Anodized Edge-plane Pyrolytic Graphite for Electroanalysis of Pantoprazole in Tablet Dosage Forms and Human Urine Samples

被引:5
|
作者
Hadi, Mojtaba [1 ]
Ehsani, Ali [1 ]
机构
[1] Univ Qom, Dept Chem, Fac Sci, Qom, Iran
关键词
Edge-plane pyrolytic graphite; graphitic carbon-based electrodes; anodic activation; pantoprazole electroanalysis; nano-graphene; carbon nanotube; SPECTROPHOTOMETRIC DETERMINATION; ITOPRIDE HYDROCHLORIDE; RAMAN-SPECTROSCOPY; CARBON NANOTUBES; ELECTRODES; VALIDATION; SODIUM; OMEPRAZOLE; GRAPHENE; SPECTRA;
D O I
10.17159/0379-4350/2016/v69a10
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electroanalytical parameters of different graphitic carbon-based electrode materials were compared to select the best one for the pantoprazole electroanalysis. Such parameters include sensitivity, repeatability, residual background current, and signal-to-background current ratio of the analytical response and such electrodes include conventional carbon-based electrodes such as glassy carbon (GC), carbon paste, edge-plane pyrolytic graphite (EPPG), and basal-plane pyrolytic graphite electrodes and film-coated modified GC electrodes with graphitic carbon-based materials such as carbon nanotube, nanographene, carbon black and graphite powder. The EPPG electrode, after applying a simple electrochemical anodization, showed more acceptable analytical performances compared with the other electrodes. Raman spectroscopy was employed to study the surface structural changes that occurred dring the anodic activation. Calibration plot with a good linearity was obtained in the concentration range of 0.2-25 and 0.02-8.5 mu M, and the detection limit was estimated to be 0.055 and 0.0041 mu M using cyclic voltammetry and differential pulse voltammetry techniques, respectively. Finally, the electrochemically activated EPPG electrode was used successfully for the determination of pantoprazole in tablet dosage forms and human urine samples with satisfactory results.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 44 条
  • [11] Electrochemical Oxidation of Adenine: A Mixed Adsorption and Diffusion Response on an Edge-Plane Pyrolytic Graphite Electrode
    Goncalves, Luis M.
    Batchelor-McAuley, Christopher
    Barros, Aquiles A.
    Compton, Richard G.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (33): : 14213 - 14219
  • [12] A comparison of Edge-plane and Basal-plane Pyrolytic Graphite Electrodes Towards Sensitive Determination of the Fungicide Mandipropamid
    Festinger, Natalia
    Lemiesz, Adrianna
    Skowron, Ewelina
    Smarzewska, Sylwia
    Ciesielski, Witold
    ELECTROANALYSIS, 2021, 33 (04) : 854 - 863
  • [13] Electrochemical behaviors of alizarin and Cr(VI)-Alizarin complex adsorbed on edge-plane pyrolytic graphite electrode
    Silva Furtado, Nielson Jose
    de Oliveira Farias, Emanuel Airton
    Eiras, Carla
    Magalhaes, Janildo Lopes
    Silva, Janiciara Botelho
    SURFACES AND INTERFACES, 2019, 14 : 238 - 244
  • [14] Gas sensing using edge-plane pyrolytic-graphite electrodes: electrochemical reduction of chlorine
    Eleanor R. Lowe
    Craig E. Banks
    Richard G. Compton
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1169 - 1174
  • [15] Improved Electrochemical Detection of Purine Nucleobases at Mechanically Roughened Edge-Plane Pyrolytic Graphite Electrode
    Hason, Stanislav
    Fojt, Lukas
    Sebest, Peter
    Fojta, Miroslav
    ELECTROANALYSIS, 2009, 21 (3-5) : 666 - 670
  • [16] Electrochemical investigations of diclofenac at edge plane pyrolytic graphite electrode and its determination in human urine
    Goyal, Rajendra N.
    Chatterjee, Sanghamitra
    Agrawal, Bharati
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (02) : 743 - 748
  • [17] Electrochemistry of Levo-Thyroxin on Edge-Plane Pyrolytic Graphite Electrode: Application to Sensitive Analytical Determinations
    Khafaji, Mona
    Shahrokhian, Saeed
    Ghalkhani, Masoumeh
    ELECTROANALYSIS, 2011, 23 (08) : 1875 - 1880
  • [18] Simultaneous determination of epinephrine and norepinephrine in human blood plasma and urine samples using nanotubes modified edge plane pyrolytic graphite electrode
    Goyal, Rajendra N.
    Bishnoi, Sunita
    TALANTA, 2011, 84 (01) : 78 - 83
  • [19] Edge plane pyrolytic graphite as a sensing surface for the determination of fluvoxamine in urine samples of obsessive-compulsive disorder patients
    Bishnoi, Sunita
    Sharma, Ashutosh
    Singhal, Rahul
    Goyal, Rajendra N.
    BIOSENSORS & BIOELECTRONICS, 2020, 168 (168):
  • [20] Sensitive voltammetric determination of famotidine in human urine and tablet dosage forms using an ultra trace graphite electrode
    Yagmur, Sultan
    Yilmaz, Selehattin
    Saglikoglu, Gulsen
    Uslu, Bengi
    Sadikoglu, Murat
    Ozkan, Sibel A.
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2014, 79 (01) : 53 - 62