Microwave-assisted wet digestion with H2O2 at high temperature and pressure using single reaction chamber for elemental determination in milk powder by ICP-OES and ICP-MS

被引:54
|
作者
Muller, Edson I. [1 ]
Souza, Juliana P. [1 ]
Muller, Cristiano C. [1 ]
Muller, Aline L. H. [1 ]
Mello, Paola A. [1 ]
Bizzi, Cezar A. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
关键词
Hydrogen peroxide; Milk powder; Single reaction chamber; Microwave-assisted wet digestion; Elemental analysis; Trace elements; ACTIVE PHARMACEUTICAL INGREDIENTS; HYDROGEN-PEROXIDE; METALS DETERMINATION; TRACE-ELEMENTS; TOXIC ELEMENTS; SAMPLES; SPECTROMETRY; OXIDATION; DECOMPOSITION; FEASIBILITY;
D O I
10.1016/j.talanta.2016.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave (TM)) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500 mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918 mg L-1 of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 47 条
  • [41] Evaluation of a digestion procedure based on the use of diluted nitric acid solutions and H2O2 for the multielement determination of whole milk powder and bovine liver by ICP-based techniques
    Bizzi, Cezar A.
    Flores, Eder L. M.
    Nobrega, Joaquim A.
    Oliveira, Jussiane S. S.
    Schmidt, Lucas
    Mortari, Sergio R.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (02) : 332 - 338
  • [42] New Approaches in Sample Preparation and Precise Multielement Analysis of Crude Oils and Refined Petroleum Products Using Single-Reaction-Chamber Microwave Digestion and Triple-Quadrupole ICP-MS
    Casey, John F.
    Gao, Yongjun
    Yang, Weihang
    Thomas, Robert
    SPECTROSCOPY, 2016, 31 (10) : 11 - 22
  • [43] Optimization of H2O2 action in sewage-sludge microwave digestion using Δ pressure vs. temperature and pressure vs. time graphs
    Veschetti, E
    Maresca, D
    Cutilli, D
    Santarsiero, A
    Ottaviani, M
    MICROCHEMICAL JOURNAL, 2000, 67 (1-3) : 171 - 179
  • [44] Chelation-assisted electrothermal vaporization for the ICP-MS determination of trace rare earth impurities in high purity Pr6O11 and Er2O3
    Yin, Jun
    Hu, Bin
    Jiang, Zucheng
    ATOMIC SPECTROSCOPY, 2006, 27 (06) : 207 - 213
  • [45] Microwave-assisted dissolution of highly refractory dysprosium-titanate (Dy2TiO5) followed by chemical characterization for major and trace elements using ICP-MS, UV-visible spectroscopy and conventional methods
    Nagar, Brijlesh Kumar
    Kumari, Khushboo
    Deb, Sadhan Bijoy
    Saxena, Manoj Kumar
    Tomar, Bhupendra Singh
    RADIOCHIMICA ACTA, 2018, 106 (11) : 917 - 926
  • [46] HPLC combined with ICP-MS for the determination of trace amounts of rare earth impurities in high-purity La2O3 by using 2-ethylhexyl hydrogen-2-ethylhexylphosphonate resin as a stationary phase
    Shuai Qin
    Zucheng Jiang
    Bin Hu
    Yongchao Qin
    Shenghong Hu
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 250 - 253
  • [47] HPLC combined with ICP-MS for the determination of trace amounts of rare earth impurities in high-purity La2O3 by using 2-ethylhexyl hydrogen-2-ethylhexylphosphonate resin as a stationary phase
    Qin, S
    Jiang, ZC
    Hu, B
    Qin, YC
    Hu, SS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (03): : 250 - 253