Numerical investigation on the factors influencing the temperature distribution of photovoltaic/thermal (PVT) evaporator/condenser for heat pump systems

被引:27
|
作者
Bisengimana, Emmanuel [1 ]
Zhou, Jinzhi [1 ]
Binama, Maxime [2 ]
Yuan, Yanping [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu, Sichuan, Peoples R China
[2] Hohai Univ, Coll Water Conservancy & Hydropower Engn, Nanjing 210098, Peoples R China
基金
中国博士后科学基金;
关键词
Heat pump; PVT evaporator; Condenser; Efficiency factor; Temperature distribution; PERFORMANCE ANALYSIS; WATER-HEATER; SIMULATION; OPTIMIZATION; DESIGN;
D O I
10.1016/j.renene.2022.05.154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to a high solar energy utilizing efficiency, Direct-expansion Solar-Assisted Heat Pump (DX SAHP) system has been a research hotspot for many years, especially for the system using PV/T module as the evaporator. The heat transfer throughout the PVT evaporator is an important factor for either electrical or thermal performance. We have developed and analyzed numerically the temperature distribution of a multi-source PVT heat exchanger of serpentine shape to fit a function as evaporator/condenser for Direct-expansion Photovoltaic/Thermal-Heat Pump (DX PVTHP) system. The suitability of the developed model was based on the calculated results of the efficiency factor and simulated results of temperatures of heat exchanger and working fluid as well the working fluid pressure drop. During the numerical simulations, we have considered different temperature influencing factors such as the refrigerant and refrigerant flow rate, spacing between the adjacent tubes of the heat exchanger, backside convection and radiation effect and finned heat exchanger. Simulated results showed that the serpentine PVT heat exchanger with fins and small space between tubes (62.5 mm) at 0.02 kg/s flow rate could achieve better results in terms of uniform temperature distribution, smaller fluid pressure drop (0.078 bar) and the highest efficiency factor (0.9873) which make it recommended as the best option for suitable evaporator/ condenser. The average PV temperature reached by cooled and uncooled PVT evaporator at 0.02 kg/s flow rate was 47.81 & DEG;C and 71.11 & DEG;C, respectively. It was 40.99 & DEG;C and 37.07 & DEG;C at the flow rate of 0.035 kg/s and 0.05 kg/s, respectively, and 44.44 & DEG;C for PVT evaporator with smaller space between tubes at 0.02 kg/s. The average PV temperature reached by the PVT evaporator with fins was 40.734 & DEG;C at the flow rate of 0.02 kg/s while it was 53.956 & DEG;C when the unit is insulated. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:885 / 901
页数:17
相关论文
共 50 条
  • [31] Performance and control of a CO2 dual source solar assisted heat pump with a photovoltaic-thermal evaporator
    Zanetti, Emanuele
    Azzolin, Marco
    Girotto, Sergio
    Del Col, Davide
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [32] Experimental Investigation of a Concentrating Bifacial Photovoltaic/Thermal Heat Pump System with a Triangular Trough
    Dolgun, Guelsah Karaca
    Guler, Onur Vahip
    Georgiev, Aleksandar G. G.
    Kecebas, Ali
    ENERGIES, 2023, 16 (02)
  • [33] Characteristics analysis of the photovoltaic thermal heat pump system on refrigeration mode: An experimental investigation
    Liang, Ruobing
    Zhou, Chao
    Zhang, Jili
    Chen, Jianquan
    Riaz, Ahmad
    RENEWABLE ENERGY, 2020, 146 : 2450 - 2461
  • [34] Analysis of the influencing factors in energy efficiency of water loop heat pump systems
    Ma, Zuiliang
    Cao, Yuan
    1997, (25):
  • [35] Numerical investigation of PVT coverage on an integrated building-solar-heat pump system: Technical and economic study
    Bisengimana, Emmanuel
    Zhou, Jinzhi
    Binama, Maxime
    Nyiranzeyimana, Gaudence
    Yuan, Yanping
    SOLAR ENERGY, 2023, 249 : 507 - 520
  • [36] Numerical investigation on the performance and environmental aspect of roll bond photovoltaic thermal unit condenser incorporating fins on the absorber
    Basalike, Pie
    Peng, Wang
    Zhang, Jili
    Lu, Shixiang
    ENERGY, 2022, 252
  • [37] NUMERICAL INVESTIGATION OF RELIABILITY OF PUMP SYSTEMS FROM THERMAL POWER PLANTS
    Bugatekin, Ayse T.
    THERMAL SCIENCE, 2018, 22 : S137 - S142
  • [38] A systematic review of recent air source heat pump (ASHP) systems assisted by solar thermal, photovoltaic and photovoltaic/thermal sources
    Wang, Xinru
    Xia, Liang
    Bales, Chris
    Zhang, Xingxing
    Copertaro, Benedetta
    Pan, Song
    Wu, Jinshun
    RENEWABLE ENERGY, 2020, 146 (146) : 2472 - 2487
  • [39] Numerical investigation of high temperature heat pump integrated hybrid cooling system
    Koundinya, Sandeep
    Seshadri, Satyanarayanan
    Hafner, Armin
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [40] Numerical study on the heat transfer limits of a novel dual-condenser heat pipe integrated with photovoltaic/thermal (PV/T) system
    Ji, Yasheng
    Yuan, Yanping
    Zhao, Kaiming
    Ji, Wenhui
    Zhou, Jinzhi
    RENEWABLE ENERGY, 2023, 218