High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model

被引:8
|
作者
Duprez, Frederic [1 ,5 ]
de Terwangne, C. [2 ]
Bellemans, V. [1 ]
Poncin, W. [3 ]
Reychler, G. [3 ]
Sorgente, A. [4 ]
Cuvelier, G. [5 ]
Mashayekhi, S. [1 ]
Wittebole, X. [6 ]
机构
[1] Ctr Hosp Epicura, Dept Intens Care, Hornu, Belgium
[2] Clin Univ St Luc, Dept Geriatr Med, Brussels, Belgium
[3] Catholic Univ Louvain, Dept Internal Med, Brussels, Belgium
[4] Ctr Hosp Epicura, Dept Cardiol, Hornu, Belgium
[5] Condorcet Sch, Lab Resp Physiol, Tournai, Belgium
[6] UCLouvain, Clin Univ St Luc, Dept Intens Care, Brussels, Belgium
关键词
Oxygenation through High Flow Delivery Systems; HFO; HFNC; Inspiratory flow; Minute ventilation; Effective inspired oxygen fraction; Double trunk mask; PRESSURE;
D O I
10.1007/s10877-021-00784-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Oxygenation through High Flow Delivery Systems (HFO) is described as capable of delivering accurate F-i(O2). Meanwhile, peak inspiratory flow <(V) over dot>(I)) of patients with acute hypoxemic respiratory failure can reach up to 120 L/min, largely exceeding HFO flow. Currently, very few data on the reliability of HFO devices at these high <(V) over dot>(I) are available. We sought to evaluate factors affecting oxygenation while using HFO systems at high <(V) over dot>(I) in a bench study. Spontaneous breathing was generated with a mechanical test lung connected to a mechanical ventilator Servo-i (R), set to volume control mode. Gas flow from a HFO device was delivered to the test lung. The influence on effective inspired oxygen fraction of three parameters (F-i(O2) 0.6, 0.8, and 1, <(V) over dot>(I) from 28 to 98.1 L/min, and HFO Gas Flows from 40 to 60 L/min) were analyzed and are reported. The present bench study demonstrates that during HFO treatment, measured F-i(O2) in the lung does not equal set F-i(O2) on the device. The substance of this variation (Delta F-i(O2)) is tightly correlated to <(V) over dot>(I) (Pearson's coefficient of 0.94, p-value< 0.001). Additionally, set F-i(O2) and Flow at HFO device appear to significatively affect Delta F-i(O2) as well (p-values < 0.001, adjusted to <(V) over dot>(I)). The result of multivariate linear regression indicates predictors (<(V) over dot>(I), Flow and set F-i(O2)) to explain 92% of the variance of delta F-i(O2) through K-Fold Cross Validation. Moreover, adjunction of a dead space in the breathing circuit significantly decreased Delta F-i(O2) (p <0.01). The present bench study did expose a weakness of HFO devices in reliability of delivering accurate F-I(O2) at high <(V) over dot>(I) as well as, to a lesser extent, at <(V) over dot>(I) below equivalent set HFO Flows. Moreover, set HFO flow and set F-I(O2) did influence the variability of effective inspired oxygen fraction. The adjunction of a dead space in the experimental set-up significantly amended this variability and should thus be further studied in order to improve success rate of HFO therapy.
引用
收藏
页码:1441 / 1448
页数:8
相关论文
共 50 条
  • [31] High-Flow Nasal Cannula in a Mixed Adult ICU
    Gaunt, Kristina A.
    Spilman, Sarah K.
    Halub, Meghan E.
    Jackson, Julie A.
    Lamb, Keith D.
    Sahr, Sheryl M.
    RESPIRATORY CARE, 2015, 60 (10) : 1383 - 1389
  • [32] CPAP and High-Flow Nasal Cannula Oxygen in Bronchiolitis
    Sinha, Ian P.
    McBride, Antonia K. S.
    Smith, Rachel
    Fernandes, Ricardo M.
    CHEST, 2015, 148 (03) : 810 - 823
  • [33] High-Flow Nasal Cannula Oxygen in Respiratory Failure
    Shein, Steven L.
    NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (14): : 1374 - 1374
  • [34] Humidity and Inspired Oxygen Concentration During High-Flow Nasal Cannula Therapy in Neonatal and Infant Lung Models
    Chikata, Yusuke
    Ohnishi, Saki
    Nishimura, Masaji
    RESPIRATORY CARE, 2017, 62 (05) : 532 - 537
  • [35] Severe pulmonary embolism managed with high-flow nasal cannula oxygen therapy
    Messika, Jonathan
    Goutorbe, Philippe
    Hajage, David
    Ricard, Jean-Damien
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2017, 24 (03) : 230 - 232
  • [36] Efficacy of High-Flow Nasal Cannula Oxygen Therapy in Patients with Mild Hypercapnia
    Su, Lingling
    Zhao, Qinyu
    Liu, Taotao
    Xu, Yujun
    Li, Weichun
    Zhang, Aiping
    LUNG, 2021, 199 (05) : 447 - 456
  • [37] OUTCOME OF HIGH-FLOW NASAL CANNULA OXYGEN THERAPY IN PATIENTS DURING FLEXIBLE BRONCHOSCOPY COMPARE WITH CONVENTIONAL NASAL OXYGEN CANNULA
    Vangtal, P.
    RESPIROLOGY, 2016, 21 : 155 - 155
  • [38] High-Flow Nasal Cannula Oxygen Therapy: Innovative Strategies for Traditional Procedures
    Roca, Oriol
    Masclans, Joan R.
    CRITICAL CARE MEDICINE, 2015, 43 (03) : 707 - 708
  • [39] A Survey of Feeding Practices During High-Flow Nasal Cannula Oxygen Therapy
    Charlton, Megan E.
    Peterson, Sarah J.
    LaGorio, Lisa A.
    Mirza, Sara H.
    Scott, J. Brady
    RESPIRATORY CARE, 2023, 68 (09) : 1229 - 1236
  • [40] High-Flow Nasal Cannula Oxygen Therapy During Hypoxemic Respiratory Failure
    El-Khatib, Mohamad F.
    RESPIRATORY CARE, 2012, 57 (10) : 1696 - 1698