Anodized Edge-plane Pyrolytic Graphite for Electroanalysis of Pantoprazole in Tablet Dosage Forms and Human Urine Samples

被引:5
|
作者
Hadi, Mojtaba [1 ]
Ehsani, Ali [1 ]
机构
[1] Univ Qom, Dept Chem, Fac Sci, Qom, Iran
关键词
Edge-plane pyrolytic graphite; graphitic carbon-based electrodes; anodic activation; pantoprazole electroanalysis; nano-graphene; carbon nanotube; SPECTROPHOTOMETRIC DETERMINATION; ITOPRIDE HYDROCHLORIDE; RAMAN-SPECTROSCOPY; CARBON NANOTUBES; ELECTRODES; VALIDATION; SODIUM; OMEPRAZOLE; GRAPHENE; SPECTRA;
D O I
10.17159/0379-4350/2016/v69a10
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electroanalytical parameters of different graphitic carbon-based electrode materials were compared to select the best one for the pantoprazole electroanalysis. Such parameters include sensitivity, repeatability, residual background current, and signal-to-background current ratio of the analytical response and such electrodes include conventional carbon-based electrodes such as glassy carbon (GC), carbon paste, edge-plane pyrolytic graphite (EPPG), and basal-plane pyrolytic graphite electrodes and film-coated modified GC electrodes with graphitic carbon-based materials such as carbon nanotube, nanographene, carbon black and graphite powder. The EPPG electrode, after applying a simple electrochemical anodization, showed more acceptable analytical performances compared with the other electrodes. Raman spectroscopy was employed to study the surface structural changes that occurred dring the anodic activation. Calibration plot with a good linearity was obtained in the concentration range of 0.2-25 and 0.02-8.5 mu M, and the detection limit was estimated to be 0.055 and 0.0041 mu M using cyclic voltammetry and differential pulse voltammetry techniques, respectively. Finally, the electrochemically activated EPPG electrode was used successfully for the determination of pantoprazole in tablet dosage forms and human urine samples with satisfactory results.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 44 条
  • [31] Electrochemical determination of guaifenesin in a pharmaceutical formulation and human urine based on an anodized nanocrystalline graphite-like pyrolytic carbon film electrode
    Hadi, M.
    ANALYTICAL METHODS, 2015, 7 (20) : 8778 - 8785
  • [32] Electrochemical Oxidation of Acetyl Salicylic Acid and its voltammetric sensing in real samples at a sensitive edge plane Pyrolytic Graphite Electrode modified with Graphene
    Kruanetr, Senee
    Pollard, Pat
    Fernandez, Carlos
    Prabhu, Radhakrishna
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (10): : 5699 - 5711
  • [33] Insights into the electro-oxidation of hydrazine at single-walled carbon-nanotube-modified edge-plane pyrolytic graphite electrodes electro-decorated with metal and metal oxide films
    Abolanle S. Adekunle
    Kenneth I. Ozoemena
    Journal of Solid State Electrochemistry, 2008, 12 : 1325 - 1336
  • [34] Insights into the electro-oxidation of hydrazine at single-walled carbon-nanotube-modified edge-plane pyrolytic graphite electrodes electro-decorated with metal and metal oxide films
    Adekunle, Abolanle S.
    Ozoemena, Kenneth I.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (10) : 1325 - 1336
  • [35] Comparative study of boron-doped diamond, basal-plane pyrolytic graphite, and graphite flake paste electrodes for the voltammetric determination of rivaroxaban and dabigatran etexilate in pharmaceuticals and urine samples
    Festinger, Natalia
    Smarzewska, Sylwia
    Ciesielski, Witold
    DIAMOND AND RELATED MATERIALS, 2021, 118
  • [36] Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids
    Goyal, Rajendra N.
    Gupta, Vinod K.
    Chatterjee, Sanghamitra
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (06): : 1649 - 1654
  • [37] Osteryoung square wave voltammetric determination of phenazopyridine hydrochloride in human urine and tablet dosage forms based on electrochemical reduction at carbon paste electrode
    Citak, Meryem
    Yilmaz, Selahattin
    Dilgin, Yusuf
    Tuerker, Guelen
    Yagmur, Sultan
    Erdugan, Hueseyin
    Erdugan, Necla
    CURRENT PHARMACEUTICAL ANALYSIS, 2007, 3 (02) : 141 - 145
  • [38] Development of an electroanalytical method to control quality in fish samples based on an edge plane pyrolytic graphite electrode. Simultaneous determination of hypoxanthine, xanthine and uric acid
    Dario Pierini, Gaston
    Noel Robledo, Sebastian
    Alicia Zon, Maria
    Susana Di Nezio, Maria
    Marcelo Granero, Adrian
    Fernandez, Hector
    MICROCHEMICAL JOURNAL, 2018, 138 : 58 - 64
  • [39] Comparative Study of Basal-Plane Pyrolytic Graphite, Boron-Doped Diamond, and Amorphous Carbon Nitride Electrodes for the Voltammetric Determination of Furosemide in Pharmaceutical and Urine Samples
    Medeiros, Roberta A.
    Baccarin, Marina
    Fatibello-Filho, Orlando
    Rocha-Filho, Romeu C.
    Deslouis, Claude
    Debiemme-Chouvy, Catherine
    ELECTROCHIMICA ACTA, 2016, 197 : 179 - 185
  • [40] Utility of NBD-Cl as an electrophilic reagent for the determination of the two antihypertensive drugs hydrochlorothiazide and minoxidil in dosage forms and human urine samples
    Elmansi, Heba
    Belal, Fathalla
    Hosny, Mervat M.
    EL-Abassy, Omar M.
    CHEMICAL PAPERS, 2021, 75 (05): : 1925 - 1935