrigerator; double-inlet; work loss;
D O I
10.1016/S0011-2275(98)00065-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analytic equation of the mass flow rate through the bypass of double-inlet pulse tube refrigerators was obtained by an analysis of the pressure drop in the regenerator. The work loss through the bypass is discussed based on this equation. The work toss decreases with the increase of the void volume ratio of the regenerator over the pulse tube, decreases with the increases in temperature ratio of the room temperature over the refrigeration temperature, and increases with the increase in 'double-inlet factor' which is introduced in this paper. The work loss ratio at 80K with an ideal double-inlet is about 50, 30, 20 and 10% when the void volume ratio of the regenerator over the pulse tube is 0.5, 1.0, 2.0, and 4.0, respectively. The analytic results were compared with numerical results. A good agreement between them was achieved. (C) 1998 Published by Elsevier Science Ltd. Ail rights reserved.
引用
收藏
页码:803 / 807
页数:5
相关论文
共 50 条
  • [11] Impact of Gedeon streaming on the efficiency of a double-inlet pulse tube refrigerator
    Tang, Ke
    Feng, Ye
    Jin, Tao
    Jin, Shenghan
    Yang, Rui
    APPLIED THERMAL ENGINEERING, 2017, 111 : 445 - 454
  • [12] THEORETICAL AND EXPERIMENTAL STUDIES OF A DOUBLE-INLET REVERSIBLE PULSE TUBE REFRIGERATOR
    WANG, C
    WU, PY
    CHEN, ZQ
    CRYOGENICS, 1993, 33 (06) : 648 - 652
  • [13] An adiabatic model for a two-stage double-inlet pulse tube refrigerator
    Shafi, K. A.
    Rasheed, K. K. A.
    George, J. M.
    Sajid, N. K. M.
    Kasthurirengan, S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (07) : 1247 - 1252
  • [14] Simultaneous Analytical Solution of the Complete System of Double-Inlet Pulse Tube Refrigerator
    Ghahremani, A. R.
    Saidi, M. H.
    Ebrahimian, M.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2012, 26 (02) : 337 - 344
  • [15] Two-stage double-inlet pulse tube refrigerator down to 10 K
    Wild, S
    Oellrich, LR
    Hofmann, A
    CRYOCOOLERS 9, 1997, : 255 - 260
  • [16] Thermodynamical aspects of double-inlet pulse tubes
    de Waele, ATAM
    Steijaert, PP
    Koning, JJ
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 55 - 58
  • [17] Visualization study of the local flow field in an orifice and double-inlet pulse tube refrigerator
    Shiraishi, M
    Nakamura, N
    Takamatsu, K
    Murakami, M
    Nakano, A
    CRYOCOOLERS 10, 1999, : 329 - 336
  • [18] Visualization of oscillating flow in a double-inlet pulse tube refrigerator with a diaphragm inserted in a bypass-tube
    Shiraishi, Masao
    Murakami, Masahide
    CRYOGENICS, 2012, 52 (7-9) : 410 - 415
  • [19] Investigation of an innovative method for DC flow suppression of double-inlet pulse tube coolers
    Hu, J. Y.
    Luo, E. C.
    Wu, Z. H.
    Dai, W.
    Zhu, S. L.
    CRYOGENICS, 2007, 47 (5-6) : 287 - 291
  • [20] Analysis of DC gas flow in GM type double inlet pulse tube refrigerators
    Zhu, Shaowei
    Nogawa, Masafumi
    Inoue, Tatsuo
    CRYOGENICS, 2009, 49 (02) : 66 - 71