High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model

被引:8
|
作者
Duprez, Frederic [1 ,5 ]
de Terwangne, C. [2 ]
Bellemans, V. [1 ]
Poncin, W. [3 ]
Reychler, G. [3 ]
Sorgente, A. [4 ]
Cuvelier, G. [5 ]
Mashayekhi, S. [1 ]
Wittebole, X. [6 ]
机构
[1] Ctr Hosp Epicura, Dept Intens Care, Hornu, Belgium
[2] Clin Univ St Luc, Dept Geriatr Med, Brussels, Belgium
[3] Catholic Univ Louvain, Dept Internal Med, Brussels, Belgium
[4] Ctr Hosp Epicura, Dept Cardiol, Hornu, Belgium
[5] Condorcet Sch, Lab Resp Physiol, Tournai, Belgium
[6] UCLouvain, Clin Univ St Luc, Dept Intens Care, Brussels, Belgium
关键词
Oxygenation through High Flow Delivery Systems; HFO; HFNC; Inspiratory flow; Minute ventilation; Effective inspired oxygen fraction; Double trunk mask; PRESSURE;
D O I
10.1007/s10877-021-00784-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Oxygenation through High Flow Delivery Systems (HFO) is described as capable of delivering accurate F-i(O2). Meanwhile, peak inspiratory flow <(V) over dot>(I)) of patients with acute hypoxemic respiratory failure can reach up to 120 L/min, largely exceeding HFO flow. Currently, very few data on the reliability of HFO devices at these high <(V) over dot>(I) are available. We sought to evaluate factors affecting oxygenation while using HFO systems at high <(V) over dot>(I) in a bench study. Spontaneous breathing was generated with a mechanical test lung connected to a mechanical ventilator Servo-i (R), set to volume control mode. Gas flow from a HFO device was delivered to the test lung. The influence on effective inspired oxygen fraction of three parameters (F-i(O2) 0.6, 0.8, and 1, <(V) over dot>(I) from 28 to 98.1 L/min, and HFO Gas Flows from 40 to 60 L/min) were analyzed and are reported. The present bench study demonstrates that during HFO treatment, measured F-i(O2) in the lung does not equal set F-i(O2) on the device. The substance of this variation (Delta F-i(O2)) is tightly correlated to <(V) over dot>(I) (Pearson's coefficient of 0.94, p-value< 0.001). Additionally, set F-i(O2) and Flow at HFO device appear to significatively affect Delta F-i(O2) as well (p-values < 0.001, adjusted to <(V) over dot>(I)). The result of multivariate linear regression indicates predictors (<(V) over dot>(I), Flow and set F-i(O2)) to explain 92% of the variance of delta F-i(O2) through K-Fold Cross Validation. Moreover, adjunction of a dead space in the breathing circuit significantly decreased Delta F-i(O2) (p <0.01). The present bench study did expose a weakness of HFO devices in reliability of delivering accurate F-I(O2) at high <(V) over dot>(I) as well as, to a lesser extent, at <(V) over dot>(I) below equivalent set HFO Flows. Moreover, set HFO flow and set F-I(O2) did influence the variability of effective inspired oxygen fraction. The adjunction of a dead space in the experimental set-up significantly amended this variability and should thus be further studied in order to improve success rate of HFO therapy.
引用
收藏
页码:1441 / 1448
页数:8
相关论文
共 50 条
  • [1] High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model
    Frédéric Duprez
    C. de Terwangne
    V. Bellemans
    W. Poncin
    G. Reychler
    A. Sorgente
    G. Cuvelier
    S. Mashayekhi
    X. Wittebole
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1441 - 1448
  • [2] Factors affecting FiO2 and PEEP during high-flow nasal cannula oxygen therapy: A bench study
    Sun, Yu-Han
    Dai, Bing
    Peng, Yun
    Tan, Wei
    Zhao, Hong-Wen
    CLINICAL RESPIRATORY JOURNAL, 2019, 13 (12): : 758 - 764
  • [3] Flow Field Analysis of Adult High-Flow Nasal Cannula Oxygen Therapy
    Xia, Jingen
    Chang, Jiaqi
    Liang, Jixiang
    Wang, Yixuan
    Wang, Na
    COMPLEXITY, 2021, 2021
  • [4] High-flow nasal cannula therapy for adult patients
    Zhang, Jian
    Lin, Ling
    Pan, Konghan
    Zhou, Jiancang
    Huang, Xiaoyin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (06) : 1200 - 1211
  • [5] High-Flow Nasal Cannula Oxygen Therapy Devices
    Nishimura, Masaji
    RESPIRATORY CARE, 2019, 64 (06) : 735 - 741
  • [6] High-flow nasal cannula oxygen therapy in adults
    Nishimura M.
    Journal of Intensive Care, 3 (1)
  • [7] Year in Review 2019: High-Flow Nasal Cannula Oxygen Therapy for Adult Subjects
    Li, Jie
    Jing, Guoqiang
    Scott, J. Brady
    RESPIRATORY CARE, 2020, 65 (04) : 545 - 557
  • [8] High-flow nasal cannula oxygen therapy for modified electroconvulsive therapy
    Karim, Habib M. R.
    Esquinas, Antonio M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (01) : 56 - 57
  • [9] Noise Exposure From High-Flow Nasal Cannula Oxygen Therapy: A Bench Study on Noise Reduction
    Kubo, Takamitsu
    Nakajima, Hiroaki
    Shimoda, Ryo
    Seo, Tatsuya
    Kanno, Yurie
    Kondo, Toshikazu
    Tamai, Sunao
    RESPIRATORY CARE, 2018, 63 (03) : 267 - 273
  • [10] High-Flow Oxygen Administration by Nasal Cannula for Adult and Perinatal Patients
    Ward, Jeffrey J.
    RESPIRATORY CARE, 2013, 58 (01) : 98 - 120