Microwave-assisted wet digestion with H2O2 at high temperature and pressure using single reaction chamber for elemental determination in milk powder by ICP-OES and ICP-MS

被引:54
|
作者
Muller, Edson I. [1 ]
Souza, Juliana P. [1 ]
Muller, Cristiano C. [1 ]
Muller, Aline L. H. [1 ]
Mello, Paola A. [1 ]
Bizzi, Cezar A. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
关键词
Hydrogen peroxide; Milk powder; Single reaction chamber; Microwave-assisted wet digestion; Elemental analysis; Trace elements; ACTIVE PHARMACEUTICAL INGREDIENTS; HYDROGEN-PEROXIDE; METALS DETERMINATION; TRACE-ELEMENTS; TOXIC ELEMENTS; SAMPLES; SPECTROMETRY; OXIDATION; DECOMPOSITION; FEASIBILITY;
D O I
10.1016/j.talanta.2016.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave (TM)) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500 mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918 mg L-1 of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 47 条
  • [31] Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion
    Heilmann, J
    Boulyga, SF
    Heumann, KG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (02) : 190 - 197
  • [32] Rapid and accurate determination of chlorine isotopic ratios with ICP-MS/MS using O2 reaction gas
    Schlieder, Tyler D.
    Rocco, Nicole D.
    di Vacri, Maria Laura
    Arnquist, Isaac J.
    Bottenus, Danny
    Huber, Zachary
    Mcnamara, Bruce
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (10) : 2502 - 2507
  • [33] Microwave-assisted digestion using dilute nitric acid solution and investigation of calibration strategies for determination of As, Cd, Hg and Pb in dietary supplements using ICP-MS
    Pinheiro, Fernanda Costa
    Babos, Diego Victor
    Barros, Ariane Isis
    Pereira-Filho, Edenir Rodrigues
    Nobrega, Joaquim Araujo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 471 - 478
  • [34] Determination of toxic elements in yerba mate by ICP-MS after diluted acid digestion under O2 pressure
    Pardinho, Renan B.
    Dalla Vecchia, Paula
    Mendes, Ana L. G.
    Bizzi, Cezar A.
    Mello, Paola A.
    Duarte, Fabio A.
    Flores, Erico M. M.
    FOOD CHEMISTRY, 2018, 263 : 37 - 41
  • [35] Determination of Heavy Metals in Botanicals and Dietary Supplements by Using Collision/Reaction Cell ICP-MS: Comparison of Microwave Digestions Assisted by Six Types of Digestion Mixtures
    Avula, B.
    Wang, Y. H.
    Smillie, T. J.
    Khan, I. A.
    PLANTA MEDICA, 2009, 75 (04) : 438 - 438
  • [36] Improved determination of technologically critical elements in sediment digests by ICP-MS/MS using N2O as a reaction gas
    Pröfrock, Daniel (daniel.proefrock@hzg.de), 1600, Royal Society of Chemistry (36):
  • [37] Microwave-assisted carbofuran degradation in the presence of GAC, ZVI and H2O2: Influence of reaction temperature and pH
    Remya, Neelancherry
    Lin, Jih-Gaw
    SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 76 (03) : 244 - 252
  • [38] Improved determination of technologically critical elements in sediment digests by ICP-MS/MS using N2O as a reaction gas
    Klein, Ole
    Zimmermann, Tristan
    Proefrock, Daniel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (07) : 1524 - 1532
  • [39] A rapid microwave-assisted acid extraction method based on the use of diluted HNO3-H2O2 followed by ICP-MS analysis for simultaneous determination of trace elements in coal samples
    Mketo, Nomvano
    Nomngongo, Philiswa N.
    Ngila, J. Catherine
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (05) : 453 - 465