Numerical investigation on the factors influencing the temperature distribution of photovoltaic/thermal (PVT) evaporator/condenser for heat pump systems

被引:27
|
作者
Bisengimana, Emmanuel [1 ]
Zhou, Jinzhi [1 ]
Binama, Maxime [2 ]
Yuan, Yanping [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu, Sichuan, Peoples R China
[2] Hohai Univ, Coll Water Conservancy & Hydropower Engn, Nanjing 210098, Peoples R China
基金
中国博士后科学基金;
关键词
Heat pump; PVT evaporator; Condenser; Efficiency factor; Temperature distribution; PERFORMANCE ANALYSIS; WATER-HEATER; SIMULATION; OPTIMIZATION; DESIGN;
D O I
10.1016/j.renene.2022.05.154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to a high solar energy utilizing efficiency, Direct-expansion Solar-Assisted Heat Pump (DX SAHP) system has been a research hotspot for many years, especially for the system using PV/T module as the evaporator. The heat transfer throughout the PVT evaporator is an important factor for either electrical or thermal performance. We have developed and analyzed numerically the temperature distribution of a multi-source PVT heat exchanger of serpentine shape to fit a function as evaporator/condenser for Direct-expansion Photovoltaic/Thermal-Heat Pump (DX PVTHP) system. The suitability of the developed model was based on the calculated results of the efficiency factor and simulated results of temperatures of heat exchanger and working fluid as well the working fluid pressure drop. During the numerical simulations, we have considered different temperature influencing factors such as the refrigerant and refrigerant flow rate, spacing between the adjacent tubes of the heat exchanger, backside convection and radiation effect and finned heat exchanger. Simulated results showed that the serpentine PVT heat exchanger with fins and small space between tubes (62.5 mm) at 0.02 kg/s flow rate could achieve better results in terms of uniform temperature distribution, smaller fluid pressure drop (0.078 bar) and the highest efficiency factor (0.9873) which make it recommended as the best option for suitable evaporator/ condenser. The average PV temperature reached by cooled and uncooled PVT evaporator at 0.02 kg/s flow rate was 47.81 & DEG;C and 71.11 & DEG;C, respectively. It was 40.99 & DEG;C and 37.07 & DEG;C at the flow rate of 0.035 kg/s and 0.05 kg/s, respectively, and 44.44 & DEG;C for PVT evaporator with smaller space between tubes at 0.02 kg/s. The average PV temperature reached by the PVT evaporator with fins was 40.734 & DEG;C at the flow rate of 0.02 kg/s while it was 53.956 & DEG;C when the unit is insulated. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:885 / 901
页数:17
相关论文
共 50 条
  • [41] Performance of direct expansion photovoltaic-thermal evaporator assisted compression heat pump water heaters using a zeotropic mixture
    Yogaraja, J.
    Mohanraj, M.
    Manikandan, J.
    Muthusamy, P.
    SOLAR ENERGY, 2024, 271
  • [42] Numerical analysis and optimization study of photovoltaic/thermal-air source evaporator based on micro heat pipe arrays
    Liu, Yiyang
    Quan, Zhenhua
    Du, Boyao
    Bai, Ze
    Zhao, Yaohua
    Wang, Hongyan
    SOLAR ENERGY, 2024, 269
  • [43] Performance investigation on a concentrating photovoltaic thermal system integrated with spectral splitter and absorption heat pump
    Zhang, Luobin
    Hu, Yue
    Chu, Jiankang
    Xu, Cheng
    Yao, Yucheng
    Lv, Hui
    APPLIED THERMAL ENGINEERING, 2024, 237
  • [44] Analysis of key influencing factors for multi-mode solar heat pump systems
    Wang, Gang
    Yang, Yongqing
    Hu, Tao
    Yu, Wan
    Han, Xilian
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2022, 14 (05)
  • [45] Numerical Investigation of Amounts of Heat, Power and Temperature Distribution in IT-SOFC
    Bakal, Ahmet
    Kaya, Murat
    Mat, Mahmut D.
    HIGH TEMPERATURE EXPERIMENTAL TECHNIQUES AND MEASUREMENTS, 2013, 58 (03): : 115 - 129
  • [46] Numerical investigation of the effect of waste heat extracting location on temperature distribution
    Tie, Zhanxu
    Li, Haixia
    Guo, Xiaodian
    PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 361 - +
  • [47] Solar Assisted Heat Pump Water Heater Using Photovoltaic-Thermal Collector Evaporator and Its Building Energy Saving Performance
    Wang, Liguang
    Wang, Chao
    Zhao, Yang
    Zheng, Qiuling
    Chi, Yaodan
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2021, 16 (03) : 395 - 402
  • [48] Experimental and numerical investigation of a novel high-temperature heat pump for sensible and latent heat delivery
    Ramirez, Miguel
    Trebilcock-Kelly, Felipe
    Corrales-Ciganda, Jose L.
    Pay, Jorge
    Hassan, Abdelrahman H.
    APPLIED THERMAL ENGINEERING, 2024, 247
  • [49] Investigation on a direct-expansion solar-assisted heat pump with a novel hybrid compound parabolic concentrator/photovoltaic/fin evaporator
    Song, Zhiying
    Ji, Jie
    Cai, Jingyong
    Zhao, Bin
    Li, Zhaomeng
    APPLIED ENERGY, 2021, 299
  • [50] Model Validation and Performance Assessment of Unglazed Photovoltaic-Thermal Collectors with Heat Pump Systems
    Chhugani, Bharat
    Paerisch, Peter
    Kirchner, Maik
    Littwin, Matthias
    Lampe, Carsten
    Giovannetti, Federico
    PROCEEDINGS OF THE ISES EUROSUN 2020 CONFERENCE - 13TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2020, : 564 - 575