A Study on Performance Evaluation of Magnetic Dental Attachments

被引:3
|
作者
Kang, Seen-Young [1 ]
Yu, Ji-Min [1 ]
Kim, Hyoung-Sik [1 ]
Park, Ki-Sook [1 ]
Lee, Seung-Youl [1 ]
机构
[1] Natl Inst Food & Drug Safety Evaluat, Med Device Res Div, 187 Osongsaengmyeong 2 Ro, Cheongju 28159, Chungcheongbuk, South Korea
关键词
magnetic dental attachment; ISO; 13017; retentive force; clinical environment; RETENTIVE FORCE; IN-VITRO; STUD ATTACHMENTS; IMPLANT; OVERDENTURES;
D O I
10.4283/JMAG.2019.24.4.733
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study measures retentive force as function of the diameter, the cross-head speed, and the number of detachments of dental magnetic attachments in a clinical environment, and analyzes the validity of the international standard method for testing them. In this study, tests 1, 2, and 3 were used to measure the retentive force as a function of the contact area of the magnetic attachment, and tests 2 and 4 as a function of the cross-head speed. Test 2 and 5 compared function of the retentive force as a function of repeated detachments Results showed that the retentive force increases as the sample surface increases, and decreases as the cross head speed increases. Additionally, after 1500 detachment cycles, the retentive force increased. Finally, the international standard test method was validated, because an objective method for testing magnetic attachments in clinical environment could not be found.
引用
收藏
页码:733 / 738
页数:6
相关论文
共 50 条
  • [41] Evaluation of welded attachments on pipe and elbows
    Wais, E.A.
    Rodabaugh, E.C.
    Rawls, G.B.
    Welding Research Council Bulletin, 2000, (448): : 19 - 40
  • [42] Study of the performance in simulated use of extracoronal attachments tip stud (Microflx - Rod)
    Rivaldo, EG
    Bonachela, WC
    Mezzomo, E
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B133 - B133
  • [43] Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study
    Nagy, Ursina
    Guedat, Christophe
    Giannopoulou, Catherine
    Schimmel, Martin
    Mueller, Frauke
    Srinivasan, Murali
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2019, 5 (05): : 476 - 484
  • [44] BREAKAWAY FORCES OF DYNA CHAIRSIDE MAGNETIC ATTACHMENTS
    PLOOIJ, J
    JONKMAN, REG
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 622 - 622
  • [45] General remarks concerning magnetic attachments in dentistry
    Tanaka, Y
    Nakamura, Y
    Hoshiai, K
    PROCEEDINGS OF THE JAPAN ACADEMY SERIES B-PHYSICAL AND BIOLOGICAL SCIENCES, 2002, 78 (05): : 97 - 105
  • [46] Five-year multicenter study of magnetic attachments used for natural overdenture abutments
    Gonda, T.
    Yang, T. C.
    Maeda, Y.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (04) : 258 - 262
  • [47] INFLUENCE OF REPEATED INSERTION-REMOVAL CYCLES ON THE FORCE AND MAGNETIC FLUX LEAKAGE OF MAGNETIC ATTACHMENTS: AN IN VITRO STUDY
    Hao, Zhichao
    Chao, Yonglie
    Meng, Yukun
    Yin, Hongmin
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02): : 235 - 240
  • [48] FEM Analysis of Dental Implant-Abutment Interface Overdenture Components and Parametric Evaluation of Equator® and Locator® Prosthodontics Attachments
    Cicciu, Marco
    Cervino, Gabriele
    Milone, Dario
    Risitano, Giacomo
    MATERIALS, 2019, 12 (04)
  • [49] Finite Element Analysis of Stress Distributions for Mandibular Dental Implant-Supported Overdentures with Magnetic Attachments in Osteoporotic and Normal Bone
    Hu, Fengling
    Zhang, Limin
    Zhang, Jianguo
    Zheng, Yicai
    Li, Yuan
    Zhang, Xiaoying
    Song, Liang
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (01) : 49 - 58
  • [50] Use of a dental surveyor to ensure optimal seating of implant overdenture attachments
    Loney, Robert W.
    Lee, Chris J.
    Michaud, Pierre-Luc
    Cook, Tanya J. A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03): : 381 - 383