Monte Carlo modelling of Germanium detectors for the measurement of low energy photons in internal dosimetry: Results of an international comparison

被引:25
|
作者
Gomez-Ros, J. M.
de Carlan, L.
Franck, D.
Gualdrini, G.
Lis, M.
Lopez, M. A.
Moraleda, M.
Zankl, M.
Badal, A.
Capello, K.
Cowan, P.
Ferrari, P.
Heide, B.
Henniger, J.
Hooley, V.
Hunt, J.
Kinase, S.
Kramer, G. H.
Loehnert, D.
Lucas, S.
Nuttens, V.
Packer, L. W.
Reichelt, U.
Vrba, T.
Sempau, J.
Zhang, B.
机构
[1] CIEMAT, E-28040 Madrid, Spain
[2] CEA, DRT LIST DETECS LNHB LMD, F-91191 Gif Sur Yvette, France
[3] IRSN, DRPH SDI LEDI, F-92262 Fontenay Aux Roses, France
[4] ION IRP, ENEA, I-40136 Bologna, Italy
[5] GSF, Natl Res Ctr Environm & Hlth, D-85764 Neuherberg, Germany
[6] UPC, Inst Tech Energet, Barcelona 08028, Spain
[7] Serco Assurance, Ctr Winfrith, Dorchester DT2 8DH, Dorset, England
[8] Forschungszentrum Karlsruhe, D-76344 Eggenstein Leopoldshafen, Germany
[9] Tech Univ Dresden, D-01062 Dresden, Germany
[10] Inst Radioprotecao & Dosimetria, Rio de Janeiro, Brazil
[11] Japan Atom Energy Agcy, Tokai, Ibaraki 3191195, Japan
[12] Univ Namur, LARN Lab, B-5000 Namur, Belgium
[13] AWE, Dosimetry & Radiol Metrol Serv, Aldermaston RG7 4PR, Berks, England
[14] NRPI, Prague 10000 10, Czech Republic
关键词
Ge detectors; Monte Carlo simulations; voxel phantoms; internal dosimetry; PHANTOM;
D O I
10.1016/j.radmeas.2007.12.023
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This communication summarizes the results concerning the Monte Carlo (MC) modelling of Germanium detectors for the measurement of low energy photons arising from the "International comparison on MC modelling for in vivo measurement of Americium in a knee phantom" organized within the EU Coordination Action CONRAD (Coordinated Network for Radiation Dosimetry) as a joint initiative of EURADOS working groups 6 (computational dosimetry) and 7 (internal dosimetry). MC simulations proved to be an applicable way to obtain the calibration factor that needs to be used for in vivo measurements. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:510 / 515
页数:6
相关论文
共 50 条
  • [1] Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise
    Zankl, Maria
    Gomez-Roy, Jose-Maria
    Moraleda, Montserrat
    Reichelt, Uwe
    Akar, Deepak K.
    Borbinha, Jorge
    Desorgher, Laurent
    Di Maria, Salvatore
    EL Bakkali, Jaafar
    Fantinova, Karin
    Ferrari, Paolo
    Gossio, Sebastian
    Hunt, John
    Jovanovic, Zoran
    Kim, Han Sung
    Krstic, Dragana
    Lee, Yi-Kang
    Nadar, Minal Y.
    Nikezic, Dragoslav
    Patni, Hemant K.
    Murugan, Manohari
    Trivin, Sebastian
    RADIATION MEASUREMENTS, 2021, 148
  • [2] THE APPLICATION OF GERMANIUM DETECTORS FOR INVIVO COUNTING OF LOW-ENERGY PHOTONS
    BOOTH, LF
    GROFF, DW
    BRONSON, FL
    HEALTH PHYSICS, 1987, 52 : S58 - S58
  • [3] Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison
    Broggio, D.
    Bento, J.
    Caldeira, M.
    Cardenas-Mendez, E.
    Farah, J.
    Fonseca, T.
    Konvalinka, C.
    Liu, L.
    Perez, B.
    Capello, K.
    Cowan, P.
    Cruzate, J. -A.
    Freire, L.
    Gomez-Ros, J. -M.
    Gossio, S.
    Heide, B.
    Huikari, J.
    Hunt, J.
    Kinase, S.
    Kramer, G. H.
    Kurihara, O.
    Kyrieleis, A.
    Lebacq, A. -L.
    Leone, D.
    Li, C.
    Li, J.
    Mihailescu, L. -C.
    Moraleda, M.
    Navarro, J. -F.
    Oliveira, C.
    Puerta, N.
    Reichelt, U.
    Simoes, C.
    Sommer, D.
    Takahashi, M.
    Teles, P.
    Vanhavere, F.
    Vrba, T.
    Franck, D.
    Gualdrini, G.
    Lopez, M. -A.
    RADIATION MEASUREMENTS, 2012, 47 (07) : 492 - 500
  • [4] MONTE-CARLO CALCULATION OF ENERGY RESOLUTION OF LEAD GLASS DETECTORS FOR HIGH-ENERGY PHOTONS
    HANIN, VA
    STERN, BE
    NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (03): : 455 - 460
  • [5] Dosimetry of small beams used in radiosurgery: A comparison between different detectors and Monte Carlo simulation
    Francescon, P
    Cavedon, C
    Cora, S
    Stancanello, J
    Scalchi, P
    Avanzo, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2004 - 2004
  • [6] Comparison of Monte Carlo-simulated scattering processes of low-energy photons in radiation detector materials
    Cibulskait, I.
    Adliene, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 73 - 76
  • [7] Monte Carlo simulation study on the cause of the formation of the efficiency curve at low energies in germanium detectors
    Aksoy, Gulper
    Unlu, Hasan
    Bolukdemir, Mustafa Hicabi
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [8] The sensitivity of LaBr3:Ce scintillation detectors to low energy neutrons: Measurement and Monte Carlo simulation
    Tain, J. L.
    Agramunt, J.
    Algora, A.
    Aprahamian, A.
    Cano-Ott, D.
    Fraile, L. M.
    Guerrero, C.
    Jordan, M. D.
    Mach, H.
    Martinez, T.
    Mendoza, E.
    Mosconi, M.
    Nolte, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 774 : 17 - 24
  • [9] Monte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models
    Ghiasi, H.
    Mesbahi, A.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2010, 8 (03): : 187 - 193
  • [10] An evaluation of germanium detectors employed for the measurement of radionuclides deposited in lungs using an experimental and Monte Carlo approach
    Webb, JL
    Kramer, GH
    HEALTH PHYSICS, 2001, 81 (06): : 711 - 719