Monte Carlo modelling of Germanium detectors for the measurement of low energy photons in internal dosimetry: Results of an international comparison

被引:25
|
作者
Gomez-Ros, J. M.
de Carlan, L.
Franck, D.
Gualdrini, G.
Lis, M.
Lopez, M. A.
Moraleda, M.
Zankl, M.
Badal, A.
Capello, K.
Cowan, P.
Ferrari, P.
Heide, B.
Henniger, J.
Hooley, V.
Hunt, J.
Kinase, S.
Kramer, G. H.
Loehnert, D.
Lucas, S.
Nuttens, V.
Packer, L. W.
Reichelt, U.
Vrba, T.
Sempau, J.
Zhang, B.
机构
[1] CIEMAT, E-28040 Madrid, Spain
[2] CEA, DRT LIST DETECS LNHB LMD, F-91191 Gif Sur Yvette, France
[3] IRSN, DRPH SDI LEDI, F-92262 Fontenay Aux Roses, France
[4] ION IRP, ENEA, I-40136 Bologna, Italy
[5] GSF, Natl Res Ctr Environm & Hlth, D-85764 Neuherberg, Germany
[6] UPC, Inst Tech Energet, Barcelona 08028, Spain
[7] Serco Assurance, Ctr Winfrith, Dorchester DT2 8DH, Dorset, England
[8] Forschungszentrum Karlsruhe, D-76344 Eggenstein Leopoldshafen, Germany
[9] Tech Univ Dresden, D-01062 Dresden, Germany
[10] Inst Radioprotecao & Dosimetria, Rio de Janeiro, Brazil
[11] Japan Atom Energy Agcy, Tokai, Ibaraki 3191195, Japan
[12] Univ Namur, LARN Lab, B-5000 Namur, Belgium
[13] AWE, Dosimetry & Radiol Metrol Serv, Aldermaston RG7 4PR, Berks, England
[14] NRPI, Prague 10000 10, Czech Republic
关键词
Ge detectors; Monte Carlo simulations; voxel phantoms; internal dosimetry; PHANTOM;
D O I
10.1016/j.radmeas.2007.12.023
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This communication summarizes the results concerning the Monte Carlo (MC) modelling of Germanium detectors for the measurement of low energy photons arising from the "International comparison on MC modelling for in vivo measurement of Americium in a knee phantom" organized within the EU Coordination Action CONRAD (Coordinated Network for Radiation Dosimetry) as a joint initiative of EURADOS working groups 6 (computational dosimetry) and 7 (internal dosimetry). MC simulations proved to be an applicable way to obtain the calibration factor that needs to be used for in vivo measurements. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:510 / 515
页数:6
相关论文
共 50 条
  • [21] Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source
    Bouzid, Dounia
    Bert, Julien
    Dupre, Pierre-Francois
    Benhalouche, Saadia
    Pradier, Olivier
    Boussion, Nicolas
    Visvikis, Dimitris
    ACTA ONCOLOGICA, 2015, 54 (10) : 1788 - 1795
  • [22] Small Field Dosimetry Comparison of a Sub-Mm Plastic Scintillator to Silicon Diode Detectors Measurements and Monte Carlo Calculations
    Northern, E.
    BaradaranGhahfarokhi, M.
    Cooney, A.
    Ding, G. X.
    Luo, G.
    Homann, K. L.
    MEDICAL PHYSICS, 2024, 51 (09) : 6623 - 6623
  • [23] Low-energy photons in high-energy photon fields - Monte Carlo generated spectra and a new descriptive parameter
    Chofor, Ndimofor
    Harder, Dietrich
    Willborn, Kay
    Ruehmann, Antje
    Poppe, Bjoern
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (03): : 183 - 197
  • [24] Monte Carlo modelling for in vivo measurements of americium in a knee voxel phantom:: General criteria for an international comparison
    Gomez-Ros, J. M.
    de Carlan, L.
    Franck, D.
    Gualdrini, G.
    Lis, M.
    Lopez, M. A.
    Moraleda, M.
    Zankl, M.
    RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) : 245 - 248
  • [25] Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization
    Cranmer-Sargison, G.
    Weston, S.
    Evans, J. A.
    Sidhu, N. P.
    Thwaites, D. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (16): : 5141 - 5153
  • [26] Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation
    Wijesooriya, K.
    Liyanage, N.
    Kaluarachchi, M.
    Sawkey, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3615 - 3615
  • [27] Application of diamond detectors to the dosimetry of 45 and 100 kVp therapy beams: comparison with a parallel-plate ionization chamber and Monte Carlo
    Hugtenburg, RP
    Johnston, K
    Chalmers, GJ
    Beddoe, AH
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2489 - 2501
  • [28] Tungsten carbide and LMPA electron cutouts: comparison and validation using Monte Carlo modelling and measurement of dose
    Leat, Christopher J.
    Ramachandran, Prabhakar
    Langton, Christian M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (01)
  • [29] Measurement Comparison and Monte Carlo Simulations for RapidArc Delivery Verification using ArcCheck 4D Dosimetry System
    Koren, S.
    Lin, M.
    Fan, J.
    Wang, L.
    Cherian, G.
    Price, R. A.
    Ma, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S737 - S738
  • [30] A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations
    Turner, Adam C.
    Zhang, Di
    Kim, Hyun J.
    DeMarco, John J.
    Cagnon, Chris H.
    Angel, Erin
    Cody, Dianna D.
    Stevens, Donna M.
    Primak, Andrew N.
    McCollough, Cynthia H.
    McNitt-Gray, Michael F.
    MEDICAL PHYSICS, 2009, 36 (06) : 2154 - 2164